header advert
Results 21 - 40 of 65
Results per page:
Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_7 | Pages 12 - 12
1 May 2018
Hart S Wood A Murray J
Full Access

High tibial osteotomy (HTO) is largely conducted as an inpatient procedure, imposing the significant cost of hospital admission. Here we examine patient-related outcomes and cost benefit of altering HTO to a day-case procedure.

A retrospective questionnaire was conducted with patients that underwent HTO in the one and half years prior to the change to day-case, and those in the one and half years afterwards. We considered pre-operative and post-operative KOOS scores, patient pain-scoring and whether they would, given their experience, undergo HTO as an outpatient again.

Thirty-three patients were included in the trial: twenty-three inpatient admissions and ten day-cases.

Average KOOS score improvement for inpatients was 24.68 and outpatients was 31.8. Outcomes such as post-operative pain and nausea/vomiting were found to be similar between groups. The outpatient group unanimously agreed that if undergoing HTO again they would desire to be treated in the outpatient setting again.

Currently HTO is conducted as an inpatient procedure in the majority of institutions. We have demonstrated that patients have comparable outcomes and agree that if undergoing HTO again they would wish to do so as day-case outpatient. This represents a significant cost saving for institutions conducting HTO as well as an improvement in service.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 77 - 77
1 Nov 2016
Murray J Leclerc A Pelet S
Full Access

The traditional treatment for a primary anterior shoulder dislocation has been immobilisation in a sling with the arm in adduction and internal rotation. The recurrence rates after the initial traumatic event range from 20% to 94%. However, recent results have suggested that recurrent instability after primary shoulder dislocation may be reduced with immobilisation in external rotation. Since then, controversy exists regarding the position of immobilisation following these injuries. The objective of the present study was to compare immobilisation in internal and external rotation after a primary anterior shoulder dislocation.

Fifty patients presenting to our fracture clinic with a primary traumatic anterior dislocation of the shoulder were randomly assigned to treatment with immobilisation in either internal rotation (IR; 25 patients) or external rotation (ER; 25 patients) for three weeks. In addition of a two-years clinical follow-up, patients underwent a magnetic resonance imaging (MRI) of the shoulder with intra-articular contrast within four days following the traumatic event, and then at three months of follow-up. The primary outcome was a recurrent dislocation within 24 months of follow-up. The secondary outcome was the healing rate of the labral lesion seen on MRI (if present) within each immobilisation group.

The follow-up rate after two years was 92% (23 of 25) in the IR group and 96% (24 of 25) in the ER group. The recurrence rate in the IR group (11 of 23; 47.8%) was higher than that in the ER group (7 of 24; 29.2%) but the difference did not reach statistical significance (p=0.188). However, in the subgroup of patients aged 20–40 years, the recurrence rate was significantly lower in the ER group (3 of 17; 6.4%) than that in the IR group (9 of 18; 50%, p<0,01). In the subgroup of patients with a labral lesion present on the initial MRI, the healing rate of the lesion was 46.2% (6 of 13) in the IR group and 60% (6 of 10) in the ER group (p=0.680). Overall, the recurrence rate among those who showed healing of the labrum (regardless of the immobilisation group) was 8.3% (1 of 12), but patients who did not healed their labrum had a recurrence rate of 45.5% (5 of 11; p=0.069).

This study suggests that immobilisation in ER reduces the risk of recurrence after a primary anterior shoulder dislocation in patients aged between 20 and 40 years. At two years follow-up, the recurrence rate is lower in patients who demonstrated a healed labrum at three months, regardless of the position of immobilisation. Future studies are required in order to identify factors that can improve healing of the damaged labrum following a traumatic dislocation of the shoulder.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_7 | Pages 10 - 10
1 May 2015
Barksfield R Porteous A Robinson J Murray J
Full Access

A key theme of the GIRFT project is centralisation of complex orthopaedic procedures to “Specialist Units” and minimum surgeon volumes. We aimed to estimate the effects of implementing minimum unit and surgeon specific volumes upon orthopaedic units within the Severn region.

Practice profiles for surgeons and units were generated using the NJR Surgeon and Hospital Profile Database. Minimum volume thresholds were set at 13 procedures/year for surgeons and 30 procedures/year for units.

Median surgeon volumes were 33 (range 2–180) for primary TKR, 10 (range 2 – 64) for UKR, 2 (range 2 – 41) for PFJR and 5 (range 2–57) for Revision TKR. Amongst 48 surgeons performing UKR, 26 (54%) performed less than 13 procedures per year accounting for 108 (14%) procedures. Amongst 20 surgeons performing PFJR, 19 (95%) performed <13/year, accounting for 56 (58%) of cases. 49 Surgeons performed revision TKR with 24 (49%) performing <13 revisions per annum, accounting 151 (36%) procedures.

Amongst 16 units performing UKR, 8 (50%) performed <30/year, accounting for 16% overall. Revision TKR was performed in 15 units whilst 8 (53%) performed <30/year, accounting for 62 (15%) cases. We invite discussion of the ramifications of minimum surgeon and unit volumes for Orthopaedic services in the Severn Region.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_7 | Pages 4 - 4
1 May 2015
Metcalfe A Hassaballa M Gill N Ackroyd C Murray J Porteous A Eldridge J
Full Access

The aim of this study was to document the survivorship and patient reported outcome of the Avon patello-femoral replacement in a consecutive series with follow up of 10 years or more.

All cases performed in Bristol from 1996 onwards were prospectively recorded. Follow up was at 1,2,5,7,10,12 and 15 years with the Bristol Patella Score, the Oxford and WOMAC scores and SF12. Implant survival was analysed using the Kaplan-Meier method.

There were 323 PFJ replacements (280 individuals). Follow up was available for 286 cases in 250 patients (89% follow up). The 10 year survival rate was 77%, falling to 67% at 15 years. The most common reason for revision was tibio-femoral progression (45/74 revisions), with loosening or polyethylene wear recorded in 8 cases. The best results were seen in the youngest and the oldest patients. Good improvements were seen in PROMs, with the mean OKS improving from 19.5 to 34.1 at 2 years and 32.7 at the 15 years.

The Avon patello-femoral knee replacement is a successful long-term treatment for isolated patello-femoral knee osteoarthritis, although further improvements are expected in subsequent series, particularly as indications for surgery have evolved over time.


Recent National Institute for Health and Care Excellence (NICE) guidance has advised against the continued use of the Thompson implant when performing hip hemiarthroplasty and recommended surgeons consider using the anterolateral surgical approach over a posterior approach.

Our objective was to review outcomes from a consecutive series of Thompson hip hemiarthroplasty procedures performed in our unit and to identify any factors predicting the risk of complications.

807 Thompson hip hemiarthroplasty cases performed between April 2008 and November 2013 were reviewed. 721 (89.3%) were cemented and 86 (10.7%) uncemented. 575 (71.3%) were performed in female patients. The anterolateral approach was performed in 753 (93.3%) and the posterior approach with enhanced soft tissue repair in 54 (6.7%).

Overall, there were 23 dislocations (2.9%). Dislocation following the posterior approach occurred in 13.0% (7 of 54) in comparison to 2.1% (16 of 753) with the anterolateral approach (odds ratio (OR) 8.5 (95% CI 2.8 to 26.3) p < 0.001). Surgeon grade and patient history of cognitive impairment did not have a significant impact on dislocation rate.

Patients were discharged home in 459 cases (56.9%), to a care home or other hospital in 273 cases (33.8%). 51.8% (338 of 653) returned home within 30 days. 75 died during their admission (9.3%). 30-day mortality was 7.1% and 1-year mortality was 16.6%.

Intraoperative fracture occurred in 15 cases (1.9%) of which 14 were cemented. Superficial or deep infection occurred in 33 cases (4.1%).

We recommend against the continued use of the posterior approach in hip hemiarthroplasty, as enhanced soft tissue repair did not reduce dislocation rates to an acceptable level. Our findings, however, demonstrate satisfactory results for patients treated with the Thompson hip hemiarthroplasty performed through an anterolateral approach. We suggest that the continued use of the Thompson implant in a carefully selected patient cohort is justifiable.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_5 | Pages 3 - 3
1 Mar 2014
Mihok P Bex C Hassaballa M Robinson J Murray J Porteous A
Full Access

Total knee arthoplasty (TKA) remains a standard treatment for advanced knee arthritis. The aim of the procedure is to restore function and relieve pain ideally for the rest of patient's life. Patient matched templating (PMT) or patient specific instrumentation (PSI) is a recent development for alignment of TKA components that uses disposable guides. The users of PSI claim it to be the optimum balance of new technology and conventional technique by reducing the complexity of conventional alignment and sizing tools.

To assess the clinical and radiological outcome of Primary TKA done with PSI.

More than 200 cases of TKA have been done in our unit using PSI and we analysed the radiographic outcome of these cases postoperatively. We also reviewed the clinical outcome of 103 patients with 1 year and 43 patients with 2 year follow-up. Data was collected prospectively: pre-operatively and at 1 year and 2 years post-operatively including Oxford knee score (OKS), WOMAC and American knee society score (AKS). Standard AP and lateral films were done pre-operatively and post-operatively.

Mean age was 66 years. There were 56 female and 47 male patients. Mean post-operative angles on standard films were: Alpha = 95.6, Beta = 88.4, Saggittal femur = 3.4 and Saggittal tibia = 90.8. Of the 103 cases with 1 year follow-up, there was significant improvement in all clinical outcome scores. Mean OKS improved from 18 to 39 at 1 year and remained the same at 2 years, WOMAC improved from 40 to 18 in both 1 and 2 years post-op. AKS Total improved from 79 to 173 at 1 year and 170 at 2 years.

Performing TKA using PSI is safe and provides good radiological alignment in the coronal and sagittal plane. Significant improvement in outcome scores were seen at one and two year follow up and reached levels that compared favourably with other reported series of TKA outcome from our unit.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_5 | Pages 2 - 2
1 Mar 2014
Mihok P Hassaballa M Robinson J Porteous A Bowker K Lovering A Murray J
Full Access

It has been reported that some of the local anaesthetic agents possess antimicrobial activity against clinically-significant bacteria. Although bupivacaine exhibits a bacteriostatic effect at concentrations above 0.25% there are concerns that it might interact with some of the other antibiotics administered to patients. Whilst these interactions may be potentially benign, the risk is that they are antagonistic and that local bupivacaine might predispose the patient to a higher risk of infection.

Bupivacaine is commonly administered as a local anaesthetic following knee arthroplasy; the purpose of this study was to assess its potential interactions with gentamicin eluting from the cement used to fix the device.

A strain of Saphylococcus aureus (29213) with established susceptible Minimal Inhibition Concentration (MIC) and Minimal Bactericidal Concentration (MBC) for gentamicin was used. This organism was inoculated into four types of broth; Mueller-Hinton broth (MH), MH with different concentrations of gentamicin, MH with 0.25% and 0.125% bupivacaine and MH with various combinations of gentamicin and bupivacaine. The broths were incubated at 37C and at 0.5, 1, 2, 3, 6 and 24 hours post inoculation the number of bacteria remaining were counted. From these data kill-curves were generated describing the absolute and individual rates of killing seen with bupivacaine and gentamicin alone and when in combination.

Bupivacaine showed a bacteriostatic effect only at concentrations of 0.25% and higher. All concentrations of gentamicin above or equal to the expected MBC showed bactericidal effect. However, in combination with both strengths of Bupivacaine (0.25 and 0.125%) the bacteriocidal effect of gentamicin was seen at a lower concentration and the rate of killing of bacteria was enhanced.

Bupivacaine has bacteriostatic effect at concentrations above 0.25% in line with published data. In these experiments we have shown that the use of bupivacaine together with gentamicin does not reduce the bactericidal property of the antibiotic and that the bactericidal effect of gentamicin appears to be enhanced by bupivacaine. This would suggest that the local use of bupivacaine is unlikely to increase the risk of infection in patients undergoing knee arthroplasty and may actually be beneficial.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_5 | Pages 5 - 5
1 Mar 2014
Hassaballa M Artz N Mihok P Chapman L Robinson J Porteous A Murray J
Full Access

This is a prospective review of consecutive patients who underwent knee revision surgery using the Legion knee system.

Clinical and functional assessments (American Knee Scores-AKS, WOMAC and Oxford knee score-OKS) were carried out preoperatively, one year and 2 years post op. Radiographic evaluation was done at 1 and 2 years included review of standing AP, lateral and skyline views. Figgie's method was used to measure the joint line reproduction.

210 patients underwent revision knee system 103 male: 107 females with a mean age of 66.4 (44–87) yrs. Mean BMI-26.03 (21–50). We had a 2-year follow up for 110 patients. Surgery was carried out at a single centre and performed by Bristol knee specialists.

Indications for surgery were aseptic loosening (84), infection (27) instability (47), pain and stiffness (31), progression of disease (6), peri-prosthetic fractures (15)

The AKS and WOMAC scores at, 1 year and 2 years follow up showed significant improvements in pain and function. The mean total AKS improved from 75.7/200 pre-operatively to 140.5/200 at 2 yrs. Radiographic assessment showed a mean AP coronal femoral angle of 95.3 degrees (89.6–99.9), coronal tibial angle of 90.1 degrees (88–92). The mean sagittal femoral and tibial angles were 88.4 and 90.4 degrees respectively.

The short-term results showed significant improvement in functional and pain scores irrespective of indications for revision surgery. The Legion system has showed good outcome scores that match or beat published series on revisions. It also showed a good ability to restore joint line.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 33 - 33
1 Mar 2013
Porteous A Murray J Robinson J Hassaballa M
Full Access

Aim

To assess the clinical outcome at 1 year of 30 cases of primary TKA performed with PMCB.

Method

Data was collected prospectively pre-operatively on over 100 primary TKA's performed with PMCB. Of these cases, 30 have reached a point of 1 year follow-up. Validated outcome measures including American Knee Society score, Oxford Knee Score and WOMAC were completed pre-operatively and at 1 year. Radiographic analysis of alignment was performed.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 41 - 41
1 Mar 2013
Porteous A Ansari A Murray J Eldridge J
Full Access

Aim

To analyse the available rotating hinge knee implants available on the market with a view to deriving a rational algorithm for implant selection.

Method

Information on available hinge designs was gathered from the literature and further questionnaires were sent to the relevant implant companies asking for more specific information regarding the minimum bone resection necessary to accommodate the implant, the maximum bone loss that can be compensated with augments, method of transmission of forces, type and size of stems, availability of metaphyseal-filling cones and cost.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 42 - 42
1 Mar 2013
Porteous A Gbedjuade H Murray J Hassaballa M
Full Access

Aim

To assess the outcome and complication rate of rotating hinge knee prostheses in our unit.

Method

From our knee database we have identified 137 consecutive rotating hinged TKRs (implanted 2004–2010) for severe instability, arthrofibrosis and severe bone loss in either primary or revision arthroplasty. Prospective pre-operative scores and post-operative scores were obtained. 23 had died or were lost to follow-up. This left 114 cases with complete outcome and complication data.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 43 - 43
1 Mar 2013
Porteous A Murray J Robinson J Hassaballa M
Full Access

Objectives

The aim of this study was to study the short to medium term outcome of a contemporary modular revision knee system used in our centre for managing knee revision arthroplasty.

Methods

Between July 2006 and October 2011, 153 revision cases were done using the Legion revision system. Seventy eight cases completed a 2 years follow up. Preoperative, one and two years follow up scores and radiographic analysis were recorded. Outcome measures included the American Knee Society (AKSS), Oxford (OKS) and WOMAC scores. The American knee society radiographic analysis system was employed to assess assessment standing AP, lateral and skyline views. Figgie's method was used to measure the joint line reproduction. A difference of 5 mm (pre=op/post-op) was deemed satisfactory.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 31 - 31
1 Mar 2013
Porteous A Murray J Robinson J Hassaballa M
Full Access

Aim

To assess the process of using patient matched cutting blocks in Primary TKA with respect to: radiology, the proposed engineering plans, the process in theatre and cost effectiveness. Background: Patient matched cutting blocks (PMCB) are the subject of much interest in primary TKA. Our unit has experience of over 100 cases with a single system.

Method

We have analysed our initial experience with PMCB. We have compared the sizes of implants used in theatres versus the sizes predicted on the image-generated plans. We have assessed the potential time saving in theatre, during each case and in the turn-around time between cases. We have also looked at the number of trays of instruments used in PMCB versus non-PMCB cases.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 34 - 34
1 Mar 2013
Porteous A Murray J Robinson J Wilson R
Full Access

Aim

To assess the accuracy of predicted and actual cut alignment from PMCB versus intra-operative computer navigation.

Method

We performed 10 primary TKA cases in which both PMCB and computer navigation were used. Standard imaging was performed to generate the plan and the cutting blocks to perform the case with PMCB. At the start of the case, standard navigation procedure was followed using the Praxim navigation system to register the centre of the femoral head, femoral and tibial surfaces and alignment. The PMCB were applied to the femur and tibia and the navigation cut-registering shim was placed in the slot on the PMCB to record the position and alignment of the proposed cut in the coronal and sagittal planes. The following parameters were compared: overall limb alignment in the coronal plane, distal femoral coronal angle, depth of resection on medial and lateral distal femoral condyle and depth of resection on medial and lateral proximal tibia. Differences in the pre-operative PMCB plan, intra-operative navigation assessment and proposed cuts after application of the blocks intra-operatively were recorded.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 46 - 46
1 Mar 2013
Porteous A Sullivan N Murray J Eldridge J
Full Access

Aim

To assess if there is a reproducible relationship between the width and thickness of the normal patella.

Method

43 MRI scans of young adults, average age 27 (range 17–38) were studied. Exclusion criteria included a diagnosis of degenerative joint disease, patella-femoral pathology or age under 16/over 40 (102 patients). The bony thickness of the patella, the chondral thickness and patella width were measured, as was the location of maximal patella thickness. Inter/intra observer variability was calculated and correlation analysis performed.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 44 - 44
1 Mar 2013
Porteous A Murray J Robinson J Hassaballa M
Full Access

Aim

To assess the survivorship of unicompartmental replacements (UKR) revised to UKR. Background: Partial revision of UKR, or revision to a further UKR is a rarely performed procedure with some data from the Australian registry suggesting that results are not good, with early revision being required.

Method

All revision procedures from initial UKR are prospectively followed and scored as part of our department's knee database. We analysed the 37 cases in our database that showed revision of UKR to UKR. These included cases in the following categories: a) Mobile bearing revised to mobile bearing (n=8) b) Mobile bearing revised to fixed bearing (n=20) c) Fixed bearing revised to fixed bearing (n=9)


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_9 | Pages 3 - 3
1 Feb 2013
Gbejuade H Hassaballa M Robinson J Porteous A Murray J
Full Access

The gold standard for measuring knee alignment is the lower limb mechanical axis. This is traditionally assessed by weight-bearing full length lower limb X-rays (LLX). CT scanograms (CTS) are however, becoming increasingly popular in view of lower radiation exposure, speed and supine positioning. We assessed the correlation and reproducibility of knee joint coronal alignment using these two imaging modalities.

LLX and CTS images were obtained in 24 knees with degenerate joint disease or failed TKR. Hip to ankle mechanical alignment were measured using the PACS software. Coronal knee alignment was assessed from the centre of the knee, measuring the valgus/varus angle relative to the mechanical axis. Measurements were made by two orthopaedic surgeons (Research Fellow and Consultant) on two separate occasions.

The mean alignment angles measured by observers 1 and 2 on CTS were 180.29° (SD 6.04) and 180.71° (SD 6.13) respectively, while on LLX were 181.04° (SD7.58) and 181.04° (SD 7.72). The measurements between the two observers were highly correlated for both the CTS (r = 0.97, p < 0.001) and the LLX (r = 0.99, p < 0.001). The angles measured on CTS and LLX were highly correlated (r = 0.826, p < 0.001) with high degree of internal consistency (ICC = 0.804). Malalignment of greater than 5° was seen in 19% of the CTS and 35% of the LLX.

There was good correlation between CT scanogram and weight-bearing X-ray measurements in normally-aligned knees. However, as expected, in the malaligned lower limb, the influence of weight-bearing is critical which demonstrates the significance of weight-bearing X-rays.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_9 | Pages 4 - 4
1 Feb 2013
Sullivan N Robinson P Ansari A Hassaballa M Porteous A Robinson J Eldridge J Murray J
Full Access

Patello-femoral arthritis can result in a considerable thinning of the patella. The restoration of an adequate patella thickness is key to the successful outcome of knee arthroplasty.

The objectives were (1) to establish a reproducible patella width:thickness index including chondral surface and (2) to investigate whether there is a difference between bone alone and bone/chondral construct thickness as shown by MRI.

Forty three MRI scans of young adults, mean age 27 (range 17–38), 34 male and 9 female, were studied. Exclusion criteria included degenerative joint disease, patello-femoral pathology or age under 16/over 40 (102 patients). The bony and chondral thickness of the patella and its width were measured. Inter/intra observer variability was calculated and correlation analysis performed.

We found a strong correlation between patella plus cartilage thickness and width (Pearson 0.75, P < 0.001). The mean width:thickness ratio was 1.8 (SD 0.10, 95% CI 1.77–1.83). Without cartilage the ratio was 2.16 (SD 0.15, 95% CI 2.11–2.21), correlation was moderate (Pearson 0.68, P < 0.001). The average patella cartilage thickness was 4.1mm (SD 1.1, 95% CI 3.8–4.5).

The narrow confidence intervals for the ratio of patella width:thickness suggest that patella width can be used as a guide to accurate restoration of patella thickness during total knee or patella-femoral replacement. We would recommend a ratio of 1.8:1.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_9 | Pages 20 - 20
1 Feb 2013
Tasker A Hassaballa M Lancaster S Murray J Porteous A
Full Access

We present a prospective, randomised, single-centre, multi-surgeon, controlled trial comparing minimally invasive (MIS) and standard approach total knee arthroplasty (TKA).

86 patients undergoing 92 total knee replacements were recruited. 46 operations were randomised to the MIS treatment arm, 46 to the standard control arm. Data collected included postoperative blood loss, length of stay and complications. Patients underwent surgery via a quadriceps sparing or standard medial parapatella approach. All operations were performed using MIS instruments and an identical postoperative care pathway.

The MIS group had a significantly shorter length of stay (1.4 days, p=0.004) and fewer complications (p=0.003). Demographics, operative time blood loss and radiographic alignment were comparable between the groups. There were no deaths, pulmonary emboli or surgical site infections. 1 patient developed DVT and 1 required revision for pain and failure to regain flexion within 9 months of surgery, both in the control group. Nine percent of MIS patients versus 35% controls suffered a complication delaying discharge, of which 2% and 17% related to surgical site problems respectively.

MIS resulted in a shorter admission and fewer complications, whilst achieving satisfactory component alignment. We discuss the potential economic implications.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 69 - 69
1 Sep 2012
Gbejuade H Hassaballa M Robinson J Murray J Porteous A
Full Access

Introduction

Patients with severe knee instability and extensive bone loss remain a surgical challenge. In such cases, regular knee implants and constrained condylar implants may not be suitable or have been attempted and failed.

Hinged knee replacements have developed an important role in the management of such complex knee cases. They also have an increasingly important role in cases such as rheumatoid arthritis and other cases of severe joint destruction.

We present a review of 138 consecutive hinge knee arthroplasties of 8 different Hinge models performed in our unit between 2004 and 2010.

Method

Combined prospective and retrospective study of 138 (42 primary and 96 revisions) consecutive cases of Hinge knee replacements at a mean follow up of 4.2 years. Outcomes were recorded and scored using the American knee score preoperatively, 1, 2 and 5 years. Complications, re-revisions, implant failures and survivorship were also assessed.