header advert
Results 1 - 20 of 20
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 16 - 16
7 Aug 2023
Arthur L Amin A Rahman A Tu SJ Mellon S Murray D
Full Access

Abstract

Introduction

Anecdotal reports suggest some cementless Oxford Unicompartmental Knee Replacements (OUKRs) have painful early subsidence of the tibial component with valgus rotation and/or posterior tilting. The incidence of subsidence and its association with pain is poorly understood. This radiographic study aimed to evaluate the incidence of tibial subsidence and five-year patient reported outcome measures (PROMs) of a cementless OUKR cohort.

Methodology

Cementless OUKRs from a high-volume centre with acceptable post-operative and five-year radiographs were included. Subsidence was determined by measuring the angle of the tibial tray/tibial axis angle and distance between the tibial tray axis and fibula head on anteroposterior and lateral radiographs using a custom MATLAB program. Analysis of 5-year PROMs assessed the relationship between subsidence and pain. Radiographs indicating tibial subsidence were validated by two observers.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 40 - 40
7 Aug 2023
Rahman A Strickland L Pandit H Jenkinson C Murray D
Full Access

Abstract

Background

Daycase pathways which aim to discharge patients the same day following Unicompartmental Knee Replacement have been introduced in some centres, though most continue with Standard pathways. While Daycase pathways have cost savings, recovery data comparing pathways is limited. This study aims to compare patient-reported early recovery between Daycase and Standard pathways following UKR.

Method

This study was carried out in two centres that originally used the same Standard recovery pathway for UKR. In one centre, the Standard pathway was modified into a Daycase pathway. 26 Daycase-Outpatient, 11 Daycase-Inpatient, and 18 Standard patients were recruited. Patients completed the Oxford Arthroplasty Early Recovery Score (OARS) and SF-36 (Acute) measure between Days 1–42.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 46 - 46
7 Aug 2023
Rahman A Heath D Mellon S Murray D
Full Access

Abstract

Introduction

In cementless UKR, early post-operative tibial fractures are 7x more common in very small tibias. A smaller keel has been shown to reduce this fracture risk, but its effect on fixation is unassessed. This mechanical study assesses the effect of keel interference and size on sagittal micromotion of the tibial component in physiological loading positions.

Method

A high-resolution Digital Image Correlation setup was developed and validated to an accuracy of 50 micrometres. Variants of tibial components were 3D-printed: standard, no-interference, no-keel, and a new small keel. Components were implanted into bone-analogue foam which was machined to a CT-reconstructed small tibia, using surgical technique. Tibias were loaded to 200N in physiological loading positions: 8mm (step-up) and 15mm (lunge) posterior to midpoint, and micromotion was assessed.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 17 - 17
7 Aug 2023
Arthur L Ghosh P Mohammad H Campi S Murray D Mellon S
Full Access

Abstract

Introduction

The Oxford Unicompartmental Knee Replacement's (OUKR's) fully-congruent design minimises polyethylene wear. Consequently, wear is a rare failure mechanism. Phase-3 OUKR linear wear at 5 years was higher than previous OUKR phases, but very low compared to fixed-bearing UKRs. This study aimed to measure OUKR bearing wear at 10 years and investigate factors that may affect wear.

Methodology

Bearing thickness for 39 OUKRs from a randomised study was calculated using radiostereometric analysis at regular intervals up to 10 years. Data for 39 and 29 OUKRs was available at 5 and 10 years, respectively. As creep occurs early, wear rate was calculated using linear regression between 6 months and 10 years. Relationships between wear and patient factors, fixation method, Oxford Knee Score (OKS), bearing position, and component position were analysed.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 16 - 16
1 Jul 2022
Salman L Abudalou A Khatkar H Ahmed G Kendrick B Murray D
Full Access

Abstract

Purpose

Unicompartmental knee arthroplasty (UKA) is an effective treatment for late knee osteoarthritis (OA). However, its indications remain controversial. Young age (< 60 years) has been associated with worse outcomes. The goal of this systematic review and meta-analysis is to study the effect of age on UKA outcomes.

Methods

The primary objective was to compare the UKA revision rate in young patients with that of old patients, using the age thresholds of 60 and 55 years. Secondary objectives were patient-reported outcome measures (PROMs) and implant design. PubMed, Ovid, Web of Science, Google Scholar, and Cochrane library were searched in June 2021. This review was conducted in accordance with the PRISMA guidelines (PROSPERO registration number: CRD42021248322).


Abstract

Introduction

Cementless fixation of Oxford Unicompartmental Knee Replacements (UKRs) is an alternative to cemented fixation, however, it is unknown whether cementless fixation is as good long-term. This study aimed to compare primary and long-term fixation of cemented and cementless Oxford UKRs using radiostereometric analysis (RSA).

Methodology

Twenty-nine patients were randomised to receive cemented or cementless Oxford UKRs and followed for ten years. Differences in primary fixation and long-term fixation of the tibial components (inferred from 0/3/6-month and 6-month/1-year/2-year/5-year/10-year migration, respectively) were analysed using RSA and radiolucencies were assessed on radiographs. Migration rates were determined by linear regression and clinical outcomes measured using the Oxford Knee Score (OKS).


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 85 - 85
1 Jul 2022
Rahman A Heath D Mellon S Murray D
Full Access

Abstract

Introduction

In cementless UKR, primary fixation of the tibial component is achieved by press-fitting a keel (i.e. with interference) into a vertical slot cut into the proximal tibia. This may adversely affect the structural integrity of surrounding bone. Early post-operative peri-prosthetic tibial fractures are 7x more common in very small knees, but the aetiology of these fractures is unknown - such sizes are rarely used in the UK but more common in Asian populations. This study explores the effect of keel-related features in fracture risk of these very small tibias.

Method

This in vitro study compares the effect of keel and slot depth (standard vs 33% shallower vs nil) and loading position (anterior/posterior gait range limits: mid-tibia vs 8mm posterior) on fracture load and path. 3D-printed titanium components were implanted using surgical instrumentation/technique, in bone-analogue foam machined to a CT-reconstructed very small tibia which subsequently experienced a peri-prosthetic fracture.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 84 - 84
1 Jul 2022
Rahman A Dangas K Mellon S Murray D
Full Access

Abstract

Introduction

After remodelling, loss of bone density beside the keel of cementless UKR tibial components has been observed as a potential cause of concern. How this affects patient-reported outcomes, and further clinical implications, is unclear. This study aims to assess the effect of cementless UKR implantation on tibial bone density, and to explore its relationship to patient demographics and outcomes.

Method

This prospective study assesses 115 anterior-posterior radiographs from cementless UKR postoperatively and five years after surgery. Grey values from nine regions around each keel were collected and standardised to enable inter-radiograph comparison. Change between the post-operative and 5-year radiographs (indicating bone density) was calculated, and effect on 5-year patient demographics and pain and functional outcomes was assessed. Repeat measurements were performed by two operators to assess reliability.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 6 - 6
1 Jul 2022
Hamilton T Knight R Stokes J Rombach I Cooper C Davies L Dutton S Barker K Cook J Lamb S Murray D Poulton L Wang A Strickland L Duren BV Leal J Beard D Pandit H
Full Access

Abstract

Introduction

This multi-centre randomised controlled trial evaluated the clinical and cost effectiveness of liposomal bupivacaine for pain and recovery following knee replacement.

Methodology

533patients undergoing primary knee replacement were randomised to receive either liposomal bupivacaine (266mg) plus bupivacaine hydrochloride (100mg) or control (bupivacaine hydrochloride 100mg), administered at the surgical site. The co-primary outcomes were pain visual analogue score (VAS) area under the curve (AUC) 6 to 72hours and the Quality of Recovery 40 (QoR-40) score at 72hours.


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 861 - 867
1 Jul 2020
Hiranaka T Yoshikawa R Yoshida K Michishita K Nishimura T Nitta S Takashiba K Murray D

Aims

Cementless unicompartmental knee arthroplasty (UKA) has advantages over cemented UKA, including improved fixation, but has a higher risk of tibial plateau fracture, particularly in Japanese patients. The aim of this multicentre study was to determine when cementless tibial components could safely be used in Japanese patients based on the size and shape of the tibia.

Methods

The study involved 212 cementless Oxford UKAs which were undertaken in 174 patients in six hospitals. The medial eminence line (MEL), which is a line parallel to the tibial axis passing through the tip of medial intercondylar eminence, was drawn on preoperative radiographs. Knees were classified as having a very overhanging medial tibial condyle if this line passed medial to the medial tibial cortex. They were also classified as very small if a size A/AA tibial component was used.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 102 - 102
1 Jul 2012
van Duren B Pandit H Tilley S Price M Gill H Murray D Thomas N
Full Access

Introduction

Traditional TKR designs exhibit abnormal and unpredictable kinematics: with posterior subluxation in extension and anterior slide with flexion. These can contribute to restricted knee flexion and reduced quadriceps efficiency. Newer designs attempt to provide “guided motion” with the aim of mimicking normal knee kinematics. The Journey (Smith & Nephew) BCS TKR incorporates both an anterior and a posterior cam/post mechanism while Triathlon PS TKR (Stryker) incorporates a posterior cam/post mechanism. This study compares the in-vivo kinematics of these two designs and compares it with normal knee.

Methods

Knee kinematics of 10 patients with Journey-BCS TKR and 11 patients with Triathlon PS TKR; all with excellent clinical outcome (average age: 65) were analysed. Patients underwent fluoroscopic assessment of the knee during a step-up and deep knee bend exercise. 2D fluoroscopic images were recorded. Data was analysed for patella tendon angle (PTA) and contact points using a 3D model fitting technique. This data was compared to normal knee kinematics (n=20).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 92 - 92
1 Jul 2012
Mehmood S Batta V Gulati A Pandit H Bottomley N Gil H Beard D Dodd C Jackson W Murray D Price A
Full Access

INTRODUCTION

Establishing a full-thickness cartilage in the lateral compartment and functionally intact ACL is vital before proceeding with unicompartmental knee replacement (UKR). The aim of this study is to assess whether MRI is a useful adjunct in predicting suitability for UKR, as compared to standard and stress radiographs.

METHODS

We identified 50 patients with a knee found suitable for UKR based on their standard and stress radiographs (full-thickness cartilage on lateral side). These patients underwent an additional cartilage-specific MRI scan to identify the status of ACL and the lateral compartment. The final decision regarding the suitability for UKR was based on the intra-operative observation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 43 - 43
1 Jul 2012
Price A Jackson W Field R Judge A Carr A Arden N Murray D Dawson J Beard D
Full Access

Purpose

The Oxford Knee Score (OKS) is a validated and widely used PROM that has been successfully used in assessing the outcome of knee arthroplasty (KA). It has been adopted as the nationally agreed outcome measure for this procedure and is now routinely collected. Increasingly, it is being used on an individual patient basis as a pre-operative measure of osteoarthritis and the need for joint replacement, despite not being validated for this use. The aim of this paper is to present evidence that challenges this new role for the OKS.

Method

We have analysed pre-operative and post-operative OKS data from 3 large cohorts all undergoing KA, totalling over 3000 patients. In addition we have correlated the OKS to patient satisfaction scores. We have validated our findings using data published from the UK NJR.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 25 - 25
1 Mar 2012
Pandit H Jenkins C Gill H Beard D Price A Dodd C Murray D
Full Access

Introduction

The results of the mobile bearing Oxford unicompartmental knee replacement (UKR) in the lateral compartment have been disappointing with a five year survival of 82%. Therefore, it is recommended that mobile bearings should not be used for lateral UKR. This low survivorship is primarily due to high dislocation rate, all occurring in the first year. A detailed analysis of the causes of bearing dislocation confirmed the elevated lateral tibial joint line to be a contributory factor. A new surgical technique was therefore introduced in which care was taken neither to remove too much bone from distal femur nor to over tighten the knee and thus ensure that the tibial joint line was not elevated. Other modifications to the technique were also introduced including use of a domed tibial component.

Aim

The aim of this study is to compare the outcome of these iterations: the original series [series I], Series II with improved surgical technique and the domed tibial component [Series III].


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 19 - 19
1 Mar 2012
Bottomley N Kendrick B Ferguson J Al-Ali S Dodd C Murray D Beard D Price A
Full Access

Introduction

Total knee arthroplasty (TKA) accounts for 84% of all knee replacement surgery in the UK (NJR 2009) despite published epidemiological data showing that single compartment disease is most prevalent. We investigated this incompatibility further by describing the compartmental pattern and stage of cartilage loss of all patients with osteoarthritis (OA) presenting to a specialist knee clinic over one year.

Methods

All new primary referrals in a calendar year by local General Practitioners to knee clinic at a United Kingdom Hospital were assessed. Tertiary referrals and second opinions were excluded. The final diagnosis after all imaging was recorded and tabulated. The standing AP, lateral and skyline radiographs of all cases of arthritis were scored to assess the pattern of disease.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 34 - 34
1 Mar 2012
Ferguson J Pandit H Price A Marks B Gill H Murray D Dodd C
Full Access

Introduction

Obesity has been considered a relative contra-indication in unicompartmental knee arthroplasty (UKA) due to fear of high wear rates, loosening and tibial collapse. The aim of this study was to investigate the impact of high body mass index (BMI) on ten-year survivorship and five-year functional outcome after Oxford UKA, a fully congruous mobile bearing design with large contact area and low wear rate.

Methods

This prospective study examines a consecutive series of 595 knees (mean age 66 years, range: 33-88) undergoing Oxford UKA with a minimum 5-year follow-up. Patients were divided into three groups; Group I (Normal body weight), BMI <25 (n=171), Group II (overweight), BMI 25- 30 (n=264), and Group III (Obese), BMI ≥30 (n=160). The survivorship and functional outcome (as assessed by change in Oxford Knee Score [DeltaOKS]) and Knee Society Score (KSS) for all three groups were compared.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 32 - 32
1 Mar 2012
Kendrick B Simpson D Bottomley N Kaptein B Garling E Gill H Dodd C Murray D Price A
Full Access

Purpose of study

To investigate the linear penetration rate of the polyethylene bearing in unicompartmental knee arthroplasty at twenty years.

Introduction

The Phase 1 Oxford medial UKR was introduced in 1978 as a design against wear, with a fully congruous articulation. In 1987 the Phase 2 implant was introduced with new instrumentation and changes to the bearing shape. We have previously shown a linear penetration rate (LPR) of 0.02 mm/year at ten years in Phase 2, but that higher penetration rates can be seen with impingement. The aim of this study was to determine the 20 year in-vivo LPR of the Oxford UKR, using Roentgen Stereophotogrammetric Analysis (RSA).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 16 - 16
1 Mar 2012
Rout R Mcdonnell SM Jayadev C Xia Z Murray D Hulley PA Price AJ
Full Access

Aim

This aim of this study was to investigate apoptosis, reactive oxygen species (ROS), and their upstream markers in Anteromedial Gonarthrosis (AMG).

Methods

Ten resection specimens, from patients undergoing unicompartmental knee replacement for AMG, and ten control specimens, collected from vascular disease patients undergoing above knee amputation, were used. Routine histology and immunohistochemical studies were conducted for Terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL), Active Caspase 3, Cytochrome C, Active Bax, Bim, 3-Nitrotyrosine and Forkhead box O3A (FOXO 3A).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 27 - 27
1 Mar 2012
Pandit H Jenkins C Weston-Simons S Ferguson J Popat BM Gibbons M Price A Gill H Dodd C Murray D
Full Access

Introduction

Kozinn and Scott have made recommendations about contra-indications for unicompartmental knee replacement (UKR). They suggest that patients younger than 60, weight > 82 kilograms, patients with exposed bone in patella-femoral compartment or patients who are physically active/perform heavy labour should not be offered a UKR. In addition, chondrocalcinosis is a contra-indication. These strict selection criteria are based on the experience with fixed bearing UKAs and are more intuitive than evidence based. The Oxford UKR has a fully congruous mobile bearing and has been shown to have minimal wear. Over the past 25 years, the Oxford Group has followed a standardised protocol for patient selection for UKR. We ignore patella-femoral joint pathology, chondrocalcinosis, patient's age, weight and activity level when deciding the suitability for UKR.

Methods

Using the standardised indications, more than 1100 Oxford UKRs have been performed to date over the last 10 years. These patients are assessed pre-operatively and at regular intervals post-operatively in a dedicated research clinic. We present the results of these consecutive cases. Patients were classified into two groups: group I (satisfy Kozinn-Scott recommendations) and group II (outside recommendations).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 31 - 31
1 Mar 2012
Kendrick B Pandit H Jenkins C Beard D Gill H Price A Dodd C Murray D
Full Access

Purpose of Study

To assess the incidence of radiolucency in cemented and cementless Oxford unicompartmental knee replacement at two years.

Introduction

Most unicompartmental knee replacements (UKRs) employ cement for fixation of the prosthetic components. The information in the literature about the relative merits of cemented and cementless UKR is contradictory, with some favouring cementless fixation and others favouring cemented fixation. In addition, there is concern about the radiolucency that frequently develops beneath the tibial component with cemented fixation. The exact cause of the occurrence of radiolucency is unknown but it has been hypothesised that it may suggest suboptimal fixation.