Results 1 - 14 of 14
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 4 - 4
1 Apr 2022
Schultz-Swarthfigure C Booth S Biddle M Wilson W Mullen M Smith C
Full Access

Introduction

Lower limb open fractures are severe injuries, with a joint orthoplastic approach for management recommended by BOAST. An initial audit highlighted a discrepancy in time to definitive wound coverage between the Queen Elizabeth University Hospital (QEUH), which at the time was not an orthoplastic centre, and the Glasgow Royal Infirmary (GRI) which was. Our aim was to perform a secondary audit to identify if the introduction of an orthoplastic service at the QEUH led to a reduction in time to definitive wound coverage.

Materials and Methods

Forty-six patients with open lower limb fractures treated at the QEUH in 2019 following introduction of the orthoplastic service were identified. Management including time to antibiotics and wound coverage, and rates of complication were compared with previous audit data.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 133 - 133
1 Nov 2021
Mullen M Bahney CS Huard J Ehrhart N
Full Access

Introduction and Objective

Exosomal miRNA have been shown to regulate many myogenic and osteogenic pathways involved in injury repair and healing. It is also known that rehabilitation and exercise can improve muscle mass and bone growth. The mechanisms by which this occurs in vivo are well studied, but the impact exosomes and their associated miRNA cargo have is unclear. With this knowledge and question in mind, we hypothesized that C2C12 myoblasts subjected to in vitro mechanical stimulus (“exercise”) would exhibit improved exosome production and differentially expressed miRNA cargo when compared to their static (“unexercised”) counterparts.

Materials and Methods

C2C12 myoblasts were cultured using the FlexCell FX-5000TT bioreactor. Two exercise regimens were programmed: 1) low intensity regimen (LIR) (0–15% strain at 0.5 Hz for 24 hours) 2) high intensity interval regimen (HIIR) (12–22% strain at 1 Hz for 10 minutes followed by 50 minutes of rest repeated for 24 hours). Unexercised (static) cells were cultured in parallel. Exosomes were isolated using the Invitrogen Total Exosome Isolation Reagent. The Pierce BCA Protein Assay, System Bioscience's ExoELISA-ULTRA CD81 Kit and, SBI's ExoFlow-ONE EV labeling kit were used to confirm and quantify exosome number and protein concentration. The SBI Exo-NGS service was used to perform miRNA sequencing on isolated exosomes.


Bone & Joint Research
Vol. 8, Issue 1 | Pages 11 - 18
1 Jan 2019
McLean M McCall K Smith IDM Blyth M Kitson SM Crowe LAN Leach WJ Rooney BP Spencer SJ Mullen M Campton JL McInnes IB Akbar M Millar NL

Objectives

Tranexamic acid (TXA) is an anti-fibrinolytic medication commonly used to reduce perioperative bleeding. Increasingly, topical administration as an intra-articular injection or perioperative wash is being administered during surgery. Adult soft tissues have a poor regenerative capacity and therefore damage to these tissues can be harmful to the patient. This study investigated the effects of TXA on human periarticular tissues and primary cell cultures using clinically relevant concentrations.

Methods

Tendon, synovium, and cartilage obtained from routine orthopaedic surgeries were used for ex vivo and in vitro studies using various concentrations of TXA. The in vitro effect of TXA on primary cultured tenocytes, fibroblast-like synoviocytes, and chondrocytes was investigated using 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) cell viability assays, fluorescent microscopy, and multi-protein apoptotic arrays for cell death.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 54 - 54
1 Jan 2016
Talbot S Bartlett J Zordan R Dimitriou P Mullen M Radic R
Full Access

Purpose

Femoral component malrotation is a common cause for persisting symptoms and revision following total knee arthroplasty (TKA). There is ongoing debate about the most appropriate use of femoral landmarks to determine rotation. The Sulcus Line (SL, See Figure 1) is a three-dimensional curve produced from multiple points along the trochlear groove. Whiteside's Line, also known as the anteroposterior axis (APA), is derived from single anterior and posterior points. The purposes of the three studies presented are to i) assess the SL in a large clinical series, ii) demonstrate the effect of parallax error on rotational landmarks, and iii) assess the accuracy of a device which transfers a geometrically corrected SL onto the distal cut surface of the femur.

Methods

The first study assessed the SL using a large, single surgeon series of consecutive patients (n=200) undergoing primary TKA. The postoperative CT scans of patients were examined to determine the final rotational alignment of the femoral component. In the second study measurements were taken in a series of 3DCT reconstructions of osteoarthritic knees (n=44) comparing the rotational landmarks measured along either the mechanical axis or the coronal axis of the trochlear groove. The third study assessed the accuracy of a novel trochlear alignment guide (TAG) using cadavers (n=10)


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 34 - 34
1 Aug 2013
Bell S Mohammed F Mullen M Mahendra A
Full Access

Primary bone tumours of the clavicle are rare. Currently the existing literature is limited to a single case series and case reports or cases. Information regarding the patient's demographics and tumour types is therefore limited.

The aim of this study was to investigate the and also suggest a management protocol for suspected primary bone tumours of the clavicle. We retrospectively reviewed the Scottish Bone Tumour Register from January 1971 to January 2012 and included all primary bone tumours of the clavicle.

We identified only sixteen primary bone tumours over forty one year's highlighting the rarity of these tumours. There were ten benign and six malignant tumours with a mean age of 32 years (Range 4 to 66). The average presentation to orthopaedics after onset of symptoms was two months with five patients presenting following a pathological fracture. Malignant tumour types identified were consistent with previous literature with two cases of Ewing's sarcoma and osteosarcoma and a single case of osteosarcoma post radiotherapy and a single case of chondrosarcoma. Benign tumours were treated effectively with intralesional procedures. Malignant tumours were treated with wide local excision and subtotal or total clavicle excision.

We suggest an investigatory and treatment protocol for patients with a suspected primary bone tumour of the clavicle. This is the largest series of primary bone tumours of the clavicle in the literature.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 33 - 33
1 Aug 2013
Bell S Mullen M Leach W Rooney B
Full Access

We report the short term follow up of nineteen consecutive PFC sigma unicompartmental knee replacements carried out in our institution with minimum one year follow up. The PFC Sigma medial unicompartmental knee replacement is a fixed bearing, cemented unicompartmenal knee replacement. There are currently no published reports of follow up for the PFC Sigma medial unicompartmental knee replacement.

Nineteen patients (nineteen knees) underwent PFC sigma medial unicompartmental knee arthroplasty. The pre-operative diagnosis was osteoarthritis in eighteen patients and osteonecrosis in one patient. There were ten males and nine females with a mean age of sixty four years. All patients had clinical and radiological review at one year. All operations were carried out by the two senior authors (BPR and BL).

The mean length of admission was 2.7 days (Range 2–5). There have been no infective or thromboembolic complications to date. The mean oxford scores improved from 41 (Range 26–52) pre-operatively to 18 (15–27) at one year follow-up. The mean range of motion improved from 115 degrees of flexion preoperatively to 125 degrees. All radiographs were satisfactory at one year follow up with no evidence of loosening.

We report the promising early results of a new medial unicompartmental knee replacement with at least one year follow up. No early complications or infections were identified in our cohort of patients.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 45 - 45
1 Aug 2013
Mullen M Bell SW Rooney BP Leach WJ
Full Access

The number of revision knee arthroplasties performed is projected to rise dramatically in the coming years. Primary knee arthroplasties are also being performed in younger patients increasing the likelihood of multiple revision procedures. Reconstruction can be challenging with bone stock deficiencies and ligament incompetence. The aim of this study was to present our results of revision total knee arthroplasty using metaphyseal sleeve components to aid reconstruction.

Sixty seven patients underwent revision total knee arthroplasty between September 2005 and November 2010 using metaphyseal sleeves. There were thirty one male and thirty six female patients. The indication for revision was aseptic loosening in thirty nine, sepsis in fifteen, malalignment in eight and instability in five patients. Thirty four patients had tibial sleeves, thirty patients had both tibial and femoral sleeves and three patients had femoral sleeves during revision.

The patients were followed up for a mean of 32 months (Range 12–60) with outcome data collected prospectively. The mean revised oxford knee scores for the patients improved from 15 (Range 2 to 29) preoperatively to 33 (Range 20 to 45) postoperatively. Mean arc of flexion following revision was 87 degrees (Range 55 to 120). Seventy six percent of patients were satisfied or very satisfied with the result of the revision surgery. There have been no radiographic complications specific to the sleeves and no re-operations. There has been one recurrence of infection in a patient revised for sepsis. This has been managed with suppressive antibiotics due to patient co-morbidities.

Metaphyseal sleeves are an effective adjunct in revision knee arthroplasty. We have had good results with their use. To our knowledge no larger series has been presented or published.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIII | Pages 56 - 56
1 Sep 2012
McGlynn J Mullen M Pillai A Fogg Q Kumar CS
Full Access

Introduction

The exact action of the Peroneus Longus muscle on the foot is not fully understood. It is involved in a number of pathological processes like tendonitis, tenosynovitis, chronic rupture and neurological conditions. It is described as having a consistent insertion to the base of the first metatarsal, but there have also been reports of significant variations and additional slips. Our aim was to further clarify the anatomy of the main insertion of the Peroneus Longus tendon and to describe the site and frequency of other variable insertion slips.

Methods and Materials

The course of the distal peroneus longus tendon and its variable insertion was dissected in 12 embalmed, cadaveric specimens. The surface area of the main insertion footprint and angle of insertion was measured using an Immersion Digital Microscribe and 3D mapping software. The site and frequency of the other insertion slips is also presented.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVIII | Pages 33 - 33
1 Jun 2012
McGlynn J Mullen M Pillai A Clayton R Fogg Q Kumar C
Full Access

The exact action of the Peroneus Longus muscle on the foot is not fully understood. It is involved in a number of pathological processes like tendonitis, tenosynovitis, chronic rupture and neurological conditions. It is described as having a consistent insertion to the base of the first metatarsal, but there have also been reports of significant variations and additional slips.

Our aim was to further clarify the anatomy of the main insertion of the Peroneus Longus tendon and to describe the site and frequency of other variable insertion slips.

The course of the distal peroneus longus tendon and its variable insertion was dissected in 20 embalmed, cadaveric specimens. The surface area of the main insertion footprint was measured using an Immersion Digital Microscibe and 3D mapping software. The site and frequency of the other variable insertion slips is presented.

There was a consistent, main insertion to the infero-lateral aspect of the first metatarsal in all specimens. The surface area of this insertion was found to be proportional to the length of the foot. The insertion in males was found to be significantly larger than females. The most frequent additional slip was to the medial cuneiform. Other less frequent insertion slips were present to the lesser metatarsals.

The main footprint of the Peroneus Longus tendon is on the first metatarsal. There appears to an additional slip to the medial cuneiform frequently. Although we are unsure about the significance of these additional slips, we hope it will lead to a better understanding of the mechanism of action of this muscle and its role both in the normal and pathological foot.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXII | Pages 41 - 41
1 May 2012
Pillai A Mullen M Fogg Q Kumar S
Full Access

Background

Talar neck fractures occur infrequently and are associated with high complication rates. Anatomical restoration of articular congruity is important. Adequate exposure and stable internal fixation of these fractures are challenging.

Aims

We investigate the use of an anterior extensile approach for exposure of these fractures and their fixation by screws introduced through the talo-navicular articulation. We also compare the quality and quantity of exposure of the talar neck obtained by this approach with the commonly described combined medial/lateral approaches.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XI | Pages 7 - 7
1 Apr 2012
Mullen M Pillai A Fogg Q Kumar CS
Full Access

The extended lateral approach offers a safe surgical approach in the fixation of calcaneal fractures. Lateral plating of the calcaneum could put structures on the medial side at risk. The aim was to identify structures at risk on the medial side of the calcaneum from wires, drills or screws passed from lateral to medial.

Ten embalmed cadaveric feet were dissected. A standard extended lateral approach was performed. The DePuy perimeter plate was first applied and 2mm K-wires were drilled through each of the holes. The medial side was now examined to determine the structures at risk through each hole. The process was repeated with the Stryker plate. The calcaneum was divided into 6 zones, by two vertical lines, from the margins of the posterior facet and a transverse line along the axis of the bone through the highest point of the peroneal tubercle.

The DePuy and the Stryker plates have 12 screw positions, 5 of which are common. With both systems, screw positions in zone 1 risk injury to the medial plantar nerve and zone 3 the lateral plantar nerve. A screw through zone 2 compromises the medial plantar in both. Screws through zone 4 risk the lateral plantar nerve with the DePuy plate. Screws through zone 5 of the DePuy plate risk the medial calcaneal nerve. Zone 5 of the Stryker plate and Zone 6 of both are safe.

There is significant risk to medial structures from laterally placed wires, drills or screws. Subtalar screws have the highest risk and have to be carefully measured and placed. The Stryker plating system is relatively safer than the DePuy perimeter plate with three safe zones out of six.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XI | Pages 6 - 6
1 Apr 2012
Mullen M Pillai A Fogg Q Kumar CS
Full Access

Talar neck fractures are associated with high complication rates with significant associated morbidity. Adequate exposure and stable internal fixation remains challenging. We investigated the anterior extensile approach for exposure of these fractures and their fixation by screws introduced through the talo-navicular articulation. We also compared the quality and quantity of exposure of the talar neck obtained by this approach, with the classically described medial/lateral approaches.

An anterior approach to the talus between the tibialis anterior and the extensor hallucis tendons protecting both the superficial and deep peroneal nerves was performed on 5 fresh frozen cadaveric ankles . The surface area of talar neck accessible was measured using an Immersion Digital Microscribe and analysed with Rhinoceros 3D graphics package. Standard antero-medial and antero –lateral approaches were also carried out on the same ankles, and similar measurements taken. Seven talar neck fractures underwent operative fixation using the anterior approach with parallel cannulated screws inserted through the talo-navicular joint.

3D mapping demonstrated that the talar surface area visible by the anterior approach (mean 1200sqmm) is consistently superior to that visible by either the medial or lateral approaches in isolation or in combination. Medial malleolar osteotomy does not offer any additional visualisation of the talar neck. 3D reconstruction of the area visualised by the three approaches confirms that the anterior approach provides superior access to the entirety of the talar neck. 5 male and 2 female patients were reviewed. All had anatomical articular restoration, and no wound problems. None developed non union or AVN.

The anterior extensile approach offers superior visualisation of the talar neck in comparison to other approaches for anatomical articular restoration. We argue that this approach is safe, adequate and causes less vascular disruption.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 483 - 483
1 Nov 2011
Clayton R Mullen M Baird E Patterson P Fogg Q Kumar S
Full Access

Introduction: Tarsometatarsal joint (TMTJ) arthrodesis is traditionally performed through a dorsal approach and is associated with higher incidence of cutaneous nerve damage, prominent metalware and high non-union rates. It is postulated that applying fixation to the plantar (tension) side, rather than the dorsal (compression) side would create a more stable construct with higher union rates. A suitable surgical approach has not previously been described. The aim of this study is to define a plantar surgical approach to the TMTJ’s.

Methods: We dissected 10 cadaveric feet, identifying nerves, vessels, muscles and their innervation on the plantar aspect of the 1st and 2nd TMTJ’s.

Results: We found that in all specimens a plane of dissection could be created between the two terminal divisions of the medial plantar nerve between flexor digitorum brevis and abductor hallucis. Although exposure of the 1st TMTJ was relatively easy, access to the 2nd TMTJ was difficult due to its location at the apex of the transverse metatarsal arch and the overlying peroneus longus insertion. We found that the peroneus longus tendon had a variable insertion not only at the base of the 1st metatarsal but also at the medial cuneiform and the base of the 2nd metatarsal.

Discussion: This is a new surgical approach, following an internervous dissection plane. The feasibility of making an incision over the convex side of the rocker bottom deformity and the biomechanical advantage of a plantarly applied fixation device may make this an attractive surgical approach.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 402 - 402
1 Jul 2008
Mahendra A Jane MJ Mullen M Sharma H Rana B
Full Access

Limb salvage surgery includes all of the surgical procedures designed to accomplish removal of a malignant tumour and reconstruction of the limb in order to achieve an acceptable oncological, functional, and cosmetic result. The aim of this study was to evaluate the functional outcome following endoprosthetic replcament for primary upper & lower extremity musculoskeletal neolplasms.

Between 1983 and 2004, we found 68 patients from the Scottish Tumor Register having had an endoprosthetic reconstruction for upper and lower-extremity malignant musculoskeletal tumours, of which 32 were alive for performing functional assessment (lower extremity-26, upper extremity-6). The clinical, radiological and oncological outcomes were evaluated. The functional outcome was measured by the Musculoskeletal Tumor Society and Toronto Extremity Salvage Score.

The average follow-up was 59 months (range, 1 to 21 years). There were 19 female and 13 male patients. These were anatomically distributed as around the knee (n=18 cases), hip (n=8) and shoulder (n=4). The most common diagnosis was chondrosarcoma (n=10) and osteosarcoma (n=11). Most of the patients were completely satisfied with their condition, with a decreased walking distance as the only notable restriction. There was no correlation between the functional outcome and the type or site of resection. Complications occurred in ten cases, including two cases of aseptic loosening and one case each of recurrent instability, sciatic nerve palsy and femoral nerve palsy. The median functional score using the Musculoskeletal Tumour Society system was 56% and Toronto Extremity Salvage Score was 72%.

Limb salvage for malignant musculoskeletal tumours continues to pose therapeutic and oncological challenges with considerable functional issues, but the good function and local tumour control in most patients justifies its continued use.