header advert
Results 1 - 20 of 22
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 435 - 441
1 May 2024
Angelomenos V Mohaddes M Kärrholm J Malchau H Shareghi B Itayem R

Aims

Refobacin Bone Cement R and Palacos R + G bone cement were introduced to replace the original cement Refobacin Palacos R in 2005. Both cements were assumed to behave in a biomechanically similar fashion to the original cement. The primary aim of this study was to compare the migration of a polished triple-tapered femoral stem fixed with either Refobacin Bone Cement R or Palacos R + G bone cement. Repeated radiostereometric analysis was used to measure migration of the femoral head centre. The secondary aims were evaluation of cement mantle, stem positioning, and patient-reported outcome measures.

Methods

Overall, 75 patients were included in the study and 71 were available at two years postoperatively. Prior to surgery, they were randomized to one of the three combinations studied: Palacos cement with use of the Optivac mixing system, Refobacin with use of the Optivac system, and Refobacin with use of the Optipac system. Cemented MS30 stems and cemented Exceed acetabular components were used in all hips. Postoperative radiographs were used to assess the quality of the cement mantle according to Barrack et al, and the position and migration of the femoral stem. Harris Hip Score, Oxford Hip Score, Forgotten Joint Score, and University of California, Los Angeles Activity Scale were collected.


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 31 - 37
1 Mar 2024
Bunyoz KI Tsikandylakis G Mortensen K Gromov K Mohaddes M Malchau H Troelsen A

Aims

In metal-on-polyethylene (MoP) total hip arthroplasty (THA), large metal femoral heads have been used to increase stability and reduce the risk of dislocation. The increased size of the femoral head can, however, lead to increased taper corrosion, with the release of metal ions and adverse reactions. The aim of this study was to investigate the relationship between the size of the femoral head and the levels of metal ions in the blood in these patients.

Methods

A total of 96 patients were enrolled at two centres and randomized to undergo MoP THA using either a 32 mm metal head or a femoral head of between 36 mm and 44 mm in size, being the largest possible to fit the thinnest available polyethylene insert. The levels of metal ions and patient-reported outcome measures (Oxford Hip Score, University of California, Los Angeles Activity Scale) were recorded at two and five years postoperatively.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 34 - 34
23 Jun 2023
Bunyoz KI Tsikandylakis G Mortensen K Gromov K Mohaddes M Malchau H Troelsen A
Full Access

In metal-on-polyethylene (MoP) THA large femoral metal heads are designed to increase stability and to reduce dislocation risk. The increased head size could lead to increased taper corrosion with the release of metal ions and adverse reactions. Using blood ion measurements, we aimed to investigate the association between femoral head size and metal-ion release after MoP THA.

96 patients were enrolled at two centers and randomized to receive either a 32-mm metal head or a 36–44 mm metal head (the largest possible fitting the thinnest available polyethylene insert). Blood metal ions and PROMs (OHS, UCLA) were measured at two- and five-year follow-ups.

Both 2- and 5-year median chrome, cobalt, and titanium levels were below taper corrosion indicative ion levels. At 5 years, median chrome, cobalt, and titanium levels were 0.5 μg/L (0.50–0.62), 0.24 μg/L (0.18–0.30), and 1.16 μg/L (1.0–1.68) for the 32-mm group, and 0.5 μg/L (0.5–0.54), 0.23 μg/L (0.17–0.39), and 1.30 μg/L (1–2.05) for the 36–44 mm group, with no difference between groups (p=0.825, p=1.000, p=0.558). At 2 years, 7 (32-mm) versus 4 (36–44-mm) patients had elevated ions. At 5 years, 6 (32-mm) versus 7 (36–44-mm) patients had elevated ions. There was no difference in either OHS (p=0.665) or UCLA (p=0.831) between patients with or without elevated blood metal ions.

5 years after the insertion of MoP THAs, we found no differences in the blood metal ion levels between 32 mm heads and 36–44 mm heads and no corrosion-related revisions. As taper corrosion can debut after 5 years, there is still a need for long-term follow-up studies on the association between head size and corrosion in MoP THA.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 87 - 87
23 Jun 2023
Rolfson O Nåtman J Rogmark C Sundberg M Mohaddes M Kärrholm J W-Dahl A
Full Access

In 1975, Sweden started registering primary knee replacement surgeries based on the personal identity number. Individual-based registrations of primary total hip replacements started in 1992 and for hemiarthroplasties the registration started in 2006. The completeness of these registrations is estimated at 98% during the last 10-year period. The long history and high completeness allow for accurate calculations of population-based prevalence of joint replacement and trends over time.

We used all data on primary joint replacements available in the Swedish Arthroplasty Register. The prevalence was calculated using number of alive patients with 1) at least one joint replacement 2) at least one hip replacement 3) at least one knee replacement at the end of each year from 2010 – 2021. Publicly available population numbers were retrieved from Statistics Sweden. We calculated total prevalence and prevalence per age in years.

By the end of 2021, 3.2% of the Swedish population had at least one hip or knee replacement. This was an increase from 2.5% in 2010. Among 80-year-old, the prevalence was 17.5% for any joint replacement. For both hip and knee replacement and all ages, the prevalence was higher for women. For knee replacement, the 2021 prevalence peaked at the age of 89 (9,4%) while the prevalence continuously increased with age for hip replacements.

A considerable proportion of the Swedish elderly population is living with at least one hip or knee replacement. The prevalence has increased during the last 12-year period for both hips and knees. An increasing prevalence may also affect the incidence of fractures and infections. Knowledge about the prevalence is fundamental for planning future demand for primary and revision hip and knee replacement.


Bone & Joint Open
Vol. 4, Issue 5 | Pages 306 - 314
3 May 2023
Rilby K Mohaddes M Kärrholm J

Aims

Although the Fitmore Hip Stem has been on the market for almost 15 years, it is still not well documented in randomized controlled trials. This study compares the Fitmore stem with the CementLeSs (CLS) in several different clinical and radiological aspects. The hypothesis is that there will be no difference in outcome between stems.

Methods

In total, 44 patients with bilateral hip osteoarthritis were recruited from the outpatient clinic at a single tertiary orthopaedic centre. The patients were operated with bilateral one-stage total hip arthroplasty. The most painful hip was randomized to either Fitmore or CLS femoral component; the second hip was operated with the femoral component not used on the first side. Patients were evaluated at three and six months and at one, two, and five years postoperatively with patient-reported outcome measures, radiostereometric analysis, dual-energy X-ray absorptiometry, and conventional radiography. A total of 39 patients attended the follow-up visit at two years (primary outcome) and 35 patients at five years. The primary outcome was which hip the patient considered to have the best function at two years.


Aims

The aim of this study was to compare the mid-term patient-reported outcome, bone remodelling, and migration of a short stem (Collum Femoris Preserving; CFP) with a conventional uncemented stem (Corail).

Methods

Of 81 patients who were initially enrolled, 71 were available at five years’ follow-up. The outcomes at two years have previously been reported. The primary outcome measure was the clinical result assessed using the Oxford Hip Score (OHS). Secondary outcomes were the migration of the stem, measured using radiostereometric analysis (RSA), change of bone mineral density (BMD) around the stem, the development of radiolucent lines, and additional patient-reported outcome measures (PROMs).


We evaluated an anatomical uncemented stem, SP-CL, (Static Physiologicus – CementLess) designed to facilitate insertion and to avoid stress concentration at solitary contact points in a randomized controlled trial, with use of the Corail stem as control. The SPÅ-Cl stem has been on the market since 2014 but is still not well documented.

79 patients (80 hips) were primarily recruited and 71 patients (72 hips, 36 SP-CL, 36 Corail) attended the last follow up at 2 years. The clinical evaluation included several types of PROMs with Oxford Hip Score (OHS) as primary outcome. In addition, repeated measurements of stem migration, changes in bone mineral density and development of radiolucencies were studied with RSA, DXA and conventional radiography.

At two years the Oxford Hip Score did not differ between the SP-CL and Corail stem (estimated mean difference: −0.70 (95% CI: −4.28 – 2.89). In both groups Oxford hip score had almost doubled at 3 months, continued to increase up to 6 months and was about equal at 2 years (SP-CL; median 46 (17–48), Corail; median 47 (19–48)). At 2 years the SP-CL stems showed a median distal migration of −0.23 (−5.2 – 0.1) and the Corail stems of − 0.11 (−4.4 – 0.4). The SP-CL stems showed slightly more loss of bone mineral density in Gruen region 7 (p = 0.003).

We found no difference in clinical results with use of either of the two stems. Bone mineral density loss tended to be higher with use of the SP-CL stem and the early subsidence tended to be more pronounced, which turned out to be compatible with about the same stem stability reached between 1 and 2 years. As a next step we think that the SP-CL stem should be studied in a multi-center setting, before accepted for general use.


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1206 - 1214
1 Jul 2021
Tsikandylakis G Mortensen KRL Gromov K Mohaddes M Malchau H Troelsen A

Aims

We aimed to investigate if the use of the largest possible cobalt-chromium head articulating with polyethylene acetabular inserts would increase the in vivo wear rate in total hip arthroplasty.

Methods

In a single-blinded randomized controlled trial, 96 patients (43 females), at a median age of 63 years (interquartile range (IQR) 57 to 69), were allocated to receive either the largest possible modular femoral head (36 mm to 44 mm) in the thinnest possible insert or a standard 32 mm head. All patients received a vitamin E-doped cross-linked polyethylene insert and a cobalt-chromium head. The primary outcome was proximal head penetration measured with radiostereometric analysis (RSA) at two years. Secondary outcomes were volumetric wear, periacetabular radiolucencies, and patient-reported outcomes.


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 736 - 743
1 Jun 2020
Svensson K Rolfson O Mohaddes M Malchau H Erichsen Andersson A

Aims

To investigate the experience and emotional impact of prosthetic joint infection (PJI) on orthopaedic surgeons and identify holistic strategies to improve the management of PJI and protect surgeons’ wellbeing.

Methods

In total, 18 prosthetic joint surgeons in Sweden were recruited using a purposive sampling strategy. Content analysis was performed on transcripts of individual in-person interviews conducted between December 2017 and February 2018.


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 198 - 204
1 Feb 2020
Perlbach R Palm L Mohaddes M Ivarsson I Schilcher J

Aims

This single-centre observational study aimed to describe the results of extensive bone impaction grafting of the whole acetabular cavity in combination with an uncemented component in acetabular revisions performed in a standardized manner since 1993.

Methods

Between 1993 and 2013, 370 patients with a median age of 72 years (interquartile range (IQR) 63 to 79 years) underwent acetabular revision surgery. Of these, 229 were more than ten years following surgery and 137 were more than 15 years. All revisions were performed with extensive use of morcellized allograft firmly impacted into the entire acetabular cavity, followed by insertion of an uncemented component with supplementary screw fixation. All types of reoperation were captured using review of radiographs and medical charts, combined with data from the local surgical register and the Swedish Hip Arthroplasty Register.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_11 | Pages 42 - 42
1 Aug 2018
Malchau E Rolfson O Grant P Thanner J Karlsson M Mohaddes M
Full Access

Arthroplasty registries have played a key role in the treatment of patients with various joint diseases and conditions since their conception. Swedish hip and knee arthroplasty registries were initiated in late 1970's. The main aim of registries was to create feedback to surgeons. During the last two decades with introduction of patient reported outcomes, data from registries have been increasingly used to compare caregivers and to improve quality of health care. According to the Swedish Hip Arthroplasty Register (SHAR) Sahlgrenska University Hospital had been underperforming during years 2006–2012. In order to improve the outcomes a systematic data driven approach using local and national registries, based on value based management was undertaken.

Representatives from all categories of healthcare staff and patients were invited to join a newly initiated group. The group was asked to define which measurement that contributed most to improve healthcare. Data from SHAR and local registries were used and seventeen different areas of improvement were identified. Several workgroups were initiated.

Between years 2013 and 2017 there was an increase of 60% in the annual volume of elective THAs. The length of stay decreased from 6.4 days to 1.8 days. Satisfaction with outcome of surgery increased from 76% to 90%. Adverse events decreased from 28% to 10%. The risk of re-operations within 2 years decreased from 2.4% to 1.9%.

Data from a national and a local registry were used to identify and implement changes in a large university hospital. Engaging member of staff and creating a graphical tool for continuous feedback drastically improved the quality of care whilst increasing the availability of hip replacements and reducing costs. This project demonstrates the power of registry data and a patient centered approach in engaging staff and improving healthcare.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_11 | Pages 28 - 28
1 Aug 2018
Kärrholm J Svensson K Mohaddes M Rolfson O
Full Access

The reported success rate after treatment with debridement, antibiotics and implant retention (DAIR) of hip prosthesis infections has been found variable. We evaluated all reoperations performed because of infection and reported to Swedish Hip Arthroplasty Register (SHAR) between 1999 and 2016. The analyses were separated into reoperations performed for the first time and those which had been preceded by at least one previous reoperation performed because of the same reason. The outcome was repeated reoperation performed because of infection.

1,882 were first-time procedures (Group I) and 2,275 had been preceded by at least one reoperation due to infection (Group II). Head and/or liner exchange had been performed in 47% of the cases in group I, and in 22% in Group II. The mean age varied between 70 and 71 years and there was a dominance of males in all groups (52–59%). Compared to all primary THR performed during this period (n=319,813) patients with inflammatory disease, idiopathic femoral head necrosis and sequel after childhood disease were overrepresented for this type of procedure.

Between 1999 and 2016 the number of DAIR procedures increased from 29 to 383 per year corresponding to 21 and 72 % of all reoperations performed due to infection. In first time reoperations the survival was 74.5±3.1% if the head/liner had been exchanged and 46.2±3.2% if only irrigation and synovectomy had been performed. In patients reoperated at least one time previously due to infection the survival rates dropped to 68.6±4.6% and 34.5±2.4%.

Compared to first time reoperation with exchange of femoral and/or liner, synovectomy and irrigation without exchange of any implant part(s) resulted in an almost tripled risk of a second reoperation due to same reason (Hazard Ratio: 2.8, 95% confidence interval: 2.4–3.3). In cases previously reoperated because of infection (Group II) exchange of head/liner and debridement had a 28% increased risk of failure compared to the corresponding first time reoperations (1.28 1.02–1.6). If none of the components were replaced in Group II, the risk ratio for a new failure increased almost 4 times (3.8 3.3–4.4). Presence of a cemented stem increased the risk for further reoperations due to infection (1.14 1.02–1.28), but not presence of a cemented cup (1.06 0.92–1.19). All hazard ratios were adjusted for age, gender, diagnosis and type of fixation.

The comparatively good results observed after exchange of head and liner might indicate that this is necessary to perform a sufficiently radical debridement. This observation could also be biased by a surgeon related factor suggesting that component exchange mainly is performed by surgeons with long experience of revision surgery.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_11 | Pages 15 - 15
1 Aug 2018
Rolfson O Mohaddes M Rogmark C Kärrholm J Malchau H
Full Access

The Swedish Hip Arthroplasty Register started in 1979 and celebrates its 40th anniversary in 2019. The Swedish Hip Arthroplasty Register is not primarily a device register or research database; we strive to provide an overall assessment of the care provided with a multidimensional approach, and to disseminate knowledge on best practices in our network of participating hospitals. Since the inception of the register, there has been a marked change in trends and outcomes.

The completeness of registrations has been 97–99% for primary THA, 93–95% for revisions, and 95–98% for HA over the last 10 years. The register contains 371,125 primary THAs, 55,893 HAs, 83,233 reoperations, and 408,110 PROM responses registered in 352,585 unique patients. All outcome measures have improved over time; primary THA has 0.71% 90-day mortality, 94.3% 10-year implant survival, and 2.2% 2-year reoperation rate. At 1-year follow up, 91% of the patients report a clinically significant pain reduction, 76% report a substantial improvement in health-related quality of life, and 89% are satisfied with the result of the operation.

Moving forward, we are developing enhanced online applications for surgeons, patients and the implant industry to access real-time information. This work involves constructing a shared decision-making tool that helps clinicians assessing the future benefits and risks of THA by offering individualized outcome predictions. Further steps forward include randomized clinical trials and nested studies through the registry's platform. The trends and changes in Swedish arthroplasty practice have largely been promoted and facilitated by the register over the last 40 years.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_11 | Pages 31 - 31
1 Aug 2018
Malchau H Svensson K Mohaddes M Rolfson O Graves S Kärrholm J
Full Access

Deep infection after THA is a devastating complication that implies major suffering for the patients and large costs for society. Reports from multiple national and regional registries show increasing incidence of deep infection. Is this a consequence of improved diagnostics, changed virulence of the causative organism, increased co-morbidity of the patients?

An open database will be setup and hosted by an existing, high quality registry. All possible variables including patient demographic, detailed surgical information, bacteria/fungus characteristics, antibiotic treatment, radiographic findings and follow-up for 3 years will be collected. The incoming data will be displayed on a dashboard with continuous analyses and statistics. Any individual surgeon or hospital can report data.

A board with members from the International Hip Society and the International Society of Arthroplasty Registries will supervise the process and facilitate scientific analyses from collected data.


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 880 - 886
1 Jul 2017
Mohaddes M Shareghi B Kärrholm J

Aims

The aim of this study was to compare the incidence of aseptic loosening after the use of a cemented acetabular component and a Trabecular Metal (TM) acetabular component (Zimmer Inc., Warsaw, Indiana) at acetabular revision with bone impaction grafting.

Patients and Methods

A total of 42 patients were included in the study. Patients were randomised to receive an all- polyethylene cemented acetabular component (n = 19) or a TM component (n = 23). Radiostereometric analysis and conventional radiographic examinations were performed regularly up to two years post-operatively or until further revision.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 38 - 38
1 Jun 2017
Cnudde P Nemes S Mohaddes M Timperley A Garellick G Burström K Rolfson O
Full Access

The risk of dying following total hip replacement (THR) is low and has declined over the last decades. The influence of comorbidities and worse physical status on mortality leads to the idea that patient-reported health status may also be a predictor of mortality. Although this has not been demonstrated in THR surgery, some studies in other fields have reported an association. The aim of this study was to investigate the relationship between patient-reported health status before THR and the risk of dying up to 5 years post-operatively.

The Swedish Hip Arthroplasty Register runs a nationwide PROMs program including the EQ-5D questionnaire to routinely monitor patients undergoing THR in Sweden. For these analyses, we used register data on 42,862 patients with hip osteoarthritis operated with THR between 2008 and 2012. Relative survival ratio was calculated by dividing the observed survival in the patient group by age- and gender-adjusted expected survival of the general population. Multivariable modelling proceeded with time-transformed Cox proportional hazards. Pre-operative responses to the five EQ-5D dimensions along with age, gender, education status, year of surgery, and hospital type were used as independent variables.

As a group THR patients had a better survival than the general population. Broken down by the five EQ-5D dimensions we observed differentiated survival patters. For all dimensions, those reporting moderate problems (level 2) had higher mortality than those reporting no problems (level 1) and those reporting extreme problems (level 3) had higher mortality than those reporting level 1 or 2.

Worse health status according to the EQ-5D before THR is associated with higher mortality up to five years after surgery. The complexity of the interactions between different patient-factors associated with outcomes complicates accurate assessments of risks and expected benefits for individual patients. EQ-5D responses may be useful in a multifactorial individualized risk assessment before THR.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 30 - 30
1 Jun 2017
Svensson K Mohaddes M Rolfson O Kärrholm J
Full Access

Infection after total hip arthroplasty (THA) is a devastating complication. With an ageing population and increased demands for THA, prosthetic joint infection (PJI) is expected to become an even greater problem in the future. In late PJI a one- or two-stage revision procedure is most often used. Factors determining the outcomes are not fully understood and there is controversy in the choice between the two methods. The, two-stage method in infected THA is regarded as more resource demanding and is associated with a high distress in the patients.

The aim of this study was to compare the risk for second revision (re-revision) between one- and two-stage revision.

During 1979–2015, 1659 first-time revisions performed due to infection were reported to the Swedish Hip Arthroplasty Register. Two-stage revision was the most common procedure (n=1255). Risk for a re-revision was compared between one- and two-stage revision using Cox-regression analysis adjusted for age, sex, diagnosis and method of fixation. The primary end-point was a re-revision regardless of cause. Aseptic loosening, infection, and dislocation necessitating re-revision were used as secondary outcomes.

There was no difference in risk of re-revision regardless of cause (HR (one-stage/two-stage)=0.9, 95% C.I.=0.7–1.1, p=0.3), re-revision due to aseptic loosening (HR=1.1, 95% C.I.=0.7–1.6, p=0.7) or re-revision due to infection (HR=0.7, 95% C.I.=0.5–1.1, p=0.2). Dislocation necessitating a re-revision was less common in the one-stage group (HR=0.4, 95% C.I.=0.2–0.9, p=0.03).

In this analysis re-revision rates were similar in the two groups. When analysed specifically for infection, risk of re-revision did not differ between one and two stage revision. Our findings confirm recent systematic reviews on the matter.

This observational study supports increased utilisation of the one-stage approach. However prospective randomized studies are needed to validate these findings.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 37 - 37
1 Jun 2017
Malchau E Rolfson O Welander A Grant P Karlsson M Mohaddes M
Full Access

During the last decade primary total hip arthroplasty surgery (THA) has increased with 30% in Sweden. Current law guarantees the patient a right to treatment within 90 days. The public health system has had difficulties meeting the increasing demand. Therefore, in 2012 a systematic review of the patients planned for THA was initiated at Sahlgrenska University Hospital's joint replacement unit. In late 2013 the value-based health care (VBHC) management was introduced in our unit.

In 2012 a systematic approach based on the Fast-Track concept was implemented in the joint replacement unit. In 2013 a workgroup consisting of health care professionals involved in the treatment of THA patients was created to improve chosen outcome parameters.

During 2011–2016 the number of elective THA has increased from 317 to 486. The cost per patient has decreased from 75,000 SEK to 65,000 SEK. Length of stay has decreased from 5.9 days to 2.5 days. Satisfaction with outcome of surgery one year after THA increased from 76% to 88%. The number of adverse events decreased from 29% to 11%. Number of re-operations within 2 years decreased from 2,7% to 1,9%.

Fast-Track and VBHC management was initially received with modest enthusiasm in our unit, and was regarded as means to increase production whilst possibly endanger the well-being of the patients. By using continuous feedback using the data collected it was possible to effectively communicate to patients and caregivers that the patients benefitted from the implementation.

VBHC primary aim is to improve patient outcomes and synergetically improve cost and process measurements. This should be appealing to both caregivers and administrators.

Focusing on improvement of outcomes after THA combined with VBHC management has contributed to improvement in quality of care and availability of treatment whilst decreasing cost per patient.


The Bone & Joint Journal
Vol. 99-B, Issue 4_Supple_B | Pages 27 - 32
1 Apr 2017
Cnudde PHJ Kärrholm J Rolfson O Timperley AJ Mohaddes M

Aims

Compared with primary total hip arthroplasty (THA), revision surgery can be challenging. The cement-in-cement femoral revision technique involves removing a femoral component from a well-fixed femoral cement mantle and cementing a new stem into the original mantle. This technique is widely used and when carried out for the correct indications, is fast, relatively inexpensive and carries a reduced short-term risk for the patient compared with the alternative of removing well-fixed cement. We report the outcomes of this procedure when two commonly used femoral stems are used.

Patients and Methods

We identified 1179 cement-in-cement stem revisions involving an Exeter or a Lubinus stem reported to the Swedish Hip Arthroplasty Register (SHAR) between January 1999 and December 2015. Kaplan-Meier survival analysis was performed.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 38 - 38
1 Jun 2016
Mohaddes M Cnudde P Malchau H Kärrholm J
Full Access

Introduction

Stem revision with retention of the old cement mantle (cement-in-cement revision) in cases with an intact cement/bone interface is an appealing option. There has been an increasing use of this technique. In 2014 this cement-in- cement technique was used in 10% of all stem revisions reported to the Swedish Hip Arthroplasty Register (SHAR). We analysed the outcome of cement-in-cement stem revisions reported to the SHAR during years 2001–2014

Patients/Materials & Methods

Since 2001 1292 cement-in-cement revisions (study group), performed with a short (≤150 mm) Exeter stem (n=973) or a Lubinus stem (n=319) were reported to the SHAR. Stem revisions, using short Exeter and Lubinus stems without the use of the cement-in-cement technique (n=2893) acted as the control group in this analysis. Both groups were comparable regarding primary diagnosis. In the study group there were more females and the mean age (73 years) was 2 year older (p<0.001). The primary outcome was re-revision due to all causes (n=413). Re-revision of the stem due to all causes, infections excluded (n=212) was used as secondary outcome. Survival analysis using Kaplan-Meier was performed.