1 Feb 2021
Cho C Min B Bae K Lee K Kim DH

Aims

Ultrasound (US)-guided injections are widely used in patients with conditions of the shoulder in order to improve their accuracy. However, the clinical efficacy of US-guided injections compared with blind injections remains controversial. The aim of this study was to compare the accuracy and efficacy of US-guided compared with blind corticosteroid injections into the glenohumeral joint in patients with primary frozen shoulder (FS).

Methods

Intra-articular corticosteroid injections were administered to 90 patients primary FS, who were randomly assigned to either an US-guided (n = 45) or a blind technique (n = 45), by a shoulder specialist. Immediately after injection, fluoroscopic images were obtained to assess the accuracy of the injection. The outcome was assessed using a visual analogue scale (VAS) for pain, the American Shoulder and Elbow Surgeons (ASES) score, the subjective shoulder value (SSV) and range of movement (ROM) for all patients at the time of presentation and at three, six, and 12 weeks after injection.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 62 - 62
1 Apr 2018
Lee K Min B Bae K Jung J
Full Access

Purpose

Two-stage revision with the removal of all prosthesis has been considered to be the gold standard for treatment of periprosthetic joint infection. However, removal of well-fixed femoral stem is technically challenging and may cause excessive bone loss. The aim of this study was to compare the results between retention and removal of femoral stem when performing two-stage revision total hip arthroplasty for periprosthetic joint infection.

Materials & Methods

From 2007 to 2014, ninety-four patients with infection after hip arthroplasty were treated by using two-stage exchange protocol with temporary articulating spacers. Among them, 38 patients completed the planned second stage reimplantation. Stem was exchanged in 15 patients (group I) and retained in 23 patients (group II). We retrospectively investigated the clinical and radiographic results after an average 39.9 months follow up


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 39 - 39
1 Jan 2016
Min B Lee K Kim K Kang M
Full Access

Total hip arthroplasty (THA) is frequently performed as a salvage procedure for the acetabular fracture when posttraumatic osteoarthritis, posttraumatic avascular necrosis, or fixation failure with subluxation develop. Special considerations for this situation include previous surgical exposure with dense scar tissue, the type and location of implants, the location and amount of heterotopic ossification, indolent infection, previous sciatic nerve palsy, and the pathoanatomy of existing acetabular defect. These factors can influence the choice of surgical exposure and the reconstructive method. The outcomes of THA after acetabular fracture are generally less favorable than those of the nontraumatic degenerative arthritis. Reason for this high failure is the low mean age and the high activity level of the patient. Other important reasons for failure include the problem of acetabular bone deficiency and compromised bone quality. We evaluated the results of cementless THA in patient who had previous acetabular fracture. We also compared this result with those of patients with posttraumatic avascular necrosis of the femoral head.

Forty-five consecutive cementless THAs were performed for the treatment of post-traumatic osteoarthritis after acetabular fracture between December 1993 and December 2008. Of these patients, 15 patients were died or lost to follow-up monitoring before the end of the minimum one year follow-up period. This left 30 patients (30 hips) as the subjects of our retrospective review. We evaluated the clinical and radiographic results of these patients and compared with the results of THA in patients with post-traumatic AVN of the femoral head which had without acetabular damage.

Two hips required revision of the cup secondary to early migration of the acetabular cup (1 hip) and postoperative deep infection (1 hip). There was no significant difference in clinical and radiographic results between two groups except implanted acetabular component size and required bone graft (p<0.05). The Kaplan-Meier ten-year survival rate, with revision as the end-point, was 90% and 96.7% with loosening of acetabular component as the end-point.

Our series suggested that compared with cemented components, uncemented sockets may improve the results of arthroplasty after previous acetabular fracture. In conclusion, cementless THA following acetabular fracture presents unique challenge to the surgeon, careful preoperative assessment and secure component fixation with proper bone grafting is essential to minimize problems.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 112 - 112
1 Mar 2010
Min B Song K Cho C Bae K Lee K
Full Access

It is still unclear whether it is best, when revision surgery is required for replacement of an acetabular component, to treat femoral focal osteolysis with bone-grafting or instead to leave it untreated because the defect is too small and uncontained; the concern is to prevent bone graft from escaping into the hip joint. We hypothesized that progression of osteolysis can halted if the cause of particulate generation is removed and the femoral component is well osseointegrated. We prospectively followed 21 patients (24 hips) who underwent acetabular revision and curetting of proximal femoral osteolysis. These patients were followed for the minimum 3 years (mean, 4.3 years; range, 3–7.4 years).

At the time of the latest follow-up examination, all hips were judged to be stable and to have well-fixed acetabular cups and femoral stems. No hips had significant progression of the osteolytic defect through the follow-up period and none demonstrated any new osteolytic lesion.

Provided that a femoral component is bone ingrown with osseointegration sufficient to provide long-term stability, that the osteolytic defect is in the proximal aspect of the femur, and that the defect is uncontained, simple curettage is an effective alternative to additional bone-grafting.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 142 - 142
1 Mar 2010
Lee KJ Min B Kang C Bae K Cho C
Full Access

The rate of failure of primary THA in patients with osteonecrosis of the femoral head is higher than that in patients who undergo THA because of other diagnoses. We examined the results of cementless THA performed with second-generation in a consecutive series of young patients with osteonecrosis of the femoral head.

Sixty-five consecutive primary THAs with insertion of a femoral stem with a circumferential proximal porous coating (HG Multilock prosthesis) and a cementless acetabular component (Harris-Galante II) were performed in 52 patients with osteonecrosis of the femoral head. These patients were followed prospectively and evaluated at a minimum of 10 years after surgery. Four patients (4 hips) died and three patients (3 hips) were lost to follow-up monitoring. The remaining 45 patients (58 hips) had a mean of 11.1 years (range, 10 to 13.4 years) of clinical and radiographic follow-up.

One stem (1.7%) was revised because of aseptic loosening. Eighteen cups (31%) were revised because of excessive polyethylene wear and osteolysis. One hip (1.7%) underwent revision of both acetabular and femoral component because of excessive polyethylene wear and osteolysis. The mean Harrsi Hip Score improved from 49 points before surgery to 92.8 points after surgery in patients who did not undergo reoperation. Osteolysis around the acetabular component was present in 22 hips (37.9%). Femoral osteolysis was seen in 9 hips (15.5%), and there was no osteolysis below the lesser trochanter in any hip.

Circumferentially porous-coated second-generation femoral prostheses provide excellent fixation in young patients with osteonecrosis of the femoral head. However, a high rate of polyethylene wear and osteolysis in these high-risk patients remains a challenging problem.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_II | Pages 151 - 151
1 Feb 2004
Min B Kang C
Full Access

Introduction: Total hip arthroplasty remains an effective tool for the treatment of patients with end-stage osteonecrosis with collapse of the femoral head, although there is an increased risk for failure. The aim of this study was to assess the clinical and radiographic outcome of the cementless femoral component with a circumferentially porous coated design.

Materials and Methods: Sixty-four total hip arthroplasties in 53 patients with osteonecrosis of the femoral head were available for evaluation after a 5–10 year follow-up period (average, 7 years). The average age at surgery was 48 years (range, 25–66 years). Osteonecrosis etiology was alcohol induced in 31 hips, idiopathic in 21, steroid related in 5, and femoral neck fracture in 7. A cementless Harris-Galante II cup and Multilock cementless femoral stem with circumferentially porous coating in the proximal part were used in all patients.

Results: Average Harris hip scores improved from 51.6 points to 86.6 points. Thigh pain was noticed in 6 hips (9.4%) at the latest follow up. Most of the thigh pain was related to the diffuse osteolysis with stem instability. At the latest follow up, 58 stems (90.6%) displayed stable bony fixation, one (1.6%) fibrous fixation, and five (7.8%) unstable fixation. Twenty-four hips (37.5%) revealed osteolysis mostly in Zones I and VII. Five hips (7.8%) exhibited distal osteolysis. Five hips (7.8%) exhibited mechanical failure of the stem usually associated with the diffuse osteolysis around the stem. The authors have also observed increased polyethylene line wear (annual wear rate = 0.39 mm / year)

Discussion: The increased polyethylene wear may be due to a weaker polyethylene interlocking mechanism of Harris-Galante II cup, a young active age population of osteonecrosis, inadequate polyethylene liner thickness, and frequent sitting cross legged in a non-western population. The midterm results using the circumferentially porous coated stem showed favorable bony ingrowth. Osteolytic lesions were primary limited to proximal Zones I and VII even with increased polyethylene wear particle formation and increased osteolytic lesions in Harris-Galante II cup designs. This may be due to the excellent circumferential osteointegration into the proximal part of the stem.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 5 | Pages 753 - 757
1 Jul 2003
Min B Han M Woo JI Park H Park SR

Cryopreserved patellar tendon allografts are often recommended for reconstruction of anterior cruciate ligaments (ACLs) because living donor fibroblasts are thought to promote repair. Animal studies, however, indicate that ligaments regenerate from recipient rather than donor cells. If applicable to man, these observations suggest that allograft cell viability is unimportant. We therefore used short tandem repeat analysis with polymerase chain reaction (PCR) amplification to determine the source of cells in nine human ACLs reconstructed with cryopreserved patellar tendon allografts. PCR amplification of donor and recipient DNA obtained before operation and DNA from the graft obtained two to ten months after transplantation revealed the genotype of cells and showed only recipient cells in the graft area. Rather than preserve the viability of donor cells, a technique is required which will facilitate the introduction of recipient cells into patellar tendon allografts.