Vol. 106-B, Issue SUPP_6 | Pages 14 - 14
2 May 2024
Menakaya C Durand-Hill M Carrington R Hart A Donaldson J Miles J Briggs T Skinner J
Full Access

The management of femoral bone loss is challenging during revision hip arthroplasty. In patients with Paprosky grade IIIB and IV defects, obtaining fixation and rotational stability using traditional surgical constructs is difficult. The use of a custom-made internal proximal femoral replacement prostheses has been proposed as a solution in patients, with severe femoral bone stock loss. However, there is a paucity in the literature on their use and long-term outcomes. We report on the clinical and radiological results of our cohort.

We retrospectively reviewed all patients who underwent internal proximal femoral replacement for revision hip arthroplasty between April 1996 and April 2019. All patients had at least 2 years of follow-up time.

160 patients underwent limb salvage at our institution using internal proximal femoral replacement. The mean follow-up was 79.7 months (S.D 41.3). Indications for revision included periprosthetic fractures, aseptic loosening, and deep infection. The mean Oxford hip score increased from 13.8 (0–22) to 31.5 (18–43) (paired t-test, p < 0.001). Kaplan-Meier prosthesis survival analysis with revision as the endpoint was 87% at 5 years. None required revision of the femoral stem. There were four dislocations (5%) and there was failure to eradicate the deep infection in four.

This technique allows instant distal fixation, allowing for early mobilisation. Long-term clinical and radiological outcomes are encouraging and the complication rates are acceptable for this patient group.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 8 - 8
24 Nov 2023
Anibueze C Mudiganty S George D McCulloch R Warren S Miles J
Full Access

Aim

Mega-endoprosthesis over the last two decades have played a significant role in management of non-neoplastic cases for limb salvage for a variety of indications involving bone loss, infection, fracture and failed revision surgery. This is a retrospective case control study comparing outcomes of Mega-Endoprosthesis (MEP) in non-neoplastic cases with periprosthetic joint infections (PJI), with previous history of PJI and aseptic revision. Failure was defined as persistence/recurrence of infection, all cause revision, and antibiotic suppression during the follow up period. Secondary aims were identification of causative organisms, resistance profile and causative factors for revision surgery.

Method

A total of 122 patients undergoing 133 MEPs were identified between January 2012 and December 2020. 60 procedures were categorised as group 1 (infection; 50%), 20 as group 2 (previous history of infection; 16.7%), and 53 controls (no infection; 44.2%). Mean age of the cohort was 70.97 years (37.16–94.17), with a mean follow-up of 44.5 months (0.2–179) including patients lost to follow up.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 41 - 41
7 Aug 2023
Al-Jabri T Bentley G McCulloch R Miles J Carrington R Shearman A Donaldson J Jayadev C
Full Access

Abstract

Background

Autologous chondrocyte implantation is a NICE approved intervention however it involves the morbidity of two operations, a prolonged rehabilitation and substantial healthcare costs. This study describes a novel, one-step, bone marrow (BM) derived mesenchymal stem cell (MSC) transplantation technique for treating knee osteochondral lesions and presents our prospective clinical study investigating the success of this technique in 206 lesions over a 5 year period.

Methodology

The surgical technique involves harvesting BM from patients’ anterior superior iliac spines, centrifugation to isolate MSCs and seeding into a type 1 collagen scaffold (SyngenitTM Biomatrix). Autologous fibrin glue is used to secure the scaffold into the defect. Inclusion criteria included patients aged 15 – 55 years old with symptomatic osteochondral lesions >1cm2. Exclusion criteria included patients with ligament instability, uncorrected alignment, inflammatory arthropathy and a Body Mass Index >35 kg/m2. Outcome measures included the Modified Cincinnati Knee Rating System (MCKRS), complications and reoperations.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 37 - 37
7 Aug 2023
Mudiganty S Jayadev C Carrington R Miles J Donaldson J Mcculloch R
Full Access

Abstract

Introduction

Total knee replacement (TKR) in patients with skeletal dysplasia is technically challenging surgery due to deformity, joint contracture, and associated co-morbidities. The aim of this study is to follow up patients with skeletal dysplasia following a TKR.

Methodology

We retrospectively reviewed 22 patients with skeletal dysplasia who underwent 31 TKRs at our institution between 2006 and 2022. Clinical notes, operative records and radiographic data were reviewed.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 17 - 17
7 Jun 2023
Madanipour S Lemanu D Jayadev C Aston W Donaldson J Miles J Carrington R McCulloch R Skinner J
Full Access

Custom acetabular components have become an established method of treating massive acetabular bone defects in hip arthroplasty. Complication rates, however, remain high and migration of the cup is still reported. Ischial screw fixation (IF) has been demonstrated to improve mechanical stability for non-custom, revision arthroplasty cup fixation. We hypothesise that ischial fixation through the flange of a custom acetabular component aids in anti-rotational stability and prevention of cup migration.

Electronic patient records were used to identify a consecutive series of 49 custom implants in 46 patients from 2016 to 2022 in a unit specializing in complex joint reconstruction. IF was defined as a minimum of one screw inserted into the ischium passing through a hole in a flange on the custom cup.

The mean follow-up time was 30 months. IF was used in 36 cups. There was no IF in 13 cups. No difference was found between groups in age (68.9 vs. 66.3, P = 0.48), BMI (32.3 vs. 28.2, P = 0.11) or number of consecutively implanted cups (3.2 vs. 3.6, P = 0.43). Aseptic loosening with massive bone loss was the primary indication for revision. There existed no difference in Paprosky grade between the groups (P = 0.1). 14.2% of hips underwent revision and 22.4% had at least one dislocation event.

No ischial fixation was associated with a higher risk of cup migration (6/13 vs. 2/36, X2 = 11.5, P = 0.0007). Cup migration was associated with an increased risk for all cause revision (4/8 vs. 3/38, X2 = 9.96, P = 0.0016, but not with dislocation (3/8 vs. 8/41, X2 = 1.2, P = 0.26).

The results suggest that failure to achieve adequate ischial fixation, with screws passing through the flange of the custom component into the ischium, increases the risk of cup migration, which, in turn, is a risk factor for revision.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 37 - 37
1 Jul 2022
McCulloch R Palmer A Donaldson J Kendrick B Warren S Atkins B Alvand A Carrington R Taylor A Miles J
Full Access

Abstract

Aims

The primary aim of this study was to evaluate the outcomes of fungal knee periprosthetic joint infection following knee arthroplasty. The secondary aim was to evaluate risk factors for acquiring a fungal PJI.

Patients and Methods

This was a retrospective analysis of patients presenting with a confirmed fungal PJI of the knee in two tertiary centres. There were a total of 45 cases. Isolated fungal infections along with mixed bacterial and fungal infections were included. Mean follow up was 40 months (range 3–118).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 22 - 22
1 Jun 2016
Davidson J Sabah S Berber R Hothi H Miles J Carrington R Power A Skinner J Hart A
Full Access

Introduction

The Birmingham Hip Resurfacing (Smith & Nephew London, UK) is the most popular hip resurfacing (HR) in the UK. However, it is now subject to two Medical Device Alerts (MDA) from the Medicines and Healthcare products Regulatory Agency (MHRA).

Patients/Materials & Methods

A cross-sectional survey of primary metal-on-metal hip procedures recorded on the National Joint Registry for England, Wales and Northern Ireland (NJR) until 5th November 2013 was performed.

Cost-analysis was based on an algorithm for surveillance of HR at a tertiary referral centre and followed previous MHRA guidance. NIHR NHS Treatment costs were used.

The local protocol encompassed: patient outcome scoring (Oxford hip score), blood metal ion measurement (cobalt, chromium), cross-sectional imaging (MRI) and discussion at an internet-enabled multidisciplinary team meeting (iMDT) in addition to routine hip surveillance.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 19 - 19
1 Jun 2016
Stirling E Gikas P Aston W Miles J Pollock R Carrington R Skinner J Briggs T
Full Access

Introduction

THR is one of the most frequently performed operations nationally. A large number of prostheses are available, and the procedure is therefore associated with variation in practice and outcomes. NICE guidelines aim to standardise best practice, and are informed by separate, independent bodies, such as the NJR and ODEP, which monitor data about the implants used and their performance. This study aims to determine whether clinical practice and component use has changed since the publication of NJR data.

Methods

NJR reports from 2006–2014 were analysed, with record made of the different prostheses used in THR, noting ODEP ratings of components used. Analysis was also performed by component type (i.e. cemented and cementless stems and cups), and combinations of components, according to their frequency of use in a given year. The Kruksal-Wallis test was used for statistical analysis.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 25 - 25
1 Jun 2016
Ferguson D Henckel J Holme T Berber R Matthews W Carrington R Miles J Mitchell P Jagiello J Skinner J Hart A
Full Access

Introduction

Surgical simulation and ‘virtual’ surgical tools are becoming recognised as essential aids for speciality training in Trauma & Orthopaedics, as evidenced by the BOA T&O Simulation Curriculum 20131,2. The current generation of hip arthroplasty simulators, including cadaveric workshops, offers the trainee limited exposure to reproducible real life bony pathology. We developed and implemented a novel training course using pathological dry bone models generated from real patient cases to support senior orthopaedic trainees and new consultants in developing knowledge and hands on skills in complex total hip arthroplasty.

Patient/Materials & Methods

A two-day programme for 20 delegates was held at a specialist centre for hip arthroplasty. Three complex femoral and three complex acetabular cases were identified from patients seen at our centre. 3D models were printed from CT scans and dry bone models produced (using a mold-casting process), enabling each delegate to have a copy of each case at a cost of around £30 per case per delegate (Figure 1). The faculty was led by 4 senior Consultant revision hip surgeons. A computerised digitising arm was used to measure cup positioning and femoral stem version giving candidates immediate objective feedback (Figure 2). Candidate experience and satisfaction with the course and models was evaluated with a standardised post-course questionnaire.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_12 | Pages 27 - 27
1 Nov 2015
Berber R Khoo M Carrington R Miles J Skinner J Hart A
Full Access

Introduction

Uncertainties in the management of patients with MOM hip implants continue to be a problem for all surgeons. Guidelines vary and do not fully define or quantify thresholds. We aimed to assess the differences in decision-making amongst an international community of six specialist orthopaedic institutions.

Methods

Five international tertiary referral orthopaedic units (one UK, two USA, and two European) were invited to participate. Each unit organised an MDT panel consisting of 2 or more hip surgeons and a musculoskeletal radiologist. All units discussed the same 10 patients. A full clinical dataset was provided including blood test and all imaging. Differences in the interpretation of findings, management decision and rationale for decisions were compared between institutions.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 427 - 427
1 Dec 2013
Mighell M Miles J Santoni B Anijar L James C
Full Access

Purpose:

Tuberosity healing in hemiarthroplasty for proximal humerus fractures remains problematic. Improved implant design and better techniques for tuberosity fixation have not been met with improved clinical results. The etiology for tuberosity failure is multifactorial; however thermal injury to host bone is a known effect of using polymethylmethacrylate for implant fixation. We hypothesized that the effect of thermal injury at the tuberosity shaft junction could be diminished by utilizing an impaction grafting technique for hemiarthroplasty stems.

Methods:

Five matched pairs of cadaveric humeri were skeletonized and hemiarthroplasty stems were implanted in the proximal humeri in two groups. The first group had full cementation utilized from the surgical neck to 2 cm distal to the stem (cement group) and the second group had distal cementation with autologous cancellous bone graft impacted in the proximal 2.5 cm of the stem (impaction grafting group). Thermocouples were used to measure the inner cortical temperature at the tip of the stem, surgical neck, and at the level of the cement-graft interface for both treatment groups (see Fig. 1). Experiments were initiated with the humeri fully submerged in 0.9% sodium chloride and all three thermocouples registering a temperature of 37 ± 1°C. Statistical analyses were performed with a one-sided, paired t-test.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 6 - 6
1 Mar 2013
RAHMAN J MONDA M MCCARTHY I MILES J
Full Access

Total knee replacement in a commonly performed procedure in the United Kingdom with more than 76000 primary procedures performed in 2010. With so many procedures performed there has to be a robust way of assessing the outcome of the procedure. Gait analysis is a valuable tool in objectively assessing the these patients. Inertial movement units (IMU's) are a fairly new development in gait analysis. The aim of our project is to use IMUs to assess the differences in gait profile between a cohort of healthy controls, a group of pre operative knee replacement patients, a group of 8 week post operative patients and finally a group of post operative knee replacement patients at 1 year. We studied a total of 47 patients. We also had data from a previous study done on healthy controls using the same measurement tool. We measured three parameters: peak swing phase flexion, peak stance phase flexion and stride duration. Our findings indicate that pre-operative patients have a significantly reduced peak flexion in swing and stance with increased stride duration. This shows no improvement at the 8 week mark. At the 1 year mark peak flexion in swing returns to pre operative levels but flexion in stance and stride duration are still poor. These findings may not have been identified without gait analysis. Gait analysis using intertial movement units will add much information to radiographs and clinical examination. This information can also be used to tailor individual patients rehabilitation.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 44 - 44
1 Mar 2013
Mohidin B Gikas P Kerns J Birch H Miles J Briggs T Goodship A
Full Access

Osteoarthritis is associated with changes to the matrix composition of subchondral bone. Raman spectroscopy has the potential to detect in vivo the molecular changes in osteoarthritic subchondral bone. The objectives were to determine the levels of mineralisation, carbonate accumulation and bone remodelling in osteoarthritic subchondral bone, which we defined as within 3mm of articular cartilage. This was compared to the proximal-compartment (10mm distal to articular cartilage) and the head-neck junction. Five osteoarthritic (average age: 76 years) and five normal cadaveric femoral heads (average age: 72 years) were scanned using peripheral quantitative computed tomography and then sectioned coronally. Raman spectroscopy was then used to scan the femoral heads. All scans were done in the plane of the longitudinal axis of the diaphysis. Cores were subsequently extracted and sodium dodecyl sulphate polyacrylamide gel electrophoresis performed to determine the levels of homotrimeric collagen. The phosphate-to-amide I ratio, from the Raman spectra, in osteoarthritic subchondral bone was significantly greater than controls (p=0.023). Within osteoarthritic specimens, the phosphate-to-amide I ratio increased proximally. The density in osteoarthritic subchondral bone was 89mg/cm3 higher than controls (p=0.022), and 494mg/cm3 higher than the osteoarthritic proximal-compartment (p<0.001). Moreover, carbonate substitution into the apatite crystals decreased in osteoarthritic specimens. The carbonate-to-amide I ratio was highest in osteoarthritic subchondral bone. Furthermore, the median α1-to-α2-chain ratio in osteoarthritic specimens was 2:1. The changes found in subchondral bone are important in the pathogenesis of osteoarthritis. This study shows that Raman spectroscopy can detect differences between osteoarthritic specimens and controls, further supporting its potential use in diagnosing bone disorders.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 45 - 45
1 Mar 2013
Kerns J Gikas P Buckley K Birch H McCarthy I Miles J Briggs T Parker A Matousek P Goodship A
Full Access

Osteoarthritis (OA) is a common, debilitating joint disease involving degeneration of cartilage and bone. It has been suggested that subtle changes in the molecular structure of subchondral bone may precede cartilaginous changes in the osteoarthritic joint. To explore these changes Raman spectroscopy was employed as a diagnostic tool. Raman spectroscopy measures inelastic scattered laser light produced when photons interact with chemical materials. Resultant changes in wavelength form spectra relative to the chemical composition of the given sample: with bone this includes the mineral and matrix components, unlike conventional X-rays. The aim of our study is to explore the hypothesis: Changes in matrix composition of osteoarthritic subchondral bone can be detected with Raman spectroscopy. pQCT and Raman spectroscopy were employed to determine the bone mineral density (BMD) and bone quality, respectively. Ten medial compartment OA and five control (non-OA) tibial plateaus were interrogated and analysis performed to compare OA to control, and medial to lateral compartments. The subchondral bone of the medial OA compartments had higher BMD (p=0.05) and thickness compared to lateral and control samples. Spectral analysis revealed there is no difference between the medial and lateral compartments within either cohort. However, there is a statistically significant (p=0.02) spectral difference between the OA and control specimens. The detection of bone matrix changes in osteoarthritis using Raman spectroscopy contributes to the understanding of the biochemical signature of subchondral bone across diseased and control tibial plateaus. This technique has potential to shed light on the role of bone in osteoarthritis.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 21 - 21
1 Mar 2013
RAHMAN J KAYANI B GILLOTT E BENTLEY G SKINNER J MILES J CARRINGTON R BRIGGS T
Full Access

The Royal National Orthopaedic Hospital has completed an extensive trial of ACI versus MACI in the treatment of symptomatic osteochondral defects of the knee. A new technique has now been proposed which is quicker and easier to perform. This is the Gel-Type Autologous Chondrocyte Transplantation, CHONDRONTM. At Stanmore CHONDRON has been used for the past 17 months. Our aim was to assess the short term functional outcome of patients who have undergone CHONDRONTM using validated outcome scoring questionnaires. We retrospectively reviewed the notes of 43 patients that had undergone CHONDRONTM over one year ago and scored them using the Modified Cincinnati Score, the Visual Analogue Score and the Benltey Stanmore Functional Rating Score.

RESULTS

The mean pre-operative Modified Cincinnati Score was 39.9, which improved to a mean of 59.8 post-operatively. The mean Visual Analogue Score improved from 6.7 to 5.1 post-operatively. The median Bentley Functional Rating Score was 3 pre-operatively and 2 post-operatively.

CONCLUSIONS

These early results show that 76% of the patients who were treated with CHONDRONTM experienced a reduction in pain and improvement in post-operative function. In the patients in whom the symptoms were worse, the deterioration in score could be partly explained by numerous previous procedures on the same site, presence of early osteoarthritis or the presence of multiple osteochondral lesions. This highlights the importance of careful patient selection in order to gain maximum benefit from the procedure.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 31 - 31
1 Jan 2013
Dhinsa B Gallagher K Dawson-Bowling S Mohan A Miles J Carrington R Skinner J Briggs T
Full Access

Introduction

The aim of this study was to see if the evaluation of the initial postoperative radiograph following primary knee and hip arthroplasty correlated with clinical outcome at five years postoperatively.

Methodology

Using our institution database we identified forty-nine hip replacements and fifty-two knee replacements performed between 2000 and 2006. All the patients underwent postoperative radiographs one day after surgery and clinical evaluation up to at least five years postoperatively. A consultant radiologist evaluated the radiographs for alignment and component position. The hip arthroplasty patients were assessed clinically using the Harris hip score, Oxford hip score, and the Western Ontario and McMaster Universities Osteoarthritis index (WOMAC). The knee arthroplasty patients were assessed using the Knee Society score, Oxford knee score, and the WOMAC score.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 73 - 73
1 Jan 2013
Gillott E Sun SNM Carrington R Skinner J Briggs T Miles J
Full Access

Background

The Enhanced Recovery Programme (ERP) is an evidence based initiative aimed at speeding up patient recovery after major surgery and improving their outcomes. The Royal National Orthopaedic Hospital, Stanmore (RNOH) is a specialist orthopaedic and implemented an ERP for primary knee arthroplasties from October 2010.

Aims

To analyse the initial results of patients participating in our ERP for primary knee arthroplasty to identify what factors predict their Length of Stay (LoS) and establish where changes can be made to improve outcomes further.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 85 - 85
1 Sep 2012
Stammers J Kahane S Malek S Aston W Miles J Pollock R Carrington R Briggs T Skinner J
Full Access

Infection after knee arthroplasty is a devastating complication. Our aim is to present our outcomes of treating infected knee replacements at a tertiary referral centre.

We performed a consecutive, retrospective case series of all revision knee arthroplasty for infection between January 2006 and December 2008. Case notes were reviewed and data collated on the date and institution of primary arthroplasty, procedures undertaken at our institution, microbiology and bone loss post first stage, serological markers (C-reactive protein, ESR) prior to second stage and outcome.

During this three year period we performed 430 knee revision operations. 51 were in the presence of deep chronic infection. 90% were referred from other hospitals. Overall infection was successfully eradicated in 69%.

Nineteen patients underwent repeat two-stage and overall eleven (58%) patients had successful eradication of infection with multiple two-stages. Of these 47% had F3/T3, the highest grading of Anderson Orthopaedic Research Institute bone loss indicating no metaphyseal bone. A further 12% had bicondylar deficiency on the tibia and no femoral metaphyseal bone (F3/T2b).

Multidrug resistance present in 69% and 47% were infected with multiple organisms. All members of the unsuccessful outcome group had at least one multidrug resistant organism compared to 43% in the successful cohort (P=0.0002). Multiple organisms are associated with an unsuccessful outcome (P=0.056).

Serological markers were not significantly different between the successful and unsuccessful outcome groups.

Where the referring hospital had attempted revision and failed, the chance of eradicating infection dropped from 75% to 58% and the rate of above knee amputation was twelve times higher (3% vs. 36%).

Custom constrained, rotating hinge prostheses enable aggressive soft tissue debridement including ligaments. Successful two-stage requires a multidisciplinary approach including tissue viability nurses, microbiologists and plastic surgeons. Where units lack revision expertise this series suggests early referral increases the chance of limb salvage.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 116 - 116
1 Sep 2012
Dawson-Bowling S Berber O Jalgaonkar A Miles J Aston W Pollock R Skinner J Briggs T
Full Access

Bizarre parosteal osteochondromatous proliferation (BPOP), or Nora's lesion, is a rare condition characterised by the formation of surface-based osteocartilaginous lesions typically affecting the hands and feet. 22 cases were identified from the records of a regional bone tumour unit, dating from 1985 to 2009. Of 22 cases, 9 lesions involved the long bones of the hand, 7 the long bones of the feet, 1 case originated from a sesamoid bone of the foot and 5 from long bones (radius, ulna, femur [2] and tibia). Age ranged from 6 to 66 (mean: 31.8) and male to female ratio was 1.8:1. Diagnosis was based on combined radiological and histological features, and initial surgical treatment was excision in 21 cases, and 1 amputation. Follow-up ranged from 12–162 months (mean 32). Recurrence occurred in 6 patients (27%), with mean time to recurrence 49 months (range 10–120). 2 of 8 patients with complete resection margins developed recurrence (25%), versus 4 of 14 with marginal or incomplete resection (28%). Given the potential surgical morbidity inherent in resection, our data suggest that there may be a role for a relatively tissue-conserving approach to the excision of these lesions.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 15 - 15
1 Sep 2012
Holleyman R Gikas P Tyler P Coward P Carrington R Skinner J Briggs T Miles J
Full Access

Background

It is known that excessive varus alignment of the femoral stem in total hip replacement (THR) creates a sub-optimal biomechanical environment which is associated with increased rates of revision surgery and component wear. Little is known regarding the effect of femoral stem alignment on patient functional outcome.

Methods

A retrospective study of patients undergoing primary THR at the RNOH. Alignment of the femoral stem component in-situ was measured subjectively by a consultant musculoskeletal radiologist in both coronal and sagittal planes using post-operative anterior-posterior and lateral pelvic radiographs. Each THR was grouped into valgus, minor-valgus, neutral, minor-varus or varus coronal plane alignment and posterior, minor-posterior, neutral, minor-anterior or anterior sagittal plane alignment. Patient reported functional outcome was assessed by Oxford Hip Score (OHS) and WOMAC questionnaires after a minimum follow-up of 11 months. Maximum range of passive hip flexion, abduction, adduction, external and internal rotation were measured in clinic. A factorial linear regression model was used to analyse data.