Mwelase S Maré P Marais L Thompson D
Full Access

Children with osteogenesis imperfecta (OI) frequently present with coxa vara (CV). Skeletal fragility, severe deformity and limited fixation options make this a challenging condition to correct surgically. Our study aimed to determine the efficacy of the Fassier technique to correct CV and determine the complication rate.

Retrospective, descriptive case series from a tertiary hospital. We retrospectively reviewed records of a cohort of eight children (four females, 12 hips) with OI (6/8 Sillence type III, 2/8 type IV) who had surgical treatment with Fassier technique for CV between 2014 and 2020.

Inclusion Criteria: All patients with CV secondary to OI treated surgically with Fassier technique.

Exclusion Criteria: Patients older than 18 years; Patients with CV treated non-operatively or by surgical technique different to Fassier technique.

Data relating to the following parameters was collected and analyzed: demographic data, pre- and postoperative neck shaft angle (NSA), complications and NSA at final follow-up.

The mean age at operation was 5.8 years (range 2–10). The mean NSA was corrected from 96.8° preoperatively to 137º postoperatively. At a mean follow-up of 38.6 months, the mean NSA was maintained at 133°, and 83% (10/12) of hips had an NSA that remained greater than 120°. There was a 42% (5/12) complication rate: three Fassier–Duval rods failed to expand after distal epiphyseal fixation was lost during growth; one Rush rod migrated through the lateral proximal femur cortex with recurrent coxa vara; and one Rush rod migrated proximally and required rod revision.

The Fassier technique effectively corrected CV in children with moderate and progressively deforming OI. The deformity correction was maintained in the short term. The complication rate was high, but mainly related to the failed expansion of the Fassier–Duval rods.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 38 - 38
7 Nov 2023
Mdingi V Maré P Marais L
Full Access

Paediatric bone and joint infections remain common in low- and middle-income countries (LMICs). We aimed to determine the complication rate and incidence of disseminated infection in paediatric bone and joint infections in an LMIC setting. Secondly, we aimed to elucidate factors associated with complications and disseminated disease.

We retrospectively reviewed our database for children that presented with bone and joint infections between September 2015 and March 2019. Data were extracted to identify factors that were associated with development of complications and disseminated infection.

We analysed 49 children. The median age at presentation was 6 years (range 1 month to 12 years). Locally advanced disease was present in 13 children (27%). The remaining 36 children were evenly divided (18/49 each, 37%) between isolated AHOM and SA, respectively. Disseminated disease was present in 16 children (33%) and was associated with locally advanced disease, an increase in number of surgeries and an increased length of stay. Twenty-six complications were documented in 22 (45%) children. Chronic osteomyelitis developed in 15/49 (31%) cases, growth arrest in 5/49 (10%), and pathological fracture, DVT and septic shock in 2/49 (4%) each. Complicated disease was associated with locally advanced disease, a higher number of surgeries, disseminated disease and an increased length of stay. Sixty five percent of cases cultured Staphylococcus aureus, while 25% (12/49) were culture negative. The median time from admission to surgery was one day, and the median time from onset of symptoms to surgery was seven days.

We found a high complication rate. One third of patients had locally advanced disease, and this was associated with the development of complications and disseminated disease. Further studies are needed to be able to predict which children will have poor outcomes.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_19 | Pages 11 - 11
1 Dec 2014
Maré P Thompson D
Full Access

Background:

Recurrent or late presenting Tibia Vara is a complex clinical problem. In addition to the multiplanar deformity the disorder is often accompanied by obesity. Simple re-alignment osteotomy with acute correction is effective early in the disease. Its use in recurrent or severe deformities is limited by geometric constraints (mechanical axis translation), difficult fixation and the risk of compartment syndrome. Gradual correction with external fixation devices is a well-accepted technique in these cases. It has been shown to obtain accurate correction and provides stable fixation. This allows early weight bearing which facilitate consolidation and rehabilitation. Hexapod fixators are technically less demanding than standard Ilizarov techniques. The TLHex is a relatively new hexapod fixator available in South Africa. Frame pre-assembly allows easier mounting on a limb with complex deformity. The software allows for non-orthogonal mounting, which simplifies frame-mounting assessment. Double telescoping struts allow greater strut excursion and the outside mounting of struts on the ring increases mounting options for fixation elements.

This is the first report on its use in Blount's disease.

Purpose:

Evaluation of the result of gradual correction with the TLHex external fixator in Blount's disease in terms accuracy of correction, union and complications. Illustration of key hardware and software features.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_13 | Pages 23 - 23
1 Sep 2014
Maré P Thompson D Menchero M
Full Access

Introduction

Management of the sequelae of arthritis of the hip joint has changed over time. Total joint replacement has gained popularity due to retained mobility and stability. In the high demand paediatric and adolescent population problems are encountered with longevity of the procedure. Hip arthrodesis is a useful alternative procedure that sacrifices mobility of the joint to achieve pain relief and restores function. Several surgical techniques have been described to achieve hip fusion. We describe a technique that achieves concentric bone surfaces with hip resurfacing reamers. Maximum bone is preserved to maintain leg length. Trans-articular compression is achieved with cannulated screw fixation. Subtrochanteric de-functioning osteotomy completes the procedure to protect the fusion site and control the position of the limb. Our optimal position of fusion was 30 degrees of flexion, neutral to 5 degrees of abduction and neutral to 10 degrees of external rotation.

Methods

Fourteen patients (8 female) treated by hip arthrodesis over a two-year period are reviewed in terms of clinical and radiological outcome in the short term. Their mean age at hip fusion was 11 years (6–18). The etiology included TB (6 cases), staphylococcal infection (2), non-specific arthritis (3), Perthe's (1), chondrolysis (1) and avascular necrosis following trauma (1).