header advert
Results 1 - 11 of 11
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 502 - 511
1 May 2019
Lidder S Epstein DJ Scott G

Aims

Short-stemmed femoral implants have been used for total hip arthroplasty (THA) in young and active patients to conserve bone, provide physiological loading, and reduce the incidence of thigh pain. Only short- to mid-term results have been presented and there have been concerns regarding component malalignment, incorrect sizing, and subsidence. This systematic review reports clinical and radiological outcomes, complications, revision rates, and implant survival in THA using short-stemmed femoral components.

Materials and Methods

A literature review was performed using the EMBASE, Medline, and Cochrane databases. Strict inclusion and exclusion criteria were used to identify studies reporting clinical and radiological follow-up for short-stemmed hip arthroplasties.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 220 - 220
1 Jan 2013
Lidder S Desai A Dean H Sambrook M Skyrme A Armitage A Rajaratnam S
Full Access

Introduction

Osteochondral defects of the knee may occur following patella dislocation or following direct trauma or twisting injuries to the knee in adolescents. Often a diagnostic and therapeutic challenge, if these lesions are left, posttraumatic osteoarthritis may occur. This retrospective single centre study presents the short-term results following operative fixation of osteochondral fragments of the knee using Omnitech ® screws.

Method

All skeletally immature patients presenting with an osteochondral fracture of their femur or patella confirmed on xray and MRI were identified. Arthroscopic evaluation of the osteochondral defect was performed followed by open reduction and internal fixation of the osteochondral fragment using Omnitech ® screws. A standard postoperative rehabilitation protocol was followed. Patients were evaluated at follow-up using a Knee Injury and Osteoarthritis Outcome Score (KOOS).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 153 - 153
1 Jan 2013
Lidder S Masterson S Grechenig S Heidari N Clements H Tesch P Grechenig W
Full Access

Introduction

Posterior malleolar fractures are present in up to 44% of all ankle fractures. Those involving > 25% of the articular surface have a higher rate of posterior ankle instability which may predispose to post traumatic arthritis. The posterolateral approach to the distal tibia allows direct reduction and stabilization of the posterior malleolus and concomitant lateral malleolus fractures. An anatomical study was performed to establish the safe zone of proximal dissection to avoid injury to the peroneal vessels in this uncommon approach.

Methods

26 unpaired adult lower limbs were dissected using the posterolateral approach to the distal tibia as described by Tornetta et al. The peroneal artery was identified coursing through the intraosseous membrane on deep dissestion as the flexor hallucis longus muscle was reflected medially. The level of its bifurcation was also noted over the tibia. Perpendicular measurements were made from the tibial plafond to these variable anatomical locations.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 152 - 152
1 Jan 2013
Lidder S Masterson S Grechenig S Pilsl U Tanzer K Clements H
Full Access

Percutaneous plating of the distal tibia via a limited incision is an accepted technique of osteosynthesis for extra-articular and simple intra-articular distal tibia fractures. In this study we identify structures are risk during this approach.

Method

Thirteen unpaired adult lower limbs were used for this study. Thirteen, 16-hole synthes®LCP anterolateral distal tibial plates were percutaneously inserted according to the manufacturer instructions and confirmed by xray. Dissection was performed around the plate to examine the relation of nerves and soft tissue.

Results

The neurovascular bundle was under the plate in one case. Over the horizontal limb of the plate, typically the superficial peroneal nerve had a variable course over all four screw holes. The anterior tibial artery coursed over hole number 3 and the Extensor hallucis longistendon was positioned over hole 3 or 4. The Anterior tibialis tendon skirted hole 4 in 12 cases. Over the vertical limb of the plate, the neurovascular bundle coursed over holes, 5 to 7, the superficial peroneal nerve over holes 5 to 7.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 171 - 171
1 Sep 2012
Masterson S Lidder S Yoon W Scott G
Full Access

Introduction

There are conflicting reports in the literature regarding the migration of femoral stems in revision hip arthroplasty following the use of impaction allografting with or without cement. In some cemented series distal migration of the prosthesis within the cement mantle has been recorded, as well as migration of the whole cement/prosthesis construct into the graft.

Method and Results

The results of 26 cases of revision hip replacement using femoral impaction allografting in the absence of bone cement are reported. The mean follow up was 8.5 years (range 4 to 17 years). The technique employed a Freeman stem coated proximally with hydroxyapatite.

Three cases required further revision at 2, 4 and 5 years for high subsidence and unacceptable thigh pain. The remaining 23 cases stabilised following a period of initial settlement and overall results have been comparable to other series that have utilised cement. The initial sinkage in this series occurred mainly in the first six postoperative months. These results, from a single surgeon series, demonstrate that the method is highly technique dependent and relies on adequate graft impaction.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 76 - 76
1 Sep 2012
Lidder S Heidari N Grechenig W Clements H Tesch N Weinberg A
Full Access

Introduction

Posterolateral tibial plateau fractures account for 7 % of all proximal tibial fractures. Their fixation often requires posterolateral buttress plating. Approaches for the posterolateral corner are not extensile beyond the perforation of the anterior tibial artery through the interosseous membrane. This study aims to provide accurate data about the inferior limit of dissection by providing measurements of the anterior tibial artery from the lateral joint line as it pierces the interosseous membrane.

Materials and Methods

Forty unpaired adult lower limbs cadavers were used. The posterolateral approach to the proximal tibia was performed as described by Frosch et al. Perpendicular measurements were made from the posterior limit of the articular surface of the lateral tibial plateau and fibula head to the perforation of the anterior tibial artery through the interosseous membrane.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 102 - 102
1 Sep 2012
Heidari N Lidder S Grechenig W Weinberg A Tesch N Gänsslen A
Full Access

Introduction

Application of an external fixator for type B and C pelvic fractures can be life saving. Anteriorly the fixator half pins can be placed in the long and thick corridor of bone in the supra-acetabular region often referred to as the low anterior ex-fix. Pins in this location are favoured as they are more stable biomechanically. The bone tunnel for the low anterior ex-fix can be visualised with an iliac oblique projection intra-operatively. In some cases despite being outside the articular surface it may still be low enough to pass through the capsular attachment of the hip joint on the anterior inferior iliac spine. We aim to provide radiological markers for the most superior fibres of the capsule to help accurate extra-capsular pin placement within the supra-acetabular bone tunnel.

Materials and Methods

Thirteen cadaveric pelves, embalmed with the method of Thiel, were used for this study. An image intensifier was positioned to acquire an iliac oblique outlet view, such that the supra acetabular bone tunnel was visualised. This was achieved by positioning the beam 30 degrees cephalad and 20 degrees medial. Both left and right hemipelves were examined in this way. A standard size metallic disc was included in all images with in the acetabulum to allow for image calibration. The proximal most fibres of the hip joint capsule were marked with a K-wire so that their relation to the bone tunnel could be clearly seen on the images.

Once all images were acquired they were calibrated and analysed using ImageJ Software to estimate the height and maximum width of the bone tunnel as seen on the images and the vertical distance of the superior most fibres of the capsule from the dome of the acetabulum.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXII | Pages 19 - 19
1 Jul 2012
Masterson S Lidder S Scott G
Full Access

An attempt to analyse whether impaction allografting without cement is more or less satisfactory than the technique with the addition of cement is compromised by conflicting reports of where the migration actually occurs. In some cemented series distal migration of the prosthesis within the cement mantle has been recorded as well as migration of the whole cement/prosthesis construct into the graft.

Two prospective consecutive series of revision hip arthroplasties by a single surgeon:- Group 1; Uncemented impaction grafting revision hip replacement in a series of 30 patients (33 hips). Group 2; Cemented impaction grafting revision hip replacement in a series of 30 patients (31 hips). Group demographics were similar. Each case used the same design of hip implant with the only difference in design being a proximal hydroxyapatite coating used on the uncemented implants.

Follow-up ranged from 2 to 17 years for the uncemented group and from 1 to 11 years for the cemented group. A validated hip scoring system was employed at regular follow up incorporating pain and functional assessment.

Migration rates for the uncemented group were 0 to 15 mm for 30 hips; however 3 hips were revised early due to excessive migration. 3 hips sustained early complications (1 fracture, 1 dislocation, 1 varus malposition of stem). Migration rates for the cemented group were 0 to 9 mm for 29 hips, however the remaining 3 hips were revised due to excessive migration (up to 33mm). Although similar results were obtained in terms of success and also pain and function scores, marginal improvement in results did occur with the cemented series overall. Statistical significance was not reached however. More sinkage occurred in the uncemented group overall, the majority occurring in the first 6 post-operative months. Part of the improvement with the cemented series results may be explained by the improved techniques achieved whilst performing the uncemented series.

These results from a single surgeon demonstrate that the method is highly technique dependent and relies on adequate graft impaction. With sufficient graft and an appropriate prosthetic design, cement is not essential to the early success of this method. However, the extent of the initial migration did not accurately predict a successful outcome for the procedure. The absence of cement removes any confusion as to the location of any migration.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 51 - 55
1 Jan 2012
Masterson S Lidder S Scott G

We report the long-term results of revision total hip replacement using femoral impaction allografting with both uncemented and cemented Freeman femoral components. A standard design of component was used in both groups, with additional proximal hydroxyapatite coating in the uncemented group. A total of 33 hips in 30 patients received an uncemented component and 31 hips in 30 patients a cemented component. The mean follow-up was 9.8 years (2 to 17) in the uncemented group and 6.2 years (1 to 11) in the cemented group. Revision procedures (for all causes) were required in four patients (four hips) in the uncemented group and in five patients (five hips) in the cemented group. Harris hip scores improved significantly in both groups and were maintained independently of the extent of any migration of the femoral component within the graft or graft–cement mantle.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 181 - 181
1 Mar 2010
Ranawat V Lidder S Ahrens P
Full Access

A retrospective review was conducted to evaluate the long term results of surgically excised wrist ganglia over a six year period between January 1998 and March 2005.

The study involved patients who had undergone ganglion surgery around the wrist joint who were contacted by telephone and on whom a follow-up questionnaire was performed. The study included 117 patients with a mean follow up period of 4.2 years (range 1.5 – 8.7 years). There were 40 (34%) dorsal and 77 (66%) volar ganglia. The recurrence rate for surgically excised dorsal ganglia was 32.5% and for volar ganglia was 46.8%. Recurrence occurred in 58% of patients who had previously had their ganglion aspirated. The overall risk of developing a moderate to severely tender scar was 19% and an unsightly scar 9%. In those patients with recurrence of their ganglia, this was 33% and 8% respectively. Despite 49 patients experiencing recurrence, 24 were still satisfied with their treatment and 30 patients would still choose surgical treatment again knowing the risk of recurrence

This study questions the effectiveness of surgery in the treatment of wrist ganglia in that recurrence rates are similar to rates seen in studies merely observing or aspirating ganglia. Not only does one have to question the surgical risks that are undertaken but also the demands on healthcare resources.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 63 - 63
1 Mar 2010
Masterson S Lidder S Pollock R Skinner J Cannon S Briggs T Taylor S Blunn G
Full Access

Introduction: The non-invasive growing prosthesis continues to be used successfully for the treatment of limb salvage operations in tumour patients. We report our continued experience in 17 skeletally immature patients with osteosarcoma of the distal femur.

Methods: Patients had a mean age of 10.2 years (range 6 to 15) at the time of surgery. The endoprosthesis was lengthened at appropriate intervals in outpatient clinics without anaesthesia using the principle of electromagnetic induction.

Results: The mean follow-up was 28 months (range 2 to 55). The prostheses were lengthened by a mean of 47.4 mm (range 0.5 to 208) and maintained a mean knee flexion of 110 degrees (range 90 to 120 degrees).

Complications developed in seven patients: two implants failed requiring revision, one peri-prosthetic fracture occurred, one developed a flexion deformity of 25 degrees at the knee joint, which was subsequently overcome and three died of disseminated disease.

Discussion: The medium term results from patients treated with this device have continued to show a promising outcome. Four patients successfully completed desired lengthening, six patients are continuing with ongoing lengthening. The implant avoids multiple surgical procedures, general anaesthesia and assists in maintaining leg-length equality.