header advert
Results 1 - 2 of 2
Results per page:
Applied filters
Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 504 - 504
1 Oct 2010
Hantes M Basdekis G Karidakis G Liantsis A Malizos K Venouziou A
Full Access

Aim: To determine the quantity and the quality of the bone bridge between the bone tunnels, in both the femoral and tibial side, after double-bundle anterior cruciate ligament (ACL) reconstruction.

Material and methods: Twenty-seven patients undergoing primary double-bundle ACL reconstruction with hamstring tendon autograft were included in this prospective study. Computed tomography (CT) was performed in all patients at a mean of 13 months postoperatively. The amount of the bone bridge between the bone tunnels was measured, in both the femoral and tibial side, on an axial plane at three locations:

at the level of the joint line

at the mid-portion of the bone bridge and

at the base of the bone bridge.

In addition, the bone density of the bone bridge was measured in Hounsfield units (HU) in the same locations. Bone density of the anterior tibial cortex lateral femoral condyle, and adjacent cancellous area, and were measured for comparisons.

Results: CT confirmed that the bone bridge was triangular in shape in all cases in both the femoral and tibial side. On the femoral side, at the level of joint line (apex of the bone bridge) the mean thickness of the bone bridge was 1.7 mm, at the mid-portion the mean thickness of the bone bridge was 3.7 mm and at the base of the bone bridge the mean thickness was 7.1 mm. On the tibal side, at the level of joint line (apex of the bone bridge) the mean thickness of the bone bridge was 1.5 mm, at the mid-portion the mean thickness of the bone bridge was 3.2 mm and at the base of the bone bridge the mean thickness was 6.5 mm. Bone density at the mid-portion and at the base of the bone bridge was similar to the cancellous bone for both the femoral and tibial side. However, the bone density of the bone bridge, at the level of the joint line, for the femoral side was 860 HU and this was not statistically significant in comparison to the density of the lateral femoral cortex (960 HU). Similarly, the bone density of the bone bridge, at the level of the joint line, for the tibial side was 885 HU and this was not statistically significant in comparison to the density of the anterior tibial cortex (970 HU).

Conclusions: Our study demonstrated one year after double-bundle ACL reconstruction the thickness of the triangular bone bridge between the bone tunnels is sufficient at the mid-portion and at the base of the triangle but is thin at the level of the joint line. However, the bone bridge at the apex of the triangle is very strong since its density is similar to that of cortical bone. We believe that the “corticalization” of the bone bridge at the level of the joint line on both the femoral and tibial side is important and contributes significantly to avoid communication of the bone tunnels.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 307 - 307
1 May 2009
Dailiana Z Poultsides L Varitimidis S Papatheodorou L Liantsis A Malizos K
Full Access

Flaps constitute an integral part of the treatment of soft tissue and skeletal infections of the extremities, focusing on the coverage and augmentation of the local biology.

In a 6-year period, a total of 33 septic defects of the upper (6) and lower (27) extremities were treated with 4 free and 29 pedicled flaps, after extensive surgical debridement of the septic site. In the lower extremity, treatment included 3 free (2 latissimus dorsi and 1 serratus anterior), and 24 pedicled flaps (5 heads of gastrocnemius, 7 soleus, 1 abductor hallucis, 9 reverse fasciocutaneous, 1 combined medial head of gastrocnemius and soleus and 1 extensor longus hallucis) for 3 cases of soft tissue sepsis and 24 septic defects of the skeleton. In the upper extremity, 1 free vascularised fibular graft (combined with muscle-skin) and 5 pedicled flaps (2 homodigital, 1 heterodigital, 1 cross-finger, 1 periosteal) were used for 3 soft tissue and 3 skeletal septic defects. All but one flaps of the lower extremities were covered with split thickness skin (simultaneously or within 7 days), whereas flaps of the upper extremity included skin in all cases.

Three flaps (2 reverse fasciocutaneous and one soleus) were revised (with latissimus dorsi, serratus anterior and extensor longus hallucis flaps respectively) in a mean period of 4 months due to persistent infection and 4 skin grafts were revised due to superficial infection. In a minimum follow-up period of 9 months (9–60 months) full coverage of the defect and treatment of infection was accomplished in all patients, resulting in a good functional and aesthetic outcome. Except for 2 patients, all were able to walk and use their extremity and returned to previous activities.

The use of flaps in the treatment of septic skeletal or soft tissue defects leads to a functional upper or lower extremity and successfully prevents amputation.