header advert
Results 1 - 8 of 8
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 240 - 248
1 Mar 2024
Kim SE Kwak J Ro DH Lee MC Han H

Aims

The aim of this study was to evaluate whether achieving medial joint opening, as measured by the change in the joint line convergence angle (∆JLCA), is a better predictor of clinical outcomes after high tibial osteotomy (HTO) compared with the mechanical axis deviation, and to find individualized targets for the redistribution of load that reflect bony alignment, joint laxity, and surgical technique.

Methods

This retrospective study analyzed 121 knees in 101 patients. Patient-reported outcome measures (PROMs) were collected preoperatively and one year postoperatively, and were analyzed according to the surgical technique (opening or closing wedge), postoperative mechanical axis deviation (deviations above and below 10% from the target), and achievement of medial joint opening (∆JLCA > 1°). Radiological parameters, including JLCA, mechanical axis deviation, and the difference in JLCA between preoperative standing and supine radiographs (JLCAPD), an indicator of medial soft-tissue laxity, were measured. Cut-off points for parameters related to achieving medial joint opening were calculated from receiver operating characteristic (ROC) curves.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 146 - 146
1 Jan 2016
Lee MC Lee S Park IW Ro DH Kim KB Chung KY Seong SC
Full Access

Purpose

Although the use of stems in revision total knee arthroplasty (RTKA) enhances survival by improving the stability of implant, questions as to the optimal fixation method as well as the vertical extent of the cement, remain unanswered. This study aimed 1) to determine the correlation between the vertical extent of cement and implant loosening; and 2) to determine the minimum cementing extent for a stable implant in revision TKA with a hybrid technique.

Materials and Methods

We retrospectively analyzed 109 stemmed RTKAs with average follow-up of 63 months. In each case, a single varus-valgus constrained implant was used and fixed with a hybrid technique. During surgery, stem was partially covered with cement beyond stem-implant junction. Stability of implant was evaluated according to the modified Knee Society Radiographic Scoring System. Cementing extent was defined as length from implant base to the end of the radiopaque line around the stem. The correlation between the vertical cementing extent and implant stability was analyzed, and the minimal vertical cementing extent for a stable implant was evaluated with a scatter plot.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 112 - 112
1 Jan 2016
Park IW Im SH Kim KB Chung KY Lee S Seong SC Lee MC
Full Access

Over the past twenty years, the Low Contact Stress Rotating Platform (LCS RP) showed good results. Buechel and Pappas invented the Buechel-Pappas Knee (B-P Knee) system that is a modified version of the LCS system with different material (titanium), axial rotation limiting bar and improved conformity. The purpose of this prospective randomized study was to compare the 2-year clinical outcomes between two implants in the same patients who had been operated with bilateral TKAs. We prospectively enrolled 107 patients and 18 patients were lost to follow-up. Therefore, 89 patients (178 knees; mean age, 69.8±6.0years) were included in the study. The range of motion and clinical scores such as Knee Society score (KSS), Hospital for Special Surgery score (HSS) and Western Ontario and McMaster University (WOMAC) scores were measured preoperatively and postoperatively. At each follow-up, patients also complete a Likert scale questionnaire regarding subjective pain, lightness, left-right side preference (naturalness and satisfaction) and subjective instability. There were no significant differences in all preoperative variables between the two groups(P<.05). Mean follow-up period was 29.9±7.2 months. At the 2-year follow-up, mean value of flexion contracture, further flexion and range of motion were not significantly different between both groups. Also, there were no significant differences in the clinical scores and in side to side difference for the feeling of laterality between two groups(P<.05). After minimum 2-year follow-up, we found no differences in early clinical outcomes as well as subjective side to side difference between the LCS RP and B-P Knee system in this study.


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 924 - 932
1 Jul 2015
Lee MC Ha C Elmallah RK Cherian JJ Cho JJ Kim TW Bin S Mont MA

The aim of this study was to assess the effect of injecting genetically engineered chondrocytes expressing transforming growth factor beta 1 (TGF-β1) into the knees of patients with osteoarthritis. We assessed the resultant function, pain and quality of life.

A total of 54 patients (20 men, 34 women) who had a mean age of 58 years (50 to 66) were blinded and randomised (1:1) to receive a single injection of the active treatment or a placebo. We assessed post-treatment function, pain severity, physical function, quality of life and the incidence of treatment-associated adverse events. Patients were followed at four, 12 and 24 weeks after injection.

At final follow-up the treatment group had a significantly greater improvement in the mean International Knee Documentation Committee score than the placebo group (16 points; -18 to 49, vs 8 points; -4 to 37, respectively; p = 0.03). The treatment group also had a significantly improved mean visual analogue score at final follow-up (-25; -85 to 34, vs -11 points; -51 to 25, respectively; p = 0.032). Both cohorts showed an improvement in Western Ontario and McMaster Osteoarthritis Index and Knee Injury and Osteoarthritis Outcome Scores, but these differences were not statistically significant. One patient had an anaphylactic reaction to the preservation medium, but recovered within 24 hours. All other adverse events were localised and resolved without further action.

This technique may result in improved clinical outcomes, with the aim of slowing the degenerative process, leading to improvements in pain and function. However, imaging and direct observational studies are needed to verify cartilage regeneration. Nevertheless, this study provided a sufficient basis to proceed to further clinical testing.

Cite this article: Bone Joint J 2015;97-B:924–32.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 432 - 432
1 Dec 2013
Moon Y Kim K Han S Choi C Lee MC Bin S
Full Access

Purpose:

To investigate treatment patterns and efficacy of postoperative strong opioids in patients who underwent total knee arthroplasty (TKA) in Korea

Methods:

A prospective, non-interventional study of 301 patients who underwent TKA and received strong opioids following patient controlled analgesia (PCA) was conducted by reviewing patient charts and diaries from 19 teaching hospitals. Clinical characteristics, strong opioid treatment patterns, efficacy of strong opioid on a scale of 0–10, and opioid-related adverse events (AEs) were investigated during hospitalization and at first outpatient visit. Safety analysis was conducted on 301 patients, and efficacy analysis was conducted on full analysis set (FAS) which consisted of all the patients who had at least 1 efficacy result among 301 patients.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 566 - 566
1 Sep 2012
Lee MC Lee JK Seong SC Lee S Jang J Lee SM Shim SH
Full Access

Summary

Revision TKA using CCK prosthesis showed comparable outcome to PS prosthesis in clinical and radiological results.

Introduction

In revision total knee arthroplasty (TKA), the goal should be to obtain good motion, function and most importantly stability. The stability depends on remaining soft tissue and implant design. The more the ligaments retain function, the less the implant constraint is needed to achieve stability. With increased constraint, the transfer of joint reaction forces to implant-bone interface may lead to mechanical loosening of the implant. Constrained condylar knee (CCK) prosthesis provides more constraint compared with posterior stabilized (PS) prosthesis. The purpose of this study was to compare the clinical, radiological outcome and survivorship of CCK and PS prosthesis in revision TKA.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 39 - 39
1 Sep 2012
Lee MC Lee SM Seong SC Lee S Jang J Lee JK Shim SH
Full Access

Summary

UC TKA showed similar anteroposterior translation and more femoral external rotation of earlier onset when compared to PS TKA.

Introduction

Recently highly conforming ultracongruent TKA has been reintroduced with improved wear characteristics and lower complications. The purpose of the study was to assess kinematics and clinical outcome of posterior stabilized and ultracongruent rotating-platform mobile bearing TKA.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1081 - 1084
1 Aug 2005
Han I Chang CB Lee S Lee MC Seong SC Kim TK

We sought to determine the degree of correlation between the condition of the patellar articular cartilage and patellofemoral symptoms and function in osteoarthritic patients undergoing total knee arthroplasty. The depth of the osteoarthritic lesion, as graded by the Outerbridge classification and its size and location were assessed to determine the condition of the patellar cartilage in 80 consecutive osteoarthritic knees undergoing total knee arthroplasty. The association between the condition of the cartilage and patellofemoral symptoms and function was investigated by correlation analysis.

The depth and size of the lesion had a significant but weak correlation with anterior knee pain (r = −0.300 and −0.289; p = 0.007 and 0.009, respectively), whereas location had no significant association (p > 0.05). None had a significant association with patellofemoral functional parameters (chair-rising, stair-climbing, and quadriceps power) (p > 0.05).

Our study indicates that patellofemoral symptoms and function are not completely determined by the condition of the cartilage. Caution should be taken when the symptoms and functional limitations are attributed to a lesion in the patellofemoral joint in making a decision regarding patellar resurfacing in total knee arthroplasty.