header advert
Results 1 - 20 of 21
Results per page:
Bone & Joint Research
Vol. 11, Issue 11 | Pages 826 - 834
17 Nov 2022
Kawai T Nishitani K Okuzu Y Goto K Kuroda Y Kuriyama S Nakamura S Matsuda S

Aims

The preventive effects of bisphosphonates on articular cartilage in non-arthritic joints are unclear. This study aimed to investigate the effects of oral bisphosphonates on the rate of joint space narrowing in the non-arthritic hip.

Methods

We retrospectively reviewed standing whole-leg radiographs from patients who underwent knee arthroplasties from 2012 to 2020 at our institute. Patients with previous hip surgery, Kellgren–Lawrence grade ≥ II hip osteoarthritis, hip dysplasia, or rheumatoid arthritis were excluded. The rate of hip joint space narrowing was measured in 398 patients (796 hips), and the effects of the use of bisphosphonates were examined using the multivariate regression model and the propensity score matching (1:2) model.


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 200 - 205
1 Feb 2022
Orita K Goto K Kuroda Y Kawai T Okuzu Y Matsuda S

Aims

The aim of this study was to evaluate the performance of first-generation annealed highly cross-linked polyethylene (HXLPE) in cementless total hip arthroplasty (THA).

Methods

We retrospectively evaluated 29 patients (35 hips) who underwent THA between December 2000 and February 2002. The survival rate was estimated using the Kaplan-Meier method. Hip joint function was evaluated using the Japanese Orthopaedic Association (JOA) score. Two-dimensional polyethylene wear was estimated using Martell’s Hip Analysis Suite. We calculated the wear rates between years 1 and 5, 5 and 10, 10 and 15, and 15 and final follow-up.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 60 - 60
1 Dec 2021
Rai A Khokher Z Kumar KHS Kuroda Y Khanduja V
Full Access

Abstract

Introduction

Recent reports show that spinopelvic mobility influences outcome following total hip arthroplasty. This scoping review investigates the relationship between spinopelvic parameters (SPPs) and symptomatic femoroacetabular impingement (FAI).

Methods

A systematic search of EMBASE, PubMed and Cochrane for literature related to SPPs and FAI was undertaken as per PRISMA guidelines. Clinical outcome studies and prospective/retrospective studies investigating the role of SPPs in symptomatic FAI were included. Review articles, case reports and book chapters were excluded. Information extracted pertained to symptomatic cam deformities, pelvic tilt, acetabular version, biomechanics of dynamic movements and radiological FAI signs.


Bone & Joint Research
Vol. 10, Issue 10 | Pages 629 - 638
20 Oct 2021
Hayashi S Hashimoto S Kuroda Y Nakano N Matsumoto T Ishida K Shibanuma N Kuroda R

Aims

This study aimed to evaluate the accuracy of implant placement with robotic-arm assisted total hip arthroplasty (THA) in patients with developmental dysplasia of the hip (DDH).

Methods

The study analyzed a consecutive series of 69 patients who underwent robotic-arm assisted THA between September 2018 and December 2019. Of these, 30 patients had DDH and were classified according to the Crowe type. Acetabular component alignment and 3D positions were measured using pre- and postoperative CT data. The absolute differences of cup alignment and 3D position were compared between DDH and non-DDH patients. Moreover, these differences were analyzed in relation to the severity of DDH. The discrepancy of leg length and combined offset compared with contralateral hip were measured.


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1604 - 1610
1 Oct 2021
Takaoka Y Goto K Tamura J Okuzu Y Kawai T Kuroda Y Orita K Matsuda S

Aims

We aimed to evaluate the long-term outcome of highly cross-linked polyethylene (HXLPE) cemented acetabular components and assess whether any radiolucent lines (RLLs) which arose were progressive.

Methods

We retrospectively reviewed 170 patients who underwent 187 total hip arthroplasties at two hospitals with a minimum follow-up of ten years. All interventions were performed using the same combination of HXLPE cemented acetabular components with femoral stems made of titanium alloy. Kaplan-Meier survival analysis was performed for the primary endpoint of acetabular component revision surgery for any reason and secondary endpoint of the appearance of RLLs. RLLs that had appeared once were observed over time. We statistically assessed potential relationships between RLLs and a number of factors, including the technique of femoral head autografting and the Japanese Orthopaedic Association score.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 8 - 8
1 Jul 2020
Holleyman R Kuroda Y Saito M Khanduja V Malviya A
Full Access

Background

The purpose of this study was to report functional outcome scores following arthroscopic acetabular chondral procedures using the U.K. Non-Arthroplasty Hip Registry (NAHR).

Methods

Data on adult patients who underwent hip arthroscopy between January 2012 and December 2018 was extracted from the NAHR. Patients who underwent femoral sided chondral procedures were excluded. Patients who underwent osteophyte excision or a concurrent extra-articular procedure were also excluded. Cases were then classified according to the acetabular chondral procedure performed – ‘chondroplasty’, ‘microfracture’ or ‘none’ (no chondral procedure recorded). Outcomes comprised EuroQol-5 Dimensions (EQ-5D) index and the International Hip Outcome Tool 12 (iHOT-12), preoperatively and at 6 and 12 months.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 2 - 2
1 Jul 2020
Holleyman R Kuroda Y Saito M Malviya A Khanduja V
Full Access

Objectives

The aim of this study was to use registry data to report and compare early patient outcomes following arthroscopic repair or debridement of the acetabular labrum.

Methods

Data on adult patients who underwent arthroscopic labral debridement or repair between January 2012 and March 2019 was extracted from the UK Non-Arthroplasty Hip Registry dataset. Patients who underwent microfracture, osteophyte excision or a concurrent extra-articular procedure were excluded. Outcomes comprised EuroQol-5 Dimensions (EQ-5D) index and the International Hip Outcome Tool 12 (iHOT-12), preoperatively and at 6 and 12 months.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 7 - 7
1 Jul 2020
Holleyman R Kuroda Y Saito M Malviya A Khanduja V
Full Access

Background

This study aimed to investigate the effect of body mass index (BMI) on functional outcome following hip preservation surgery using the U.K. Non-Arthroplasty Hip Registry (NAHR).

Methods

Data on adult patients who underwent hip arthroscopy or periacetabular osteotomy (PAO) between January 2012 and December 2018 was extracted from the UK Non-Arthroplasty Hip Registry dataset allowing a minimum of 12 months follow-up. Data is collected via an online clinician and patient portal. Outcomes comprised EuroQol-5 Dimensions (EQ-5D) index and the International Hip Outcome Tool 12 (iHOT-12), preoperatively and at 6 and 12 months


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 10 - 10
1 Jul 2020
Saito M Kuroda Y Khanduja V
Full Access

Background

Slipped capital femoral epiphysis (SCFE) creates a complex deformity of the hip that can result in cam type of femoroacetabular impingement (FAI), which may in turn lead to the early development of osteoarthritis of the hip. The purpose of this study was to evaluate the existing literature reporting on the efficacy of hip arthroscopic treatment of patients with FAI secondary to SCFE.

Methods

A systematic computer search was conducted based on the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines using Embase, PubMed (Medline), and Cochrane Library up to November 2019. Data such as patient demographics, surgical outcomes and complications that described arthroscopic surgery following FAI secondary to SCFE were retrieved from eligible studies. Two authors independently reviewed study inclusion and data extraction with independent verification.


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 822 - 831
1 Jul 2020
Kuroda Y Saito M Çınar EN Norrish A Khanduja V

Aims

This paper aims to review the evidence for patient-related factors associated with less favourable outcomes following hip arthroscopy.

Methods

Literature reporting on preoperative patient-related risk factors and outcomes following hip arthroscopy were systematically identified from a computer-assisted literature search of Pubmed (Medline), Embase, and Cochrane Library using Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines and a scoping review.


Bone & Joint Research
Vol. 8, Issue 10 | Pages 451 - 458
1 Oct 2019
Kuroda Y Tanaka T Miyagawa T Kawai T Goto K Tanaka S Matsuda S Akiyama H

Objectives

Using a simple classification method, we aimed to estimate the collapse rate due to osteonecrosis of the femoral head (ONFH) in order to develop treatment guidelines for joint-preserving surgeries.

Methods

We retrospectively analyzed 505 hips from 310 patients (141 men, 169 women; mean age 45.5 years (sd 14.9; 15 to 86)) diagnosed with ONFH and classified them using the Japanese Investigation Committee (JIC) classification. The JIC system includes four visualized types based on the location and size of osteonecrotic lesions on weightbearing surfaces (types A, B, C1, and C2) and the stage of ONFH. The collapse rate due to ONFH was calculated using Kaplan–Meier survival analysis, with radiological collapse/arthroplasty as endpoints.


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 787 - 792
1 Jul 2019
Goto K Kuroda Y Kawai T Kawanabe K Matsuda S

Aims

In the 1990s, a bioactive bone cement (BABC) containing apatite-wollastonite glass-ceramic (AW-GC) powder and bisphenol-a-glycidyl methacrylate resin was developed at our hospital. In 1996, we used BABC to fix the acetabular component in primary total hip arthroplasty (THA) in 20 patients as part of a clinical trial. The purpose of this study was to investigate the long-term results of primary THA using BABC.

Patients and Methods

A total of 20 patients (three men and 17 women) with a mean age of 57.4 years (40 to 71), a mean body weight of 52.3 kg (39 to 64), and a mean body mass index (BMI) of 23.0 kg/m2 (19.8 to 28.6) were evaluated clinically and radiologically. Survival analyses were undertaken, and wear analyses were carried out using a computer-aided method.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 20 - 20
1 Apr 2018
Kuroda Y Akiyama H Matsuda S
Full Access

Introduction

For many years, minimally invasive joint-preserving regenerative therapy has been desired for the early stages of osteonecrosis of the femoral head (ONFH). In an animal study using adult rabbits, we reported that a single local injection of rhFGF-2-impregnated gelatin hydrogel, which has superior slow-release characteristics, suppresses the progression of femoral head necrosis. The purpose of this study was to evaluate the safety and clinical outcomes of a single local administration of rhFGF-2-impregnated gelatin hydrogel for the precollapse stage of ONFH. Patients and Methods: Ten patients with femoral heads up to precollapse stage 2 underwent a single local administration of 800-µg rhFGF-2-impregnated gelatin hydrogel and were followed up for two years. The eligibility criteria were age between 20 and 80 years and presence of ONFH at precollapse stage 1 or 2 according to the classification system for ONFH developed by the Japanese Investigation Committee of Health and Welfare. Primary outcomes included adverse events and complications. Secondary outcomes included changes in Harris Hip Scores (HHS), visual analog scale pain scores (VAS), the University of California, Los Angeles (UCLA) activity rating scores, radiological changes as determined via radiographs, computed tomography (CT) scans, and magnetic resonance imaging (MRI) of the hip joint. Results: We included five men (five hips) and five women (five hips), with a mean age of 39.8 years (range: 29–53 years) at the time of surgery. Eight patients had bilateral ONFH, three had already undergone THA on the contralateral side. Eight patients were receiving treatment with corticosteroid therapy, and two patients overused alcohol. Stage 1 and 2 disease was present in one and nine patients, respectively. One patient each had type A, type B, and type C1 disease, whereas seven patients had a type C2 lesion. All Adverse events were recovered without problem. The surgery was performed with a minimally invasive technique based core decompression (1 cm of skin incision), and walking was allowed from the day after surgery. Mean clinical scores improved significantly after three year compared with before surgery (before vs. after: VAS for pain, 21.2 vs. 5.3 mm; UCLA activity score 5.5 vs. 6.6; HHS, 81.0 vs. 98.4 points, respectively). There was only one case of femoral head collapse, and it had the greatest necrosis volume fraction and was considered to be in the early collapse stage at the time of operation. The other nine cases did not involve ONFH stage progression, and collapse was prevented. CT images and recent MRI postoperatively confirmed bone regeneration and reduction of the necrotic area. Conclusion: Clinical application of rhFGF-2-impregnated gelatin hydrogel for patients with precollapse stage of ONFH was feasible and safe. Our research is ongoing, further phase II multiple center study has been started in January 2016.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 56 - 56
1 Feb 2017
Kawata T Goto K So K Kuroda Y Okuzu Y Matsuda S
Full Access

Introduction

The long-term wear performance of highly cross-linked polyethylene (HXLPE) in cemented total hip arthroplasty (THA) has rarely been reported. Here we report a prospective randomized comparative analysis of radiographic wear after a minimum follow-up of 10 years in cemented THAs with either HXLPE or conventional polyethylene (CPE), and assess its clinical relevance.

Patients and Methods

From 1999 to 2001, we conducted 94 primary cemented THAs with a 22.225-mm head at our hospital as part of a prospective randomized trial. All surgeries were performed using a direct lateral approach with a trochanteric osteotomy (Dall's approach). The patients were divided into 4 groups. Twenty-six hips in group A were implanted with CPE sockets against zirconia heads and Charnley-type stems. HXLPE sockets (Aeonian, Kyocera Medical Corp) were implanted in all hips in the other 3 groups. Twenty-five hips in group B were implanted with zirconia heads and KC stems (Kyocera Medical Corp), 23 hips in group C with zirconia heads and distal cylindrical stems, and 20 hips in group D with stainless steel heads and C-stem (DePuy Inc). The sockets were highly cross-linked by gamma irradiation at a dose of 35 kGy, heat annealed at 110ºC, and sterilized with 25 kGy of gamma irradiation in nitrogen.

For radiographic evaluation, anteroposterior radiograms were taken for each patient annually, and every two years postoperatively for wear analyses. Two-dimensional head penetration was measured on each postoperative radiogram using a computer-aided technique.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 45 - 45
1 May 2016
So K Kuroda Y Goto K Matsuda S
Full Access

Introduction

Total hip arthroplasty (THA) for a highly dislocated hip can be problematic and technically challenging. Our previous study on cemented THA with subtrochanteric femoral shortening osteotomy revealed a high incidence (20%) of non-union. Therefore, in 2008, we introduced reverse hybrid THA using S-ROM stem for the treatment of a highly dislocated hip. The purpose of this study was to assess the short-term clinical outcomes of this new method.

Patients and methods

Between 2008 and 2014, 13 consecutive reverse hybrid THAs were performed on nine female patients with highly dislocated hips. The average age at the time of operation was 66 years (range, 55–85 years). The acetabular component was fixed in the true acetabulum with bone cement. Transverse osteotomy was performed below the lesser trochanter to shorten the femur and to prevent over-lengthening. The proximal sleeve of the S-ROM stem was then fixed within the proximal fragment, and the distal fin provided rotational stability of the distal fragment. Thus, the two fragments were fixed to each other with the S-ROM stem, and the resected segment was longitudinally cut for grafting at the junction. The postoperative follow-up period was an average of 4 years (range, 1–7 years), and no patients were lost. Preoperative and final Japanese Orthopaedic Association (JOA) hip score, operation time, bleeding amount, intraoperative and postoperative complications, bone healing at the osteotomy site, implant loosening, and revision surgery were retrospectively investigated.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 5 - 5
1 May 2016
Goto K So K Kuroda Y Okuzu Y Matsuda S
Full Access

Background

Composite screws of uncalcined and unsintered hydroxyapatite (HA) particles and poly-l-lactide (PLLA) were developed as completely absorbable bone fixation devices. So far the durability of HA-PLLA composite screws is unclear when used for the fixation of acetabular bone graft in total hip arthroplasty under full-weight conditions. We have used this type of screw for the fixation of acetabular bone graft in cemented or reverse-hybrid total hip arthroplasty since 2003. Hence, we conducted a follow-up study to assess the safety and efficacy of these screws when used for cemented socket fixation.

Methods

During 2003–2009, HA-PLLA composite screws were used for fixation of acetabular bone graft in cemented or reverse-hybrid primary THA in 106 patients (114 cases). All the THAs were performed through direct lateral approaches, and postoperative gait exercise with full weight bearing usually started two days after surgery. One patient died of an unrelated disease and seven patients were lost to follow-up within 5 years. Finally, 98 patients (106 cases) were followed up for over 5 years and were reviewed retrospectively (follow-up rate, 93%). Radiographic loosening of the acetabular component was assessed according to the criteria of Hodgkinson et al., and the radiolucent line around the socket was evaluated in all zones, as described by DeLee and Charnley.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 131 - 131
1 Jan 2016
Kuroda Y Manabu N So K Goto K Akiyama H Matsuda S
Full Access

Introduction

Ultra-high molecular weight polyethylene (UHMWPE) tape, which comprised threads of UHMWPE fibers with the thickness less than 0.5 mm, was developed as a flexible fixation device. We describe new techniques using UHMWPE tape for the reattachment of the osteotomised fragment and the repair of intraoperative calcar fractures in total hip arthroplasty (THA).

Patients & Methods

We reviewed the medical records and radiographs of the studied subjects after approval of this study by the institutional review board committee. Experiment 1: Between October 2011 and May 2012, 60 consecutive primary THAs were performed with the mini-trochanteric approach, which involved reattaching the osteotomised fragment using UHMWPE tape (Nesplon; Alfresa Pharma, Osaka, Japan). [Fig.1] By splitting the anterior one-fourth of the gluteus medius, the minitrochanteric osteotomy, a half-ellipsoid body about 15 mm long, 10 mm wide, and 5 mm deep, is performed using a curved chisel. After implanting of the prosthesis, the osteotomised fragment is reattached by using two 3-mm wide Nesplon tapes. Using 2.4 mm Kirshner wire, two sets of drill holes are created below the trochanteric bed of the femur. Nesplon tapes are passed through each drill hole and penetrated over the trochanteric fragment. Nesplon tape is tied using a double-loop sliding knot in conjunction with a special tightening gun tensioner up to 20 kgf. [Fig.2] The radiographic results were retrospectively analyzed to determine the incidence of nonunion and complications related to trochanteric site. Hip functional results were rated according to the Japanese Orthopedic Association (JOA) hip score. Experiment 2: Between July 2011 and May 2012, 5-mm wide Nesplon tapes were used for restoration of intraoperative femoral fractures in 4 primary THAs. For the repair of intraoperative proximal femoral fractures, 5-mm wide Nesplon tape is tightened with cerclage wiring technique using the gun tensioner up to 30 kgf. [Fig.3] The postoperative radiographic changes were analyzed.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 19 - 19
1 Jan 2016
So K Kuroda Y Goto K Matsuda S
Full Access

Introduction

In order to reduce polyethylene wear and incidence of osteolysis, and improve the long-term durability of total hip arthroplasty (THA), highly cross-linked polyethylene was introduced for clinical use in substitution for conventional polyethylene. We performed 35 cementless THAs between December 2000 and February 2002, and cross-linked polyethylene was used in these surgeries. The purpose of this study is to research linear wear rate of these hips, and to find the risk factor for high wear rate.

Patients and Methods

32 hips (26 patients) among the 35 could be evaluated at more than 10 years postoperatively. One hip required reoperations due to infection at 8 years postoperatively, and two were lost to followup in less than 10 years. There were 2 males and 24 females, and the observation period was 11.4 years in average (range 10?13 years). The age at the time of operation was 49.4 years in average (range 24?67 years), and body mass index was 22.4 in average (15?34). We used AHFIX total hip prostheses (KYOCERA Medical Corporation) for both acetabular and femoral replacement, and 22 mm Zirconia head was used in all cases. The median cup diameter was 46 mm (range 42?50). Osteolysis and loosening of the implant was evaluated on the anteroposterior radiograph of the hip. Using software for wear measurement (Hip Analysis Suite), linear wear rate and cup inclination angle were measured. Correlation between linear wear rate and age, BMI, cup inclination angle, and cup diameter was investigated using correlation coefficient.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 521 - 521
1 Dec 2013
Sasaki H Ishida K Tei K Shibanuma N Matsumoto T Kuroda Y Oka S Matsuzaki T Uefuji A Tateishi H Kuroda R Kurosaka M
Full Access

Introduction

Increased long-term survival of TKA is becoming more important. Several studies have confirmed that optimal positioning and alignment of prosthetic components is crucial for the best long-term results. Therefore, the purpose of the current study was to compare the postoperative alignment and sizing of femoral prosthesis among patients performed by 3 different navigation systems.

Methods

Twenty patients who underwent primary TKA (E. motion; B. Braun Aesculap, Tuttlingen, Germany) using a CT-free navigation system (OrthoPilot v 4.2) by modified gap technique were enrolled in this study. The results of this study group were retrospectively compared with those in a control group of 20 matched-paired posterior stabilized TKAs (Triathlon;Stryker; Mahwah, NJ, USA) which were using another CT-free navigation system (Stryker Navigation System) by measured technique and 20 matched-paired posterior stabilized TKAs (Press-fit Condylar prosthesis; DePuy, Tokyo, Japan) using CT-based navigation system (VectorVision) by measured technique. Several parameters were evaluated for each patient using Athena Knee (Softcube Co, Ltd. Osaka, Japan), 3-D image-matching software. The coronal component angles and sagittal component angles were measured in relation to mechanical axis (MA). In addition, axial femoral component angle was measured in relation to surgical epicondylar axis (SEA) and axial tibial component angle was measured in relation to Akagi line.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 384 - 384
1 Dec 2013
Kuroda Y Ishida K Matsumoto T Sasaki H Oka S Tei K Kawakami Y Matsuzaki T Uefuji A Nagai K Tsumura N Kuroda R Kurosaka M
Full Access

Background:

The axis of the fibula in the sagittal plane are known as a landmark for the extramedullary guide in order to minimize posterior tibial slope measurement error in the conventional total knee arthroplasty (TKA). However, there are few anatomic studies about them. We also wondered if the fibula in the coronal plane could be reliable landmark for the alignment of the tibia. This study was conducted to confirm whether the fibula is reliable landmark in coronal and sagittal plane.

Methods:

We evaluated 60 osteoarthritic knees after TKA using Athena Knee (SoftCube Co, Ltd, Osaka, Japan) 3-D image-matching software. Angle between the axis of the fibula (FA) and the mechanical axis (MA) in the coronal and sagittal plane were measured.