header advert
Results 1 - 14 of 14
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 13 - 13
10 Feb 2023
Giurea A Fraberger G Kolbitsch P Lass R Kubista B Windhager R
Full Access

Ten to twenty percent of patients are dissatisfied with the clinical result after total knee arthroplasty (TKA). Aim of this study was to investigate the impact of personality traits on patient satisfaction and subjective outcome of TKA.

We investigated 80 patients with 86 computer navigated TKAs (Emotion®, B Braun Aesculap) and asked for patient satisfaction. We divided patients into two groups (satisfied or dissatisfied). 12 personality traits were tested by an independent psychologist, using the Freiburg Personality Inventory (FPI-R). Postoperative examination included Knee Society Score (KSS), Western Ontario and McMaster University Osteoarthritis Index (WOMAC) and the Visual Analogue Scale (VAS). Radiologic investigation was done in all patients.

84% of our patients were satisfied, while 16% were not satisfied with clinical outcome. The FPI-R showed statistically significant influence of four personality traits on patient satisfaction: life satisfaction (ρ = 0.006), performance orientation (ρ =0.015), somatic distress (ρ = 0.001), and emotional stability (ρ = 0.002). All clinical scores (VAS, WOMAC, and KSS) showed significant better results in the satisfied patient group. Radiological examination showed optimal alignment of all TKAs. There were no complications requiring revision surgery in both groups.

The results of our study show that personality traits may influence patient satisfaction and clinical outcome after TKA. Thus, patients personality traits may be a useful predictive factor for postoperative satisfaction after TKA.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 35 - 35
1 Dec 2021
Sigmund IK Holinka J Sevelda F Staats K Lass R Kubista B Giurea A Windhager R
Full Access

Aim

Although established serum inflammatory biomarkers, such as serum C-reactive protein (CRP) and serum white blood cell count (WBC), showed low accuracies in the literature, they are still commonly used in diagnosing periprosthetic joint infections (PJI). For a sufficient preoperative diagnosis novel more accurate serum parameters are needed. The aim of our study was to evaluate the performances of the established and novel routinely available serum parameters in diagnosing periprosthetic joint infections when using the proposed European Bone and Joint Infection Society (pEBJIS) criteria.

Method

In this retrospective study, 177 patients with an indicated revision surgery after a total joint replacement were included from 2015 to 2019. The easily accessible and routinely available serum parameters CRP, WBC, the percentage of neutrophils (%N), the neutrophils to lymphocytes ratio (NLR), fibrinogen and the platelet count to mean platelet volume ratio (PC/mPV) were evaluated preoperatively. The performances were examined via receiver operating characteristic (ROC) curve analysis (AUC). The curves were compared using the z-test. Seventy-five cases (42%) showed a PJI based on the pEBJIS-criteria.


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 288 - 296
1 Mar 2019
Sigmund IK Holinka J Sevelda F Staats K Heisinger S Kubista B McNally MA Windhager R

Aims

This study aimed to assess the performance of an automated multiplex polymerase chain reaction (mPCR) technique for rapid diagnosis of native joint septic arthritis

Patients and Methods

Consecutive patients with suspected septic arthritis undergoing aseptic diagnostic joint aspiration were included. The aspirate was used for analysis by mPCR and conventional microbiological analysis. A joint was classed as septic according to modified Newman criteria. Based on receiver operating characteristic (ROC) analysis, the area under the ROC curve (AUC) values of the mPCR and the synovial fluid culture were compared using the z-test. A total of 72 out of 76 consecutive patients (33 women, 39 men; mean age 64 years (22 to 92)) with suspected septic arthritis were included in this study.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 6 - 6
1 Jan 2018
Petis S Kubista B Hartzler R Abdel M Berry D
Full Access

Uncemented component retention with polyethylene (PE) liner and femoral head exchange is commonly used to treat periprosthetic osteolysis. The purpose was to determine long-term implant survivorship, risk factors for aseptic failures, clinical outcomes, and complications following PE liner and head exchange.

We identified 116 hips in 110 patients treated with PE liner and head exchange for osteolysis from 1993 to 2004. The mean age was 58, 64 were women, and mean follow-up was 11 years.

Implant survivorship free from all-cause revisions was 91% at 5-years, 81% at 10-years, and 69% at 15-years. Reasons for re-revision included subsequent conventional PE wear and osteolysis in 7 (6%), aseptic acetabular loosening in 5 (4%), and instability in 5 hips (4%). Mean time to revision for aseptic acetabular loosening was 4 years (range 1 – 7 years). Risk factors for aseptic acetabular loosening included acetabular zones of pre-revision osteolysis, percentage of cup involvement, and size of osteolytic defects. Absolute risk of acetabular loosening was 23% for three zones of osteolysis (Relative Risk (RR) 12, p<0.01), 40% if osteolysis involved more than half the cup circumference (RR 14, p<0.01), and 21% for defects greater than 600 mm2 (RR 11, p<0.01). Harris hip scores improved from 77 to 87 (p<0.01). The most common complication was dislocation (16%).

These data quantify risk of subsequent component loosening when well fixed, uncemented implants are retained during operations for osteolysis, and may inform operative decisions regarding shell retention versus revision.


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 66 - 72
1 Jan 2017
Sigmund IK Holinka J Gamper J Staats K Böhler C Kubista B Windhager R

Aims

The diagnosis of periprosthetic joint infection (PJI) remains demanding due to limitations of all the available diagnostic tests. The synovial fluid marker, α-defensin, is a promising adjunct for the assessment of potential PJI. The purpose of this study was to investigate the qualitative assessment of α-defensin, using Synovasure to detect or exclude periprosthetic infection in total joint arthroplasty.

Patients and Methods

We studied 50 patients (28 women, 22 men, mean age 65 years; 20 to 89) with a clinical indication for revision arthroplasty who met the inclusion criteria of this prospective diagnostic study. The presence of α-defensin was determined using the qualitative Synovasure test and compared with standard diagnostic methods for PJI. Based on modified Musculoskeletal Infection Society (MSIS) criteria, 13 cases were categorised as septic and 36 as aseptic revisions. One test was inconclusive.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_23 | Pages 6 - 6
1 Dec 2016
Sigmund IK Holinka J Gamper J Staats K Böhler C Kubista B Windhager R
Full Access

Aim

Quantitative assessment of alpha-Defensin offers a promising approach for diagnosing a periprosthetic joint infection (PJI) with sensitivities and specificities ranging from 97% to 100% and 95% to 100%, respectively. However, to the best of our knowledge and after due inquiry little information exists concerning qualitative measurements of alpha-Defensin. The aim of this study was to assess the diagnostic accuracy of the alpha-Defensin test, a lateral flow test for the qualitative detection of alpha-Defensin.

Method

In this study, 50 patient with indicated revision surgery met the inclusion criteria due to septic or aseptic loosening. In addition to clinical standard diagnostics of PJI, the alpha-Defensin test* for the assessment of the qualitative alpha-Defensin in the synovial fluid was performed. The results were compared with the sensitivity and specificity of currently available clinical tests, specifically C-reactive protein (CRP), frozen section, definitive histology, bacteriology and sonication.


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 772 - 779
1 Jun 2016
Stihsen C Hipfl C Kubista B Funovics PT Dominkus M Giurea A Windhager R

Aim

Until now, there has been no consensus as to whether stemmed acetabular components are appropriate for use in patients undergoing revision total hip arthroplasty (THA) who have major acetabular defects or pelvic discontinuity. We wished to address this deficiency in the literature.

Patients and Methods

We carried out a retrospective study of 35 patients (six men and 29 women) with a mean age of 68 years (37 to 87), with major acetabular defects who underwent revision THA between 2000 and 2012.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 138 - 138
1 May 2016
Lass R Kubista B Olischar B Frantal S Windhager R Giurea A
Full Access

Material and Methods

In a prospective randomized study of two groups of 65 patients each, we compared the acetabular component position when usingthe imageless navigation system compared to the freehand conventional technique for cementless total hip arthroplasty. The position of the component was determined postoperatively on computed tomographic scans of the pelvis.

Results

There was no significant difference for postoperative mean inclination (p=0.29), but a significant difference for mean postoperativ acetabular component anteversion (p=0.007), for mean deviation of the postoperative anteversion from the target position of 15°(p=0.02) and for the outliers regarding inclination (p=0.02) and anteversion (p<0.05) between the computer-assisted and the freehand-placement group.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 137 - 137
1 May 2016
Lass R Gruebl A Kolb A Stelzeneder D Pilger A Kubista B Giurea A Windhager R
Full Access

Introduction

In a recent study we evaluated the clinical and radiographic long-term results as well as the serum metal concentrations of 105 cementless primary total hip prosthesis, performed between November 1992 and May 1994 with a 28-mm high-carbide-concentration metal-on-metal articulating surfaces. Forty-one patients who had had a total of forty-four arthroplasties were available for follow-up evaluation at a minimum of seventeen years postoperatively.

The median serum cobalt concentration of the patients with their hip replacement as the only source of cobalt was 0.7 µg/L (range 0.4–5.1µg/L), showing no significant difference to the previous study after a minimum of 10 years follow-up. We were investigating the systemic dissemination, which in turn, did not show more severe effects, such as carcinogenicity or renal failure. There are many complex issues associated with the analysis of metal ions, including collecting technique, analysis and reporting of the results. At the AAOS in March 2013, the Hip Society mentioned, that systemic ion levels are just one factor in the evaluation and should not be relied upon solely to determine the need for revision surgery. Furthermore, the correlation between cobalt or chromium serum, urin or synovial fluid levels and adverse local tissue reactions is incompletely understood.

Patients and Methods

In our present study we evaluated the serum, urin as well as the joint aspirate metal concentrations, of cementless total hip arthroplasties with a high-carbon, metal-on-metal bearing (Metasul®) at a mean of eighteen-years follow-up. We performed a correlation analysis to evaluate the relationship between these values and to determine whether elevated serum metal concentrations are associated with elevated and local metal concentrations and with early failure of metal-on-metal articulations.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 86 - 86
1 May 2016
Kasparek M Lazar M Weber M Ringl H Herold C Kasparek M Kubista B Windhager R Toepker M
Full Access

Introduction

Computer Tomography (CT) imaging has been limited to beam hardening artefacts until now. Literature has failed to describe sensitivity and specifity for loosening of endoprothesis in CTs, as metal artefacts have always influenced the diagnostic value of CTs.

In recent years a new technology has been developed, the Dual Energy CT. Dual Energy CT scanners simultaneously scan with two tubes at different energy levels, most commonly 100kVp and 140kVp. Furthermore pictures gained from Dual Energy CTs are post-processed with monoenergetic reconstruction, which increases picture quality while further reducing metal artefacts.

This promising technology has increased the diagnostic value preventing more radiation for the patients, for example in detection of kidney stones or to map lung perfusion. In the musculoskeletal imaging it has not been established yet and further clinical investigations are necessary.

Thus the aim of this study is to describe sensitivity and sensibility for endoprothesis loosening of this novel technology.

Material and Methods

53 prospective patients (31 total hip- and 22 total knee-arthoplasties) who were planned for revision surgery underwent preoperative Dual Energy CT examination. All scans were performed with a second-generation, dual-energy multi-detector CT scanner. And all pictures were post-processed with monoenergetic reconstruction.

Radiologists were blinded for patient´s history. Senior consultants, who are specialized in arthroplasty of the hip and the knee, performed surgery. Intraoperative information was used as gold standard.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 678 - 682
1 May 2013
Holinka J Pilz M Kubista B Presterl E Windhager R

The aim of this study was to evaluate whether coating titanium discs with selenium in the form of sodium selenite decreased bacterial adhesion of Staphylococcus aureus and Staph. epidermidis and impeded osteoblastic cell growth.

In order to evaluate bacterial adhesion, sterile titanium discs were coated with increasing concentrations of selenium and incubated with bacterial solutions of Staph. aureus (ATCC 29213) and Staph. epidermidis (DSM 3269) and stained with Safranin-O. The effect of selenium on osteoblastic cell growth was also observed. The adherence of MG-63 cells on the coated discs was detected by staining with Safranin-O. The proportion of covered area was calculated with imaging software.

The tested Staph. aureus strain showed a significantly reduced attachment on titanium discs with 0.5% (p = 0.011) and 0.2% (p = 0.02) selenium coating. Our test strain from Staph. epidermidis showed a highly significant reduction in bacterial adherence on discs coated with 0.5% (p = 0.0099) and 0.2% (p = 0.002) selenium solution. There was no inhibitory effect of the selenium coating on the osteoblastic cell growth.

Selenium coating is a promising method to reduce bacterial attachment on prosthetic material.

Cite this article: Bone Joint J 2013;95-B:678–82.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XIV | Pages 58 - 58
1 Apr 2012
Funovics P Edelhauser G Kubista B Kotz R Dominkus M
Full Access

Aim

Preoperative serum CRP has been identified as an independent predictor in various malignancies. For osteosarcoma, however, the value of serological markers is unreliable. Aim of this study was to evaluate the prognostic power of preoperative CRP in patients with osteosarcoma.

Method

Out of our prospective database, 87 patients with osteosarcoma (43 female, 44 male with an average age of 20.4 years) have been identified with complete documentation of peri-operative CRP-levels, a minimum two year follow-up and after exclusion of concomitant infection, smoking-history or cardio-vascular disease. Pre-operative CRP before tumour resection was correlated with clinical and pathological factors, overall survival and infection rates in an uni- and multi-variate statistical model with and without landmark analysis.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 604 - 605
1 Oct 2010
Sevelda F Berger W Dominkus M Funovics P Kotz R Kubista B Micksche M
Full Access

Hyperactivation of the epidermal growth factor receptor (EGFR) by gene amplification, mutation as well as overexpression is a hallmark of multiple human carcinomas. However, in recent years data have accumulated that EGFR-mediated signals might also contribute to malignant progression and therapy resistance of human sarcomas. Consequently we have investigated if human osteosarcoma cell lines (n=9) express functional EGFR and its useability as therapeutic target. Osteosarcoma cells expressed distinctly differing level of EGFR reaching in some cases high amounts. However, even low expression levels were sufficient to activate both MAPK and PI3K pathways (determined by phosphorylation of ERK1/2 and S6, respectively) following EGF exposure of serum-starved cells. The EGFR-specific inhibitor gefitinib completely blocked EGF-mediated and attenuated serum-induced downstream signal activation. While gefitinib applied as single agent demonstrated only limited growth inhibiting activity in short term experiments (72h drug exposure), it led to reduced colony formation in long term experiments in the majority of cell lines. Importantly, gefitinb sensitized EGFR-expressing osteosarcoma cell lines against chemotherapy with doxorubicin and methotrexate, while it antagonised cisplatin-induced cell death. Summarizing, our data suggest that EGFR-mediated survival signals protect human osteosarcoma cells against the cytotoxic activity of several antineoplastic drugs. Consequently, combination approaches including EGFR inhibitors in addition to chemotherapy should be evaluated for treatment of high grade osteosarcoma patients.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 536 - 536
1 Oct 2010
Giurea A Holinka J Jenny J Kotz R Kubista B Lass R Miehlke R Pfeiffer M
Full Access

Introduction: Total knee arthroplasty in obese patients remains a challenge to most surgeons. Surgical complication rates as well as perioperative morbidity are higher than total knee arthroplasty in the nonobese. The purpose of this paper is to review our experience with total knee arthroplasty in superobese patients (BMI> 50).

Methods: From 1998–2005, 84 patients underwent 148 knee arthroplasties. Sixty-four patients underwent simultaneous bilateral total knee arthroplasties and 20 patients underwent unilateral knee arthroplasties. They were compared with similar group of nonobese patients who underwent knee arthroplasties during the same time period. All patients received combined regional and general anesthesia.

Results: Mean follow-up was 3.8 years (2–7). Knee society scores improved by 36 points in the superobese (pre-op 47 to 83 post-op) and by 45 points in the non-obese (pre-op 47 to 93 post-op) (p< .05). There was a greater incidence of complications in the superobese group, namely superficial wound infections and deep vein thrombosis. There was late loosening in three tibial components and instability in two patients that required revision in the superobese group. No reoperations in the nonobese group.

Conclusion: Although total knee arthroplasty may be safely performed in the superobese, it may be complicated by infection, loosening, instability, and lower knee scores.