Vol. 94-B, Issue SUPP_XXXIX | Pages 5 - 5
1 Sep 2012
Smith J Railton P Kinniburgh D Faris P David L Marshall D Burkart B Powell J
Full Access

In a cross sectional cohort study three different metal on metal total hip systems were assessed. Two monoblock acetabular designs; the Durom socket (Zimmer, Warsaw, In) and the Birmingham socket (Smith and Nephew, Memphis, TN), and one modular metal on metal total hip system (Pinnacle, Depuy Orthopaedics, Warsaw, In) in patients who have received these implants in the our region. 56 patients were recruited in total. All patients were assessed clinically, radiologically and biochemically. Whole blood Cobalt, Chromium and titanium levels were tested.

The median head size used in the Birmingham group was 52mm (Range 44mm to 56mm), and in the Durom group, 48mm (Range 42 to 54mm). The median head size used in the modular Pinnacle group was 40mm (Range 36–44mm).

The blood metal ions levels in the larger non modular acetabular sockets were significantly raised compared to the Pinnacle group. For Co 1.95 µg/l and 2.70 µg/l in the Durom and Birmingham groups respectively compared to only 0.52 µg/l in the Pinnacle group (P< 0.001). Mean Cr levels were the same for the two monoblock systems, 1.9 µg/l compared to the Pinnacle sockets 1.2 µg/l (P< 0.001).

Our study clearly demonstrates that there is a significant difference in metal ion levels in patients following a monobloc large head arthroplasty system compared to a smaller modular metal on metal hip arthroplasty. The smaller head size appears to produce less metal ions whilst at the same time a 36mm–44mm head size is large enough to increase hip stability and range of movement as well as decreasing the risk of impingement. In our practice we are no longer using this design and the safest strategy, when considering metal on metal bearings, is to use a modular, smaller head system such as the Pinnacle.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 157 - 157
1 Sep 2012
Lee D Powell J Burkart B Smith J Kinniburgh D Faris P Parker R Marshall D Railton P
Full Access

Purpose

To determine whether there is a difference in the metal ion levels among three different metal-on-metal total hip systems: two monoblock large heads and one modular metal-on-metal total hip replacement system in patients who received these implants in our region.

Method

A group of 56 patients were recruited that had either undergone total hip replacement (THR) with a Birmingham resurfacing socket, the Durom resurfacing socket, or a Pinnacle metal-on-metal bearing surface. All patients recruited were at least one year following their surgery in order that their ion levels had reached a steady state.

We reviewed every patient clinically, radiographically as well as biochemically. Blood was obtained for cobalt (Co) and chromium (Cr) levels. Current radiographs were arranged to assess the stability and mechanics of the total hip systems. All patients signed an informed consent and completed three questionnaires, The Western Ontario and McMaster Universities (WOMAC) index, the Short Form 36 (SF36) and UCLA activity score. A Harris Hip score was completed in order to assess individual hip function. Statistical analysis was performed on the collected data to assess whether there were any other potential influence on the mean levels of Co and Cr.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 40 - 40
1 Sep 2012
Oliver MC Railton P Faris P Kinniburgh D Parker R MacKenzie J Werle J Powell J
Full Access

Purpose

Elevated blood metal ions are associated with the early failure of the Hip Resurfacing Arthroplasty. The aim of this study was to analyse our prospective database of Hip Resurfacing Arthroplasty patients, to independently review the outliers with elevated blood metal ions and to determine whether a screening program would be of value at our institution.

Method

In 2004 a ten year prospective longitudinal study was set up to evaluate the clinical effectiveness and safety of Metal on Metal Hip Resurfacings in young, active adults with degenerative hip disease.

Six hundred and four patients have enrolled in this multi-surgeon prospective study with strict inclusion criteria for Hip Resurfacing Arthroplasty. All have received the same implant design. All have completed validated functional outcome questionnaires at baseline, three and six months, then annually. A sub-cohort of 196 patients underwent whole blood chromium and cobalt analysis at the same time periods.

Metal on metal bearings have a running in period of a minimum of six months before a steady state wear pattern is attained. We chose five parts per billion for Cobalt or Chromium as our threshold value. This value corresponds to the workplace exposure limit in the United Kingdom to Cobalt in whole blood. Therefore patients with ion levels greater than five parts per billion after six months were recalled for independent review, including further metal ion analysis.