header advert
Results 1 - 6 of 6
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 75 - 82
1 Jan 2019
Kim J Lee SY Jung JH Kim SW Oh J Park MS Chang H Kim T

Aims

The aim of this study was to evaluate the outcome of spinal instrumentation in haemodialyzed patients with native pyogenic spondylodiscitis. Spinal instrumentation in these patients can be dangerous due to rates of complications and mortality, and biofilm formation on the instrumentation.

Patients and Methods

A total of 134 haemodialyzed patients aged more than 50 years who underwent surgical treatment for pyogenic spondylodiscitis were included in the study. Their mean age was 66.4 years (50 to 83); 66 were male (49.3%) and 68 were female (50.7%). They were divided into two groups according to whether spinal instrumentation was used or not. Propensity score matching was used to attenuate the potential selection bias. The outcome of treatment was compared between these two groups.


Bone & Joint Research
Vol. 6, Issue 5 | Pages 337 - 344
1 May 2017
Kim J Hwang JY Oh JK Park MS Kim SW Chang H Kim T

Objectives

The objective of this study was to assess the association between whole body sagittal balance and risk of falls in elderly patients who have sought treatment for back pain. Balanced spinal sagittal alignment is known to be important for the prevention of falls. However, spinal sagittal imbalance can be markedly compensated by the lower extremities, and whole body sagittal balance including the lower extremities should be assessed to evaluate actual imbalances related to falls.

Methods

Patients over 70 years old who visited an outpatient clinic for back pain treatment and underwent a standing whole-body radiograph were enrolled. Falls were prospectively assessed for 12 months using a monthly fall diary, and patients were divided into fallers and non-fallers according to the history of falls. Radiological parameters from whole-body radiographs and clinical data were compared between the two groups.


Bone & Joint Research
Vol. 5, Issue 11 | Pages 544 - 551
1 Nov 2016
Kim Y Bok DH Chang H Kim SW Park MS Oh JK Kim J Kim T

Objectives

Although vertebroplasty is very effective for relieving acute pain from an osteoporotic vertebral compression fracture, not all patients who undergo vertebroplasty receive the same degree of benefit from the procedure. In order to identify the ideal candidate for vertebroplasty, pre-operative prognostic demographic or clinico-radiological factors need to be identified. The objective of this study was to identify the pre-operative prognostic factors related to the effect of vertebroplasty on acute pain control using a cohort of surgically and non-surgically managed patients.

Patients and Methods

Patients with single-level acute osteoporotic vertebral compression fracture at thoracolumbar junction (T10 to L2) were followed. If the patients were not satisfied with acute pain reduction after a three-week conservative treatment, vertebroplasty was recommended. Pain assessment was carried out at the time of diagnosis, as well as three, four, six, and 12 weeks after the diagnosis. The effect of vertebroplasty, compared with conservative treatment, on back pain (visual analogue score, VAS) was analysed with the use of analysis-of-covariance models that adjusted for pre-operative VAS scores.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 91 - 91
1 Jan 2016
Derasari A Gold J Alexander J Kim SW Patel R Parekh J Incavo S Noble P
Full Access

Introduction

Mechanically-assisted corrosion of the head-neck junction present a dilemma to surgeons at revision THR whenever the femoral component is rigidly fixed to the femur. Many remove the damaged femoral head, clean the femoral taper and fix a new head in place to spare the patient the risks associated with extraction and replacement of the well-functioning femoral stem. This study was performed to answer these research questions:

Will new metal heads restore the mechanical integrity of the original modular junction after impaction on corroded tapers?

Which variables affect the stability of the new interface created at revision THR?

Materials and Methods

Twenty-two tapers (CoCr, n=12; TiAlV, n=10) were obtained for use in this study. Ten stems were in pristine condition, while 12 stems had been retrieved at revision THR and with corrosion damage to the trunnion (Goldberg scale 4). Twenty-two new metal heads were obtained for use in the study, each matching the taper and manufacturer of the original component. The following test states were performed using a MTS Machine: 1. Assembly, 2. Disassembly, 3. Assembly, 4. Toggling and 5. Disassembly. All head assemblies were performed wet using 50% calf serum in accordance to ISO 7206-10. During toggling, each specimen's loading axis was aligned 25° to the trunnion axis in the frontal plane and 10° in the sagittal plane (Figure 1). Toggling was performed at 1Hz for 2,000 cycles with a sinusoidal loading function (230N–4300N). During loading, 3D motion of the head-trunnion junction was measured using a custom jig rigidly attached to the head and the neck of each prosthesis. Relative displacement of the head with respect to the neck was continuously monitored using 6 high resolution displacement transducers with an accuracy of ±0.6µm. Displacement data was independently validated using FEA models of selected constructs.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 134 - 134
1 Mar 2010
Kim SW Limson MA Kim SB Arbatin JJF Park MS Shin JH Ju YS
Full Access

Background: Cervical myelopathy and radiculopathy has been treated commonly with anterior cervical decompression and fusion with autologous bone graft and anterior cervical plating. Long term results have shown excellent pain relief and 73%–90% fusion rates. However, the development of late adjacent-level disease has been reported following anterior cervical arthrodesis which recently have been correlated to clinical findings. The Bryan disc arthroplasty device was developed to preserve the kinematics of the functional spine unit thus preventing adjacent level disease. There have been few studies comparing the incidence of adjacent level changes in patients undergoing ACDF compared to implantation of a Bryan disc arthroplasty device.

Objectives: The object of this study is to compare the clinical results and radiographic outcomes of anterior cervical decompression and fusion versus cervical disc replacement using the Bryan Cervical Disc Prosthesis (Medtronic Sofamor Danek, Memphis, TN) in terms of overall range of motion (ROM) of the cervical spine; ROM, anterior intervertebral height (AIH), posterior intervertebral height (PIH) and radiographic changes at the implanted and adjacent levels.

Methods: The study consisted of 105 patients with symptomatic single or two-level cervical disc disease. Fifty-one received the Bryan Cervical Artificial Disc Prosthesis (Medtronic Sofamor Danek, Memphis, TN). A total of 63 Bryan disc were placed in these 51 patients. A single-level procedure was performed in 39 patients and a two-level procedure in the other twelve. The patient group who underwent ACDF totaled 54 patients which consisted of 26 single level cases and 28 double level cases. The Bryan group had a mean follow-up 19 months (12–38). The mean follow-up for the ACDF group was 20 months (12–40 months). All patients were evaluated using static and dynamic cervical spine radiographs as well as MR imaging.

All patients underwent anterior cervical discectomy followed by anterior cervical plating or implantation of the Bryan artificial disc prosthesis, done by one surgeon. Clinical evaluation included the visual analogue scale (VAS), and neck disability index (NDI). Radiographic evaluation included static and dynamic flexion-extension radiographs in an upright position using the computer software (Infinitt PiviewSTAR 5051) program. Range of motion/disc space angle and inter vertebral height were measured at the operative site and adjacent levels. Functional spinal unit (FSU) and overall sagittal alignment (C2–C7) were also measured pre-operatively, postoperatively and at final follow-up. ROM was calculated for all 3 areas and data collected were compared from pre operative to last follow-up as well as between the two groups. Radiographic assessment for adjacent level changes was also done. Radiologic change was analyzed using chi square test (95% confidence interval). Other data were analyzed using the mixed model. (SAS enterprise guide 4.1 version)

Results: There was clinical improvement within each group in terms of VAS and NDI scores from pre-op to final follow-up for both single (VAS: p=0.8371, NDI: p=0.2872) and double (VAS: p=0.2938, NDI: p=0.6753) level surgeries but not significantly between the two groups. Overall, ROM and intervertebral height was relatively well maintained during the follow-up in the Bryan group compared to ACDF. Comparing the pattern of ROM measurements from pre-op to final follow-up between the two arms regardless of the number of levels operated on; significant differences were noted for overall ROM of the cervical spine (p< .0001) and all other levels except at the upper level for single level surgeries (p=0.2872). In terms of inter vertebral height measurements from pre-op to final follow-up, statistically significant (p< 0.0001 and p=0.0172) differences in the pattern between the two groups were noted at all levels except for the AIH of single level surgeries at the upper (p=0.1264) and lower (p=0.7598) levels as well as PIH for double level surgeries at the upper (p=0.8363) level. Radiologic change was 3.5 times more observed for the ACDF group compared to the Bryan group.

Conclusion: Clinical status of both groups, regardless of the number of levels, showed improvement. Although clinical outcomes between the two groups were not significantly different at final follow-up, radiographic parameters, namely ROM and intervertebral heights at the operated site, some adjacent levels as well as FSU and overall sagittal alignment of the cervical spine were relatively well maintained in our Bryan group compared to our ACDF group. We surmise that to a certain degree, the maintenance of these parameters could contribute to reduce development of adjacent level change. Noteworthy is that radiographic change was 3.5 times more observed for ACDF surgeries. A longer period of evaluation is needed, to see if all these radiographic changes will translate to symptomatic adjacent level disease.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1526 - 1530
1 Nov 2009
Park S Kim SW Jung B Lee HS Kim JS

We reviewed the results of a selective à la carte soft-tissue release operation for recurrent or residual deformity after initial conservative treatment for idiopathic clubfoot by the Ponseti method. Recurrent or residual deformity occurred in 13 (19 feet) of 33 patients (48 feet; 40%). The mean age at surgery was 2.3 years (1.3 to 4) and the mean follow-up was 3.6 years (2 to 5.3). The mean Pirani score had improved from 2.8 to 1.1 points, and the clinical and radiological results were satisfactory in all patients. However, six of the 13 patients (9 of 19 feet) had required further surgery in the form of tibial derotation osteotomy, split anterior tibialis tendon transfer, split posterior tibialis transfer or a combination of these for recurrent deformity.

We concluded that selective soft-tissue release can provide satisfactory early results after failure of initial treatment of clubfoot by the Ponseti method, but long-term follow-up to skeletal maturity will be necessary.