header advert
Results 1 - 8 of 8
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1542 - 1549
1 Dec 2019
Kim JH Ahn JY Jeong SJ Ku NS Choi JY Kim YK Yeom J Song YG

Aims

Spinal tuberculosis (TB) remains an important concern. Although spinal TB often has sequelae such as myelopathy after treatment, the predictive factors affecting such unfavourable outcomes are not yet established. We investigated the clinical manifestations and predictors of unfavourable treatment outcomes in patients with spinal TB.

Patients and Methods

We performed a multicentre retrospective cohort study of patients with spinal TB. Unfavourable outcome was defined according to previous studies. The prognostic factors for unfavourable outcomes as the primary outcome were determined using multivariable logistic regression analysis and a linear mixed model was used to compare time course of inflammatory markers during treatment. A total of 185 patients were included, of whom 59 patients had unfavourable outcomes.


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 703 - 709
1 May 2016
Kim Y Kang HG Kim JH Kim S Lin PP Kim HS

Aims

The purpose of the study was to investigate whether closed intramedullary (IM) nailing with percutaneous cement augmentation is better than conventional closed nailing at relieving pain and suppressing tumours in patients with metastases of the femur and humerus.

Patients and Methods

A total of 43 patients (27 men, 16 women, mean age 63.7 years, standard deviation (sd) 12.2; 21 to 84) underwent closed IM nailing with cement augmentation for long bone metastases. A further 27 patients, who underwent conventional closed IM nailing, served as controls. Pain was assessed using a visual analogue scale (VAS) score pre-operatively (pre-operative VAS), one week post-operatively (immediate post-operative VAS), and at six weeks post-operatively (follow-up post-operative VAS). Progression of the tumour was evaluated in subgroups of patients using F-18-fludeoxyglucose (F-18-FDG) positron emission tomography (PET)/computed tomography (CT) and/or bone scintigraphy (BS), at a mean of 8.8 and 7.2 months post-operatively, respectively.


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1485 - 1490
1 Nov 2014
Kim CW Seo SS Kim JH Roh SM Lee CR

The aim of this study was to find anatomical landmarks for rotational alignment of the tibial component in total knee replacement (TKR) in a CT-based study. Pre-operative CT scanning was performed on 94 South Korean patients (nine men, 85 women, 188 knees) with osteoarthritis of the knee joint prior to TKR. The tibial anteroposterior (AP) axis was defined as a line perpendicular to the femoral surgical transepicondylar axis and passing through the centre of the posterior cruciate ligament (PCL). The angles between the defined tibial AP axis and anatomical landmarks at various levels of the tibia were measured. The mean values of the angles between the defined tibial AP axis and the line connecting the anterior border of the proximal third of the tibia to the centre of the PCL was -0.2° (-17 to 14.1, sd 4.1). This was very close to the defined tibial axis, and remained so regardless of lower limb alignment and the degree of tibial bowing. Therefore, AP axis defined as described, is a reliable anatomical landmark for rotational alignment of tibial components.

Cite this article: Bone Joint J 2014; 96-B:1485–90.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 578 - 582
1 May 2013
Kim S Postigo R Koo S Kim JH

The timing of total hip replacement (THR) in patients with active tuberculosis (TB) of the hip is controversial, because of the potential risk of reactivation of infection. There is little information about the outcome of THR in these patients. We conducted a systematic review of published studies that evaluated the outcome of THR in patients with active TB of the hip. A review of multiple databases referenced articles published between 1950 and 2012. A total of six articles were identified, comprising 65 patients. TB was confirmed histologically in all patients. The mean follow-up was 53.2 months (24 to 108). Antituberculosis treatment continued post-operatively for between six and 15 months, after debridement and THR. One non-compliant patient had reactivation of infection. At the final follow-up the mean Harris hip score was 91.7 (56 to 98). We conclude that THR in patients with active TB of the hip is a safe procedure, providing symptomatic relief and functional improvement if undertaken in association with extensive debridement and appropriate antituberculosis treatment.

Cite this article: Bone Joint J 2013;95-B:578–82.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 224 - 224
1 Mar 2013
Kim JH Kim DG
Full Access

Background

We would like to analyze the risk factors of no thumb test among knee alignment tests during total knee arthroplasty surgery.

Methods

The 156 cases of total knee arthroplasty by an operator from October 2009 to April 2010 were analyzed according to preoperative indicators including body weight, height, degree of varus deformity, and patella subluxation and surgical indicators such as pre-osteotomy patella thickness, degree of patella degeneration, no thumb test which was evaluated after medial prepatella incision and before bone resection (1st test), no thumb test which was evaluated with corrective valgus stress (2nd test, J test), and the kind of prosthesis. We comparatively analyzed indicators affecting no thumb test (3rd test).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_VIII | Pages 58 - 58
1 Mar 2012
Yoon TR Kim HK Kim JH Park DS
Full Access

Introduction

Bone morphogenetic proteins (BMPs) are members of the TGF-beta superfamily of growth factors and are known to regulate proliferation and expression of the differentiated phenotype of chondrocytes, osteoblasts, and osteoclasts. To investigate the osteoblastic differentiation gene expressions that contribute to BMP-7 dependent ostogenesis, we performed gene expression profiling of BMP-7-treated mouse bone marrow stromal cells.

Methods

D1 cells (mouse bone marrow stromal cells) were cultured in osteogenic differentiation medium (ODM) for 3 days, and then treated with BMP-7 for 24 hr. Total RNA was extracted using Trizol, purified using RNeasy columns. Total RNA was amplified and purified using the Ambion Illumina RNA amplification kit to yield biotinylated cRNA. The data analysis up- and down-regulation developmental processes (anterior/posterior patterning, ectoderm development, embryogenesis, gametogenesis, mesoderm development, other development process, and segment specification) genes expression fold.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1587 - 1593
1 Dec 2009
Oh JH Kim SH Kim JH Shin YH Yoon JP Oh CH

This study examined the role of vitamin D as a factor accounting for fatty degeneration and muscle function in the rotator cuff. There were 366 patients with disorders of the shoulder. A total of 228 patients had a full-thickness tear (group 1) and 138 patients had no tear (group 2). All underwent magnetic resonance arthrography and an isokinetic muscle performance test. The serum concentrations of vitamin D (25(OH)D3) were measured.

In general, a lower serum level of vitamin D was related to higher fatty degeneration in the muscles of the cuff. Spearman’s correlation coefficients were 0.173 (p = 0.001), −0.181 (p = 0.001), and −0.117 (p = 0.026) for supraspinatus, infraspinatus and subscapularis, respectively. In group 1, multivariate linear regression analysis revealed that the serum level of vitamin D was an independent variable for fatty degeneration of the supraspinatus and infraspinatus.

The serum vitamin D level has a significant negative correlation with the fatty degeneration of the cuff muscle and a positive correlation with isokinetic muscle torque.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 7 | Pages 1029 - 1033
1 Sep 2001
Jung JM Baek GH Kim JH Lee YH Chung MS

We studied radiographs of the wrists of 120 healthy volunteers in order to determine the normal range of ulnar variance. They had been taken in various positions under both unloaded (static) and loaded (dynamic) conditions. Pronation posteroanterior, supination anteroposterior and neutral posteroanterior views were taken of each wrist before and during a maximum grip under identical conditions. The mean normal ulnar variance in neutral rotation was +0.74 ± 1.46 mm, a value which was significantly lower in males than in females. We found negative variance in 26% of cases. We measured maximum ulnar variance (UVmax, +1.52 ± 1.56 mm) when gripping in pronation and minimum ulnar variance (UVmin, +0.19 ± 1.43 mm) when relaxed in supination. We subtracted UVmin from UVmax to calculate a mean maximum dynamic change in ulnar variance of 1.34 ± 0.53 mm. We consider this database of normal values to be useful for both the diagnosis and treatment of conditions related to discrepancy in radio-ulnar length and for clinical research.