header advert
Results 1 - 20 of 44
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 32 - 32
1 May 2021
Heylen J Rossiter D Khaleel A Elliott D
Full Access

Introduction

Pilon fractures are complex, high-energy, intra-articular fractures of the distal tibia. Achieving good outcomes is challenging due to fracture complexity and extensive soft tissue damage.

The purpose of this study was to determine the long-term functional and clinical outcomes of definitive management with fine wire Ilizarov fixation for closed pilon fractures.

Materials and Methods

185 patients treated over a 14-year period (2004–2018) were included. All patients had Ilizarov frames applied to restore mechanical axis and fine wires to control periarticular fragments. CT scans were performed post operatively to confirm satisfactory restoration of the articular surface. All frames were dynamized prior to removal.

Patients' functional outcome was assessed using the validated Chertsey Outcome Score for Trauma (“COST”). Review of clinical notes and imaging was used to determine complications and time to union.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 39 - 39
1 May 2018
Gee C Agarwal S Iliopoulos E Khaleel A
Full Access

Introduction

Anatomical reduction of articular fragments in tibial plateau fractures often leads to a void and there is a need to fill dead space and support the articular fragment. MIIG X3 is marketed as high strength injectable graft, which resorbs and remodels fast. Efficacy and complications related to the use of this bone graft substitute were evaluated in this study

Methods

Between January 2012 and December 2016 we injected calcium sulphate (MIIGX3) in 50 out of 126 consecutive complete articular (AO type C3) tibial plateau fractures that were stabilised with Ilizarov ring fixator. Postoperative CT scans after weight bearing and sequential radiographs were evaluated for union, graft resorption and subsidence. IOWA functional outcome score and complications were recorded.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 24 - 24
1 May 2018
Iliopoulos E Agarwal S Khaleel A
Full Access

Purpose

Pilon fracture is a severe injury which has a great impact on the patients' lives, but in what extend is not clear yet in the literature. The purpose of this study was to investigate the gait alternations after treatment of patients who had pilon fractures.

Materials & Methods

We have evaluated the gait pattern of patients who were treated with circular Ilizarov frame following pilon fractures in our department. The gait was tested by using a force plate in a walking platform. Ground Reaction Forces (GRF) and timing of gait phases data were collected during level walking at self-selected speeds. The patients performed two walking tasks for each limb and the collected data were averaged for each limb. Demographic, clinical, radiological, trauma outcome (COST) and quality of life questionnaire (SF-12) data were also collected.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 37 - 37
1 May 2018
Jukes C Stone A Oliver-Welsh L Khaleel A
Full Access

Background

Humerus fracture non-union is a challenge for which a wide range of treatments exist. We present our experience of managing these by hybrid Ilizarov frame fixation, without bone graft or debridement of the non-union site.

Methods

Case notes review of a consecutive series of 20 patients treated for aseptic humeral non-union between 2004 and 2016. Eighteen patients had previous plate or intramedullary nail fixations, and 2 had no prior surgery. During Ilizarov application, any existing metalwork preventing dynamisation of the fracture site was removed through minimal incisions before compression of the fracture site was then achieved. Only 3 patients had open debridement or osteotomy of the non-union site, otherwise all other patients had no debridement of their non-union.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 10 - 10
1 May 2018
Gee C Dimock R Nutt J Stone A Jukes C Kontoghiorghe C Khaleel A
Full Access

Introduction

Our unit has extensive experience with the use of Ilizarov circular frames for acute fracture and nonunion surgery. We have observed and analysed fracture healing patterns which question the role of relative stability in fracture healing and we offer limb mechanical axis restoration as a more important determinant.

Aim

To assess for the presence of external callus, when only relative stability has been achieved but with anatomical restoration of the mechanical axis (ARMA).


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 17 - 17
1 May 2018
Kontoghiorghe C Khaleel A
Full Access

Background

The circular Ilizarov frame is a well-established method of external fixation used in the acute treatment of fractures. In our unit, based on our experience, we have changed practice from an all-wire construct to a hybrid, incorporating one 5mm titanium half-pin in the distal reference construct. We were able to compare the all-wire construct against this hybrid in terms of time to union and complications.

Methods

All patients who underwent circular frame fixation between 2009 and 2016 for Schatzker IV-VI tibial plateau fractures at one district general hospital were included in the study. The date of union was noted and time to union was calculated.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 23 - 23
1 May 2018
Dimock R Gee C Khaleel A
Full Access

Aim

Circular frames are used to treat a wide spectrum of acute injuries and deformities. We report on our experience of treating both acute and chronic trimalleolar fracture dislocations with a closed technique, utilizing fine wires and a circular frame.

Methods

Data was collected from all patients treated for either acute or chronic trimalleolar fracture dislocations at a single centre between January 2016 and December 2017. A total of 10 patients were identified, 8 with acute injuries and 2 with chronic/delayed injuries. Clinical and radiological outcomes were recorded, as well as patient reported outcome measures (PROMs) using the Chertsey Outcome Score for Trauma (COST score).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_21 | Pages 2 - 2
1 Dec 2017
Agarwal S Iliopoulos E Khaleel A
Full Access

Aim

Anatomical reduction and Stable fixation of Lisfranc injuries is considered the gold standard. There is controversy about how it is best achieved. Some surgeons would advocate routine open anatomical reduction, which as a concept was popular in 1980s but the same anatomical reduction and fixation can be achieved percutaneously. We describe our method of close reduction and percutaneous fixation and present our results.

Materials and methods

22 patients with a minimum follow up of 12 months were included. We achieved satisfactory anatomical reduction percutaneously in all patients and internal fixation was performed using cannulated screws for medial and middle columns. Functional outcome was evaluated using Foot and Ankle Disability Index (FADI) and components of this score were analysed individually to assess which domain was most affected. Vertical ground reaction forces were measured using a force plate in a walking platform.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_13 | Pages 3 - 3
1 Jun 2017
Iliopoulos E Agarwal S Gallagher K Khaleel A
Full Access

Purpose

Tibia plateau fractures are severe knee injuries which have a great impact on the patients' lives, but in what extend is not clear yet in the literature. The purpose of this study was to investigate the gait alternations after treatment of patients who had severe tibia plateau fractures which were treated with circular ilizarov frame.

Materials & Methods

We have evaluated the gait pattern of patients who were treated with circular Ilizarov frame after severe tibia plateau fractures (Schatzker IV-VI) in our department. The gait was tested by using a force plate in a walking platform. Ground Reaction Forces (GRF) data were collected during level walking at self-selected speeds. The patients performed two walking tasks for each limb and the collected data were averaged for each limb. Demographic, clinical, radiological and quality of life questionnaire (SF-12) data were also collected.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_13 | Pages 2 - 2
1 Jun 2017
Iliopoulos E Agarwal S Khaleel A
Full Access

Introduction

Patient Reported Outcome Measures (PROMs) are used as outcome of many surgical treatments such as Hip and knee joint replacements, varicose vein and groin hernia surgery. Outcome scores in orthopaedics tend to be site and/or pathology specific. Trauma related pathology uses a surrogate outcome scores. A unified outcome score for trauma is needed to help with the measurement of outcomes in trauma patients and evaluate the actual impact that trauma inflicts to patients' lives.

Materials & Methods

We have designed a PROM especially for Trauma patients, in order to measure the extent of recovery to pre-injury state. This score uses as baseline the pre-injury status of the patient and has the aim to determine the percentage of rehabilitation after any form of treatment. This PROM is not site specific and can be used for every Trauma condition. It uses simple wording, user friendly and accessed via phone conversation.

The outcome score consists of eleven questions. The first ten questions use the 5-point Likert scale and the final question a scale from zero to ten. The questions are divided into three subgroups (Symptoms, Function and Mental status). The final question assesses the extent of return to pre-injury status.

The SF-12v2 questionnaire was used for the validation of the COST questionnaire. We gathered COST and SF-12v2 questionnaires from patients who were at the end of their follow-up after treatment for various trauma conditions, treated either conservatively either operatively.


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1693 - 1697
1 Dec 2015
Keightley AJ Nawaz SZ Jacob JT Unnithan A Elliott DS Khaleel A

This study aimed to determine the long-term functional, clinical and radiological outcomes in patients with Schatzker IV to VI fractures of the tibial plateau treated with an Ilizarov frame. Clinical, functional and radiological assessment was carried out at a minimum of one year post-operatively. A cohort of 105 patients (62 men, 43 women) with a mean age of 49 years (15 to 87) and a mean follow-up of 7.8 years (1 to 19) were reviewed. There were 18 type IV, 10 type V and 77 type VI fractures. All fractures united with a mean time to union of 20.1 weeks (10.6 to 42.3). No patient developed a deep infection. The median range of movement (ROM) of the knee was 110o and the median Iowa score was 85.

Our study demonstrates good long-term functional outcome with no deep infection; spanning the knee had no detrimental effect on the ROM or functional outcome.

High-energy fractures of the tibial plateau may be treated effectively with a fine wire Ilizarov fixator.

Cite this article: Bone Joint J 2015;97-B:1693–7.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_5 | Pages 24 - 24
1 May 2015
Casey R Khaleel A
Full Access

Background

The Schatzker classification is applied in the management of tibial plateau fractures. The unique pattern of Schatzker VI fractures requires recognition for proper fixation.

Method:

We have treated 33 patients with Schatzker IV tibial plateau fractures including non-unions and mal-unions. Patients had a temporary spanning Ilizarov frame with intraoperative distraction, articular reconstruction and olive wires for indirect reduction. No open surgery was performed. Patients mobilised fully weight-bearing and underwent post-operative CT scan and regular outpatient reviews. At six weeks the femoral ring was removed, and patients underwent a staged dynamisation protocol prior to frame removal.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_5 | Pages 6 - 6
1 May 2015
Boyd R Khaleel A Beckles V
Full Access

Background:

Charcot arthropathy is a condition related to the loss of protective sensation of a joint. It normally presents in its early inflammatory phase, followed by bone destruction. Recognised treatment for this is total contact casting (TCC). However, in a small group this may be unsuccessful in preventing deformity progression. TCC can also be difficult in the presence of recalcitrant ulceration and deformed feet.

Method:

40 patients, with a diagnosis of Charcot foot, were followed from presentation in our unit over 3 years. An Ilizarov frame was used for two groups: those in the early phase who showed progressive deformity despite TCC (5 patients) and those with chronic ulceration (4 patients). Frames were modified to allow weight-bearing on the frame (with no foot contact). All other patents were treated with TCC.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_5 | Pages 20 - 20
1 May 2015
Unnithan A Jacob J Khaleel A
Full Access

Background:

The aim of this study was to review the surgical complications and clinical outcomes of patients with Pilon fractures treated with Ilizarov frames.

Methods:

Data collected included surgical complications, grade of initial injury using the Ruedi-Allgower classification and quality of reduction according to the Teeny and Wiss criteria. Outcome scores were collected retrospectively using the Foot and Ankle Disability Index (FADI).


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_10 | Pages 27 - 27
1 Jul 2014
Unnithan A Jabbar Y Khaleel A
Full Access

Shear plane non unions: biomechanical study and clinical application using an all wire Illizarov frame.

60 degree osteotomy of plastic tibiae were stabilised using four different Ilizarov frame configurations.

Models were loaded and shear displacement measured at the fracture site. The optimum frame design was identified and used in clinical practice.

The transfracture locked olive wire frame model offered the least displacement in the experimental model This frame model was used in two patients with shear plane non unions and both healed satisfactorily Both displacements had previously failed to unite with standard frame constructs.

Transfracture locked olive wire frame design is useful in the treatment of tibial non unions with shear plane.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_10 | Pages 10 - 10
1 Jul 2014
Keightley A Nawaz S Elliott D Khaleel A
Full Access

The purpose of this study was to review the long term functional results of patients undergoing treatment for high energy tibial plateau fractures.

Between January 1994 and June 2013 our unit managed 105 high energy tibial plateau fractures (Schatzker IV-VI) with an Ilizarov frame. All cases were treated via ligamentotaxis and percutaneous fine wire fixation or with a limited open reduction of the joint surface. A retrospective analysis of all patients that have undergone Ilizarov fixation of a tibial plateau fracture was performed with radiological and clinical functional outcome measurements.

We analysed 105 patients with a mean follow up of 93.5 months (range 5–200). The patient group had an average age of 49 years (range 15–87) with 62 patients being male. Fracture pattern was analysed with Schatzker's classification showing 18 type IV, 10 type V and 77 type VI tibial plateau fractures. All fractures had an average time to union of 145 days. Patients had and average range of movement of 117 degrees.

Patients undergoing Ilizarov treatment for high energy tibial plateau fractures achieve successful results long term. Definitive treatment should be decided with respect to fracture pattern and the soft tissue envelope. The management aim should be to achieve anatomical reduction and stable fixation to enable early mobilization. Our study confirms the good functional outcomes and low morbidity that can be achieved in high energy fractures treated with Ilizarov fixation.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_23 | Pages 27 - 27
1 May 2013
Keightley A Gurdezi S Scott N Khaleel A
Full Access

The purpose of this study was to assess the impact of Ilizarov frame fixation and total contact casting on the complications of Charcot arthropathy.

The diabetic charcot foot or ankle is a potentially limb threatening disorder. This progressive disorder is characterised by osteopenia, bone fragmentation and joint subluxation. The risk of significant deformity and osteomyelitis lead to high rates of amputation in these patients.

We analysed patients with acute charcot arthropathy attending the Rowley Bristow Unit between 2008 and 2012. We assessed 48 patients with a mean age of 59 years. Mean follow up was 24 months. 12 patients were managed with Ilizarov frame fixation and 36 using total contact casting. The duration of management was determined using serial infrared temperature monitoring to ensure the temperature of the limb normalised before patients were deemed safe to remove their immobilisation. The mean duration of Iliazarov frame fixation was 6.2 months and 5.3 months duration for total contact casting. In the Ilizarov group pin site infections were common and treated with a short course of antibiotics. In total one patient required below knee amputation following Ilizarov frame fixation. No patients suffered with osteomyelitis.

We feel that prompt management of acute charcot arthropathy with either total contact casting where appropriate or Ilizarov frame fixation can reduce serious complications of this disorder.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 157 - 157
1 Jan 2013
Nawaz S Keightley A Elliott D Newman K Khaleel A
Full Access

Currently the debate continues in definitive fixation method for complex tibial plateau fractures. The aim of surgical management remains prevention of further damage to the articular cartilage, whilst avoiding iatrogenic risks - Low Risk Surgery (LRS). The purpose of this study was to determine the functional impact, clinical radiological outcome following tibial plateau fractures treated with either external fixation or internal fixation.

124 Schatzker IV-VI tibial plateau fractures were reviewed following surgical fixation. Fractures analysed included 24 type IV, 20 type V and 80 type VI tibial plateau fractures. The majority of Schatzker IV fractures were treated with internal fixation, but 67 of 80 Schatzker VI fractures were treated with the Ilizarov method. The average IOWA knee score, was 86 (16 to 100) and the average range of motion was 133 degrees (60 to 150). There were no differences between the circular fixator group and the internal fixation group in terms of range of motion or IOWA scores. There were comparable functional outcomes and complication rates between both groups.

In summary patients with high energy tibial plateau fracture treated with internal or external fixation, have a good chance of achieving satisfactory long term knee function.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 155 - 155
1 Apr 2012
Farook M Raison N Alwan W Abbott A Mohammed R Khaleel A Schofield C
Full Access

Back pain affects 70% of the population in developed countries and accounts for 13% of sickness absence in the United Kingdom1. The clinical presentation might be taken less seriously and could result in significant morbidity and mortality. We did a retrospective observational study of patients admitted on an “acute” basis in our unit. Our aim was to identify the epidemiological proportion of patients who had significant life changing spinal conditions.

239 patients were admitted between January 2004 to December 2008 who presented with non traumatic back pain and related symptoms. The group of patients who had osteoporotic compression fractures were excluded. The mean age was 53.6 and patients were predominantly females. Disc protrusions and degenerative conditions accounted for majority of the patients. Cauda Equina Syndrome (CES) and Cord compressions together contributed to 7.9% and 8.7% respectively. The mean length of stay was 10.4 days and the average wait for MRI scan was 2.4 days.

Among the patients who present with back pain in the primary care setting, 3% have disc protrusions and 1% neoplastic lesions1. But the epidemiological distribution among the back pain admissions in the hospital setting is not very clear. Medico legal costs especially with CES are quite substantial2 and hence it would be useful to know the volume of patients with potential disabling lesions.

Our study reveals that a significant proportion of patients who had to be admitted with back pain and especially those having red flag signs have serious spinal pathologies. Early diagnosis and timely intervention could prevent unwarranted morbidity and mortality.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 44 - 44
1 Feb 2012
Tilkeridis K Khaleel A Cheema N
Full Access

We report our experience of a humanitarian mission to treat the earthquake victims of October 2005 in Pakistan. The team with their equipment, in two periods of four and ten days respectively, treated 26 fractures in 25 patients with the Ilizarov frame and principles. There were 21 III B open fractures and three Tscherne III closed fractures. Seventeen fractures were infected with discharging pus and non-viable bone. Injuries were treated aggressively using different Ilizarov techniques of reconstruction surgery. All but two open fractures required a plastic surgical procedure for wound cover. Three months post-operatively eight out of thirteen fractures which had been treated in the first four days of the visit were healed and corticotomy for bone lengthening, performed during the second 10 days period visit. All wounds have remained clean with no evidence of superficial or deep infection. Limb lengthening procedures are planned for the rest of the patients.