header advert
Results 1 - 15 of 15
Results per page:
Bone & Joint Open
Vol. 4, Issue 8 | Pages 559 - 566
1 Aug 2023
Hillier DI Petrie MJ Harrison TP Salih S Gordon A Buckley SC Kerry RM Hamer A

Aims

The burden of revision total hip arthroplasty (rTHA) continues to grow. The surgery is complex and associated with significant costs. Regional rTHA networks have been proposed to improve outcomes and to reduce re-revisions, and therefore costs. The aim of this study was to accurately quantify the cost and reimbursement for a rTHA service, and to assess the financial impact of case complexity at a tertiary referral centre within the NHS.

Methods

A retrospective analysis of all revision hip procedures was performed at this centre over two consecutive financial years (2018 to 2020). Cases were classified according to the Revision Hip Complexity Classification (RHCC) and whether they were infected or non-infected. Patients with an American Society of Anesthesiologists (ASA) grade ≥ III or BMI ≥ 40 kg/m2 are considered “high risk” by the RHCC. Costs were calculated using the Patient Level Information and Costing System (PLICS), and remuneration based on Healthcare Resource Groups (HRG) data. The primary outcome was the financial difference between tariff and cost per patient episode.


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1499 - 1454
1 Nov 2018
Green CM Buckley SC Hamer AJ Kerry RM Harrison TP

Aims

The management of acetabular defects at the time of revision hip arthroplasty surgery is a challenge. This study presents the results of a long-term follow-up study of the use of irradiated allograft bone in acetabular reconstruction.

Patients and Methods

Between 1990 and 2000, 123 hips in 110 patients underwent acetabular reconstruction for aseptic loosening, using impaction bone grafting with frozen, irradiated, and morsellized femoral heads and a cemented acetabular component. A total of 55 men and 55 women with a mean age of 64.3 years (26 to 97) at the time of revision surgery are included in this study.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1419 - 1423
1 Nov 2009
Emms NW Buckley SC Stockley I Hamer AJ Kerry RM

Between 1990 and 2000, 123 hips in 110 patients were reconstructed for aseptic loosening using impaction bone grafting with frozen, irradiated, morsellised femoral heads and cemented acetabular components. This series was reported previously at a mean follow-up of five years. We have extended this follow-up and now describe the outcome of 86 hips in 74 patients at a mean of ten years. There have been 19 revisions, comprising nine for infection, seven for aseptic loosening and three for dislocation. In surviving acetabular reconstructions, union of the graft had occurred in 64 of 67 hips (95.5%).

Survival analysis for all indications at ten years was 83.3% (95% confidence interval (CI) 68 to 89) and 71.3% (95% CI 58 to 84) at 15 years.

Acetabular reconstruction using irradiated allograft and a cemented acetabular component is an effective method of reconstruction, providing results in the medium- to long-term comparable with those of reported series where non-irradiated freshly-frozen bone was used.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 538 - 538
1 Aug 2008
Manning V Buckley SC Kerry RM Stockley I Hamer AJ
Full Access

Aims: Dislocation is one of the commonest complications following total hip arthroplasty. A significant proportion of these patients go on to have recurrent dislocations. Many factors have been identified as contributing to the risk of dislocation but treatment of recurrent dislocation is challenging. The use of semicaptive acetabular components is a potential solution to the problem of recurrent dislocation but there are few studies into the efficacy of these implants.

Methods: Patients who underwent revision of their total hip arthroplasty to a semi-captive socket at the Lower Limb Arthroplasty Unit, Northern General Hospital, Sheffield between 2001 and March 2006 were studied. A proforma was designed and data was obtained from patients’ medical records. The number of dislocations both prior to revision to a semi-captive component and the following revision to a semi-captive acetabular component were recorded including the method of reduction Reasons for revision and the number and reasons for previous revisions were noted.

Results: Average time of follow up was 22 months (range 2 months – 5 years 1 month). Following revision of total hip arthroplasty to a semi-captive component, 78% suffered no further dislocations. Of those patients who went on to redislocate, three went on to have recurrent dislocations and all were reduced by closed reduction. One patient redislocated and underwent a second revision to a semi-captive acetabular component, which was successful and underwent no further dislocations.

Discussion. The results of this study show the use of semicaptive acetabular components in revision surgery for dislocation following total hip arthroplasty to be a highly effective solution to the problem of recurrent dislocation.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 297 - 297
1 Jul 2008
Chadwick C Parsons HK Norman P Kerry RM
Full Access

Introduction: Deep infection is a devastating complication following hip arthroplasty. In the early 1970’s Staphylococcus Aureus (SA) was believed to be the causative organism in most cases and Coagulase Negative Staphylococccus (CNS) was widely regarded as a contaminant. It subsequently became recognised that the majority of infections are caused by CNS rather than SA, probably due to the use of peri-operative antimicrobial agents and laminar air flow in theatre.

Aims: The aim of this study was to look at the causative organisms in patients with an infected total hip replacement to see if the pattern of infection has changed with time.

Methods: Between February 1999 and November 2004, 95 patients underwent 1st stage revision surgery at the Northern General Hospital for definite infection following total hip replacement. At least 5 tissue samples were taken at the time of surgery prior to antibiotic administration. Infection was confirmed when at least 3 of the samples were positive on microbiological culture. We retrospectively reviewed the records of these patients and identified the causative organisms.

Results: The 95 patients were infected with 130 different organisms. Of these 32% were SA including MRSA (7.2%), 27% CNS, 13.6% Enterococcus, 4.8% pseudomonas and 3.2% Streptococcci. 29% of patients had polymicrobial infection.

Discussion: Data published in the literature as well as historical data from our unit suggest that CNS is by far the most common organism causing prosthetic hip joint infection. Our results however, show a recent decrease in the proportion of CNS and an increase in SA and polymicrobial infection.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 574 - 578
1 May 2008
Carroll FA Hoad-Reddick DA Kerry RM Stockley I

Between 1980 and 2000, 63 support rings were used in the management of acetabular deficiency in a series of 60 patients, with a mean follow-up of 8.75 years (2 months to 23.8 years). There was a minimum five-year follow-up for successful reconstructions. The indication for revision surgery was aseptic loosening in 30 cases and infection in 33. All cases were Paprosky III defects; IIIA in 33 patients (52.4%) and IIIB in 30 (47.6%), including four with pelvic dissociation. A total of 26 patients (43.3%) have died since surgery, and 34 (56.7%) remain under clinical review. With acetabular revision for infection or aseptic loosening as the definition of failure, we report success in 53 (84%) of the reconstructions. A total of 12 failures (19%) required further surgery, four (6.3%) for aseptic loosening of the acetabular construct, six (9.5%) for recurrent infection and two (3.2%) for recurrent dislocation requiring captive components. Complications, seen in 11 patients (18.3%), included six femoral or sciatic neuropraxias which all resolved, one grade III heterotopic ossification, one on-table acetabular revision for instability, and three early post-operative dislocations managed by manipulation under anaesthesia, with no further instability.

We recommend support rings and morcellised bone graft for significant acetabular bone deficiency that cannot be reconstructed using mesh.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 455 - 459
1 Apr 2006
Shetty NR Hamer AJ Kerry RM Stockley I Eastell R Wilkinson JM

The aims of this study were to examine the repeatability of measurements of bone mineral density (BMD) around a cemented polyethylene Charnley acetabular component using dual-energy x-ray absorptiometry and to determine the longitudinal pattern of change in BMD during the first 24 months after surgery.

The precision of measurements of BMD in 19 subjects ranged from 7.7% to 10.8% between regions, using a four-region-of-interest model. A longitudinal study of 27 patients demonstrated a transient decrease in net pelvic BMD during the first 12 months, which recovered to baseline at 24 months. The BMD in the region medial to the dome of the component reduced by between 7% and 10% during the first three months, but recovered to approximately baseline values by two years.

Changes in BMD in the pelvis around cemented acetabular components may be measured using dual-energy x-ray absorptiometry. Bone loss after insertion of a cemented Charnley acetabular component is small, transient and occurs mainly at the medial wall of the acetabulum. After two years, bone mass returns to baseline values, with a pattern suggesting a uniform transmission of load to the acetabulum.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 310 - 313
1 Mar 2005
Buckley SC Stockley I Hamer AJ Kerry RM

We report the results of the revision of 123 acetabular components for aseptic loosening treated by impaction bone grafting using frozen, morsellised, irradiated femoral heads and cemented sockets. This is the first large series using this technique to be reported. A survivorship of 88% with revision as the end-point after a mean of five years is comparable with that of other series.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 69 - 69
1 Jan 2004
Ali F Kerry RM Cooper R Wilkinson JM Norman PA Stockley I
Full Access

Purpose: The role of hip aspiration as a preoperative investigation for the painful hip remains controversial. Since 1999, we have performed hip aspiration under local anaesthetics in the X-ray department. This paper reviews our experience with this technique.

Results: Hip aspirations were carried out subsequently on 182 patients from November 1999 to November 2002. Out of 68 patients that underwent revision hip surgery, 63 were included in the study. Three of the five patients excluded had received antibiotics at induction prior to obtaining the operative samples and two did not have any operative samples taken at the time of surgery. Fifteen (23.8%) of the 63 hips were found to be infected based on operative tissue cultures. The sensitivity and specificity of the test were 80% and 87.5%, respectively. Positive and negative predictive values were 66.6% and 93.3% respectively and the accuracy was 85.7%.

Conclusion: Hip aspiration in the Radiology department is a simple, cost effective and reliable preoperative test when used selectively. When used in combination with other laboratory and radiological investigation it can act as an important preoperative investigation in the diagnosis of sepsis. There is an added advantage of identifying the microorganism along with its antibiotic sensitivities. This can guide clinicians in choosing the correct antibiotic for the cement and also for the postoperative antibiotic therapy.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 72 - 72
1 Jan 2004
Aspinall GR Nicholls A Kerry RM Hamer AJ Stockley I
Full Access

The Huckstep ( Bbraun Medical) interlocking hip prosthesis has been used in the Sheffield Lower Limb Arthroplasty Unit in cases of complex primary and revision hip arthroplasty since 1996. We reviewed the outcomes in cases performed prior to October 2001.

Eighty cases were identified. Of these, eight died within one year of surgery, four of which were in the peri operative period. A further thirteen were lost to follow up in the first year due to medical deterioration, move from area or refusal to attend. The remaining 57 patients had a mean time to follow up of 34 months (12–81m).

As a primary prosthesis the Huckstep was used to allow corrective osteotomy. In revision cases it was employed to bypass periprosthetic fractures and fragile proximal femoral bone, in cases requiring extended trochanteric osteotomy to facilitate cement removal, and to enable use of bulk proximal femoral allograft. The use of the Huckstep was planned pre operatively in 67 cases and as a salvage option in 13.The design of the implant allowed a stable construct without the need for bone cement which could interpose and prevent bone healing or graft incorporation. It avoids problems incurred in pressurising cement or impaction grafting against fragile bone.

Complications included infection requiring further surgery (5), dislocation (5), periprosthetic fracture (2), screw breakage (4), and mechanical failure (2). Eleven patients required further revision surgery. The apparently high complication rate reflects the complex nature of the surgery and the high degree of co morbidity in the elderly patient group.

In conclusion, we have found the Huckstep hip prosthesis to be a useful option in cases of complex hip surgery. Whilst the long term outcome is as yet unknown, our short term results show it to have allowed healing of fractures, osteotomy sites and cortical defects, allograft incorporation and replenishing of bone stock, hence facilitating further arthroplasty surgery.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 152 - 152
1 Jul 2002
Taggart T Kerry RM Stockley I Norman P
Full Access

The incidence of infection after primary arthroplasty is low. However, with the increasing number of arthroplasties being performed the prevalence of infection is increasing. The pattern of infecting organisms following total joint arthroplasty has changed and gentamicin resistant organisms are becoming increasingly common. Vancomycin added to bone a cement carrier can, with adequate surgical debridement be very effective in the eradication of established resistant infection. We report the results of its use in 33 patients with 26 infected hip and 7 infected knee arthroplasies. 32 patients remain clinically and radiologically free of infection after a mean follow-up of 67 months. There was one recurrence of infection and there were three positive second stage cultures of uncertain significance. Vancomycin is potentially a very useful tool in the management of deep infection following arthroplasty surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 70 - 72
1 Jan 2002
Taggart T Kerry RM Norman P Stockley I

Although the incidence of infection associated with hip and knee prostheses is low, with the increasing number of arthroplasties being carried out, the total number of such cases is increasing. The pattern of infecting organisms after total joint arthroplasty has changed and gentamicin-resistant organisms are becoming increasingly common. In conjunction with surgical debridement, vancomycin added to a bone-cement carrier can be very effective in the treatment of infection caused by such organisms.

We report the results of its use in proven deep infection in 26 hip and seven knee arthroplasties. After a mean follow-up of 67 months, 32 patients remained clinically and radiologically free from infection. There was one recurrence and positive second-stage cultures of uncertain significance in three other patients. Vancomycin is potentially very useful in the management of deep infection after arthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 2 | Pages 183 - 184
1 Mar 2001
Bruce ASW Kerry RM Norman P Stockley I

We report two cases of fungal infection of prosthetic joints which were successfully treated by the incorporation of fluconazole into polymethylmethacrylate beads inserted at the time of debridement.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 485 - 487
1 May 1999
Kerry RM Masri BA Beauchamp CP Duncan CP

We describe a U-shaped approach to the distal femur which, having divided the extensor mechanism and elevated the entire quadriceps muscle, gives excellent exposure and allows a number of reconstructive options. It was used in 14 patients, 13 of whom were followed up for a mean of 3.5 years (1 to 11). There was no case of flap necrosis, and complications related to the reconstruction were acceptable.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 1 | Pages 78 - 82
1 Jan 1998
Kerry RM Simonds GW

Over a 20-year period we treated 29 patients (31 dislocated hips) by non-operative reduction after nine months of age, using horizontal traction. They were followed up for a mean of 11.7 years, and 12 hips required secondary extra-articular surgery.

The clinical result was excellent in 25 hips, good in four and fair in two. Of the 29 hips for which detailed radiographs were available, 18 achieved Severin grade I, nine grade II and two grade III. There were no major complications and, in particular, no cases of avascular necrosis.

The non-operative reduction of late-presenting developmental dysplasia of the hip is still a viable option. It has a potential for excellent results and a very low complication rate.