header advert
Results 1 - 2 of 2
Results per page:
Bone & Joint Research
Vol. 10, Issue 5 | Pages 298 - 306
1 May 2021
Dolkart O Kazum E Rosenthal Y Sher O Morag G Yakobson E Chechik O Maman E

Aims

Rotator cuff (RC) tears are common musculoskeletal injuries which often require surgical intervention. Noninvasive pulsed electromagnetic field (PEMF) devices have been approved for treatment of long-bone fracture nonunions and as an adjunct to lumbar and cervical spine fusion surgery. This study aimed to assess the effect of continuous PEMF on postoperative RC healing in a rat RC repair model.

Methods

A total of 30 Wistar rats underwent acute bilateral supraspinatus tear and repair. A miniaturized electromagnetic device (MED) was implanted at the right shoulder and generated focused PEMF therapy. The animals’ left shoulders served as controls. Biomechanical, histological, and bone properties were assessed at three and six weeks.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 18 - 18
1 Nov 2018
Kazum E Dolkart O Rozental Y Sherman H Amar E Salai M Maman E Chechik O
Full Access

Drilling through bone is a complex action that requires precise motor skills of an orthopedic surgeon. In order to minimize plunging and soft tissue damage, the surgeon must halt drill progression precisely following penetration of the far cortex. The purpose of this study was to create a low-cost and easy-to-use drilling simulator to train orthopedic residents in reducing the drill plunging depth. This prospective observational study was performed in the division of orthopedic surgery of a single tertiary medical center. The participants included 13 residents and 7 orthopedic specialists. The simulator consisted of a synthetic femur bone model and ordinary modeling clay, and the training unit consisted of a disposable plastic tube (∼US$14), clamps (∼US$58) and a power drill + drill bit (standard hospital equipment). Plunging depths were measured by the simulator and compared between orthopedic specialists, the 6 “senior residents” (3+ years) and the 7 “junior residents” during a training session. Measurements were taken again 2 weeks following the training session. Initially, the plunging depths of the junior residents were significantly greater compared to those of the orthopedic specialists (7.00 mm vs 5.28 mm, respectively, p < 0.038). There was no similarly significant difference between the senior residents and the orthopedic experts ([6.33 mm vs. 5.28 mm, respectively; p = 0.18). The senior residents achieved plunging depths of 5.17 mm at the end of the training session and 4.7 mm 2 weeks later compared to 7.14 mm at the end of the training session and 6 mm 2 weeks later for the junior residents. This study demonstrated the capability of a low-cost drilling simulator as a training model for reducing the plunging depth during the drilling of bone and soft tissue among junior and senior residents.