header advert
Results 1 - 2 of 2
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 266 - 268
1 Mar 2004
Mohanty SS Kay PR

A retrospective review of MRSA screening showed that of a total of 8911 patients screened pre-operatively between May 1996 and February 2001, 83 (0.9%) had MRSA isolated from one source or another. During the same period, 115 (13.6%) of 844 positive tissue samples taken during surgery grew Staphylococcus aureus. Of these only 1 (0.01%) was reported to be methicillin-resistant (MRSA). However, a total of 366 (43.4%) isolates from tissue samples were reported as coagulase-negative staphylococci (C-NS). Of these, 312 samples were tested for methicillin sensitivity, of which 172 (55.1%) were found to be resistant.

Staphylococcus epidermidis is the most prevalent and persistent species found on most skin and mucous membranes, constituting 65% to 90% of all staphylococci. Most isolates in tissue samples were found to be methicillin-resistant coagulase-negative staphylococcus (55.1%). Hence, it may be appropriate to undertake screening for methicillin-resistant Staphylococcus epidermidis in addition to that for MRSA.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 886 - 889
1 Sep 1999
Davis N Curry A Gambhir AK Panigrahi H Walker CRC Wilkins EGL Worsley MA Kay PR

All surgical operations have the potential for contamination, and the equipment used can harbour bacteria. We collected samples from 100 elective primary hip and knee arthroplasties. These showed rates of contamination of 11.4% for the sucker tips, 14.5% for light handles, 9.4% for skin blades and 3.2% for the inside blades used during surgery; 28.7% of gloves used for preparation were also contaminated. Of the samples taken from the collection bags used during hip arthroplasty, 20% grew bacteria, which represents a significant microbial reservoir. Also, 17% of theatre gowns were contaminated at the end of the operation. Contamination was found in 10% of the needles used during closure of the fascia. Overall, 76% of the organisms grown were coagulase-negative staphylococcus. A total of 63% of operations showed contamination in the field of operation. Some changes in practice are suggested. Follow-up for a minimum of two years revealed one deep infection but the organism was not identified as a contaminant. These data provide a baseline for studying the bacteriology of the surgery of revision arthroplasty.