header advert
Results 1 - 7 of 7
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 23 - 23
7 Aug 2023
Wehbe J Womersley A Jones S Afzal I Kader D Sochart D Asopa V
Full Access

Abstract

Introduction

30-day emergency readmission is an indicator of treatment related complication once discharged, resulting in readmission. A board-approved quality improvement pathway was introduced to reduce elective re-admissions.

Method

The pathway involved telephone and email contact details provision to patients for any non-life threatening medical assistance, allowing for initial nurse led management of all issues. A new clinic room available 7 days, and same day ultrasound scanning for DVT studies were introduced. A capability, opportunity and behavior model of change was implemented.

Readmission rates before and six months after implementation were collected from Model Hospital. A database used to document patient communications was interrogated for patient outcomes.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 57 - 57
1 Jul 2022
Peacock C Fu H Asopa V Clement N Kader D Sochart D
Full Access

Abstract

Introduction

The aims of our systematic review were to assess the Nickel sensitising potential of total knee arthroplasty (TKA), explore the relationship between Nickel hypersensitivity and clinical outcomes, and evaluate the utility of skin patch testing pre- and/or post-operatively.

Methodology

A literature search was performed through EMBASE, Medline and PubMed databases. Articles were screened independently by two investigators. Levels of Evidence were assessed using Oxford CEBM criteria and quality was assessed using MINORS and Cochrane risk-of-bias tools.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 74 - 74
1 Jul 2022
Phoon KM Afzal I Sochart D Gikas P Asopa V Kader D
Full Access

Abstract

Introduction

The NHS generates 4–5% of the nation's total carbon emissions and over 500,000 tonnes of waste annually. Up to one-third of waste from orthopaedic procedures are recyclable, with large joint arthroplasties producing more than other subspecialties. However, there is limited evidence demonstrating the principles of sustainability and its benefits within orthopaedic surgery. This study aimed to analyse the environmental impact and sustainable initiatives undertaken within orthopaedic surgery.

Methodology

A systematic review was performed according to PRISMA guidelines. The systematic search was conducted through EMBASE, Medline, and PubMed libraries.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 42 - 42
1 Jul 2022
Fu H Afzal I Asopa V Kader D Sochart D
Full Access

Abstract

Background

There is a trend towards minimising length of stay (LOS) after total knee arthroplasty (TKA), as longer LOS is associated with poorer outcomes and higher costs. Patient factors known to influence LOS after TKA include age and ASA grade.

Evidence regarding body mass index (BMI) in particular is conflicting. Some studies find that increased BMI predicts greater LOS, while others find no such relationship. Previous studies have generally not examined socioeconomic status, which may be a confounder. They have generally been conducted outside the UK, and prior to the Covid-19 pandemic.

Methods

We conducted a retrospective cohort study of 1031 primary TKAs performed 01-04-2021 to 31-12-2021, after resumption of elective surgery in our centre. A multivariate regression analysis was performed using a Poisson model over pre-operative variables (BMI, age, gender, ASA grade, index of multiple deprivation, and living arrangement) and peri-operative variables (AM/PM operation, operation side, duration, and day of the week).


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 38 - 38
1 Jul 2022
Fu H Peacock C Wang C Kader D Clement N Asopa V Sochart D
Full Access

Abstract

Aim

End-stage arthropathy is a well-known complication of haemophilia, with recurrent haemarthroses leading to joint destruction, deformity, pain, and stiffness. In the knee, this is often treated with total knee arthroplasty (TKA), which can be more challenging in patients with haemophilia (PwH) and associated with poorer outcomes. We conducted a systematic literature review and meta-analysis to determine implant survivorship, functional outcomes and complication rates.

Method

A systematic review was conducted using MEDLINE, EMBASE, and PubMed for studies reporting TKA outcomes with Kaplan-Meier survivorship in PwH (PROSPERO registered). Meta-analysis was performed for survivorship and outcomes, and the results were compared to outcomes from the National Joint Registry (NJR).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 79 - 79
1 Jul 2012
Kazi Z Cooney A Caplan N Newby M Gibson ASC Kader D
Full Access

Statement of purpose

To determine whether the Q-angle, measured in a defined and reproducible manner, correlates with the TT-TG distance in patients with patellar instability.

Methods and results

The Q-angle represents the angle between the vector of action of the quadriceps and patellar tendon. The normal angle is 14+/−3° in males and 17+/−3° in females. An increased Q-angle is associated with an increased risk of patellar instability, although there is disagreement on its reliability and validity. It can be affected by the anatomical points used to record the measurement, the position of the limb and whether the quadriceps are relaxed or contracted. TT-TG is ascertained by axial CT scanning, with a value exceeding 20mm associated with patellar instability.

Q-angles were measured in patients presenting to the patella clinic who had previously undergone Lyon protocol CT scanning for patellar instability. Patients were positioned supine with both feet in neutral rotation taped to a specially designed wooden board (the same position used for CT scanning). The anatomical landmarks were the anterior superior iliac spine, the centre of the patella and the centre of the tibial tuberosity. Both knees were measured with the quadriceps relaxed (relaxed Q-angle) and contracted (contracted Q-angle).

Thirty-four knees were measured, 24 pathological and 10 non-pathological. Pearson moment correlation demonstrated a significant correlation between relaxed Q-angle and TT-TG in all knees (R=-0.377; p=0.028). In pathological knees, contracted Q-angle also demonstrated a significant correlation with TT-TG but to a lesser extent than relaxed Q-angle (R=-0.428; p=0.037, R=-0.578; p=0.003 respectively). Linear regression analysis demonstrated relaxed Q-angle as a significant predictor of TT-TG distance in pathological knees. Contracted Q-angle was not significant.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 61 - 61
1 Jul 2012
Chambers S Jones M Michla Y Kader D
Full Access

The purpose of this study was to determine the accuracy of MRI scan for the detection of meniscal pathology in our unit. There are published data which show that both sensitivity and specificity can approach 90% when compared to arthroscopic findings.

We retrospectively analysed a single surgeon series of 240 scopes for all indications The arthroscopic reports included an outline diagram of the meniscus upon which the surgeon recorded operative findings. 112 of these patients had also had recent MRI.

We looked at whether the MRI report showed a tear, and this was graded Y/N. The arthroscopic report was graded for tear: Y/N. 66 patients had a positive scan. 64 of these were found to have a tear at surgery. 37 scans were reported as “no tear”, of which 4 were found to have a tear at surgery. Nine scans were not easy to classify as they were descriptive.

In our series of 112 knees, MRI was 90.5% sensitive, 89.5% specific and 90.1% accurate.

When a definite diagnosis of “tear”, or “no tear” was made at scan, there were two false positives and four false negatives. False positives may be unnecessarily exposed to the risks of surgery. Patients with negative scans had a mean delay to surgery of 33 weeks compared to 18 weeks for patients with positive scans. False negatives may wait longer for their surgery. Two of the false negative scans clearly showed meniscus tears which were missed by the reporting radiographer. In our series the scan itself was more accurate than the reporting. It is important to have an experienced musculoskeletal radiologist to minimise the number of missed tears. It is also important for surgeon to check the scan as well as the report.