header advert
Results 1 - 6 of 6
Results per page:
Bone & Joint Open
Vol. 4, Issue 11 | Pages 889 - 898
23 Nov 2023
Clement ND Fraser E Gilmour A Doonan J MacLean A Jones BG Blyth MJG

Aims

To perform an incremental cost-utility analysis and assess the impact of differential costs and case volume on the cost-effectiveness of robotic arm-assisted unicompartmental knee arthroplasty (rUKA) compared to manual (mUKA).

Methods

This was a five-year follow-up study of patients who were randomized to rUKA (n = 64) or mUKA (n = 65). Patients completed the EuroQol five-dimension questionnaire (EQ-5D) preoperatively, and at three months and one, two, and five years postoperatively, which was used to calculate quality-adjusted life years (QALYs) gained. Costs for the primary and additional surgery and healthcare costs were calculated.


Aims

The aim of this study was to compare any differences in the primary outcome (biphasic flexion knee moment during gait) of robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) at one year post-surgery.

Methods

A total of 76 patients (34 bi-UKA and 42 TKA patients) were analyzed in a prospective, single-centre, randomized controlled trial. Flat ground shod gait analysis was performed preoperatively and one year postoperatively. Knee flexion moment was calculated from motion capture markers and force plates. The same setup determined proprioception outcomes during a joint position sense test and one-leg standing. Surgery allocation, surgeon, and secondary outcomes were analyzed for prediction of the primary outcome from a binary regression model.


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1561 - 1570
1 Oct 2021
Blyth MJG Banger MS Doonan J Jones BG MacLean AD Rowe PJ

Aims

The aim of this study was to compare the clinical outcomes of robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) during the first six weeks and at one year postoperatively.

Methods

A per protocol analysis of 76 patients, 43 of whom underwent TKA and 34 of whom underwent bi-UKA, was performed from a prospective, single-centre, randomized controlled trial. Diaries kept by the patients recorded pain, function, and the use of analgesics daily throughout the first week and weekly between the second and sixth weeks. Patient-reported outcome measures (PROMs) were compared preoperatively, and at three months and one year postoperatively. Data were also compared longitudinally and a subgroup analysis was conducted, stratified by preoperative PROM status.


The Bone & Joint Journal
Vol. 102-B, Issue 11 | Pages 1511 - 1518
1 Nov 2020
Banger MS Johnston WD Razii N Doonan J Rowe PJ Jones BG MacLean AD Blyth MJG

Aims

The aim of this study was to compare robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) in order to determine the changes in the anatomy of the knee and alignment of the lower limb following surgery.

Methods

An analysis of 38 patients who underwent TKA and 32 who underwent bi-UKA was performed as a secondary study from a prospective, single-centre, randomized controlled trial. CT imaging was used to measure coronal, sagittal, and axial alignment of the knee preoperatively and at three months postoperatively to determine changes in anatomy that had occurred as a result of the surgery. The hip-knee-ankle angle (HKAA) was also measured to identify any differences between the two groups.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_3 | Pages 11 - 11
1 Feb 2020
Johnston WD Razii N Banger MS Rowe PJ Jones BG MacLean AD Blyth MJG
Full Access

The objective of this study was to compare differences in alignment following robotic arm-assisted bi-unicompartmental knee arthroplasty (Bi-UKA) and conventional total knee arthroplasty (TKA).

This was a prospective, randomised controlled trial of 70 patients. 39 TKAs were implanted manually, as per standard protocol at our institution, and 31 Bi-UKA patients simultaneously received fixed-bearing medial and lateral UKAs, implanted using robotic arm-assistance. Preoperative and 3-month postoperative CT scans were analysed to determine hip knee ankle angle (HKAA), medial distal femoral angle (MDFA), and medial proximal tibial angle (MPTA). Analysis was repeated for 10 patients by a second rater to validate measurement reliability by calculating the intra-class correlation coefficient (ICC).

Mean change in HKAA towards neutral was 2.7° in TKA patients and 2.3° in Bi-UKA patients (P=0.6). Mean change in MDFA was 2.5° for TKA and 1.0° for Bi-UKA (P<0.01). Mean change in MPTA was 3.7° for TKA and 0.8° for Bi-UKA (P<0.01). Mean postoperative MDFA and MPTA for TKAs were 89.8° and 89.6° respectively, indicating orientation of femoral and tibial components perpendicular to the mechanical axis. Mean postoperative MDFA and MPTA for Bi-UKAs were 91.0° and 86.9° respectively, indicating a more oblique joint line orientation. Inter-rater agreement was excellent (ICC>0.99). Early functional activities, according to the new Knee Society Scoring System, favoured Bi-UKAs (P<0.05).

Robotic arm-assisted, cruciate-sparing Bi-UKA better maintains the natural anatomy of the knee in the coronal plane and may therefore preserve normal joint kinematics, compared to a mechanically aligned TKA. This has been achieved without significantly altering overall HKAA.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1495 - 1497
1 Nov 2007
Jones BG Mehin R Young D

Intramedullary tibial nailing was performed in ten paired cadavers and the insertion of a medial-to-lateral proximal oblique locking screw was simulated in each specimen. Anatomical dissection was undertaken to determine the relationship of the common peroneal nerve to the cross-screw.

The common peroneal nerve was contacted directly in four tibiae and the cross-screw was a mean of 2.6 mm (1.0 to 10.7) away from the nerve in the remaining 16. Iatrogenic injury to the common peroneal nerve by medial-to-lateral proximal oblique locking screws is therefore a significant risk during tibial nailing.