Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 11 - 11
1 Nov 2018
Foong B Jani P
Full Access

There is an inherent risk of iatrogenic new neurological deficit (NND) arising at the spinal cord, cauda equina and nerve root during spinal surgery. Intraoperative neurophysiological monitoring (IONM) can be employed to preserve spinal cord function during spinal surgery. IONM techniques include somatosensory and motor evoked potentials, amongst others. A Canadian survey of 95 spinal surgeons showed that 62.1% used IONM and a similar survey in France of 117 spinal surgeons showed that only 36% used IONM. Unavailability was a common reason for its disuse. Current literature by the British Society of Clinical Neurophysiology has outlined the importance of IONM in preventing NND and the need for the implementation of guidelines for IONM. The lack of an established guideline has resulted in a varied approach in the use of IONM in England. There has been no previous attempt to ascertain the current use of IONM in England. Our study is aimed at assessing the variability of the use of IONM in England as well as identifying the rationale amongst surgeons that dictate their use of IONM. We are in the process of investigating the indications of use of IONM for cervical and lumbar spine procedures in 252 spinal surgeons from 33 hospitals with spinal services. Our survey will illustrate the current use of IONM in spinal surgery in England. It will highlight some of the reasons for the variability of use of IONM and identify factors that can contribute to a more standardised use of IONM in spinal surgery.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVI | Pages 10 - 10
1 Apr 2012
Kumar V Jani P Bagga T
Full Access

We conducted a retrospective study to compare the blood loss following Primary Total Knee Replacement (TKR) to see effectiveness of Tranexamic acid (TXA).v/s Cell Salvage.

This was a retrospective study conducted from Aug 2008 to Dec 2009. We compared two groups. Group A was given TXA IV (two doses – first dose before tourniquet release and second dose six hours post-operative) and in group B post op cell salvage was used. 84 knees were included in this study with 42 patients in each group. The surgical technique, implants used and post-operative Thromboprophylaxis care were same in both groups.

The corrected mean Hob drop in Group A was 1.76g/dl (Range-0.7 to 4.3) while that in Group B was 2.32g/dl (Range-0.7 to 5.3). Use of TXA lead to a 24.13% decrease in mean Hob drop and 3.7% fall in mean drain output following TKR in our study. Two thromboembolic events in the form of deep vein thrombosis (DVT) confirmed by Duplex US scan, were noted in each group. There was no difference in complication rate i.e. drain site infection and wound leaking in either group. Costs - The cost of two doses of TXA is £3.81 per patient and cost of bellovac drain was £85 per patient.

We found TXA was more effective and cheaper than autolougus blood transfusion and there was no increase in thromboembolic complications