header advert
Results 1 - 1 of 1
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 18 - 18
1 Feb 2020
Rivière C Jain A Harman C Maillot C Parsons T
Full Access

Introduction

The alternative kinematic alignment (KA) technique for total knee arthroplasty (TKA) aims at restoring the native joint line orientation and laxity of the knee. The goal is to generate a more physiological prosthetic knee enabling higher functional performance and satisfaction for the patient. KA TKA have only been reported so far with cruciate retaining and posterior-stabilised designs. Similarly, medial pivot design for TKA has been recently developed to enable more natural knee kinematics and antero-posterior stability. The superiority of KA technique and medial pivot implant design is still controversial when compared to current practice. Our study aims to assess the value of KA TKA when performed with medial pivot implants.

Methods

We conducted a retrospectively matched case-control study. Clinical data was prospectively collected on patients as part of an ongoing ODEP study. Thirty-three non-selected consecutive KA TKAs performed by the lead author were matched to a control group of 33 measured resection with mechanically aligned (MA) TKAs performed by other consultant surgeons. Patients were matched for sex, age, BMI and pre-operative Oxford Knee Score (OKS). Pre-operative median OKS was 21 points (max 48), mean age was 69, mean BMI 31, and there were 21 female patients in both arms. The medial pivot GMK Sphere implant (Medacta, Switzerland) was used in all cases. OKS and EQ-5D scores were measured pre-operatively and at 1-year post-op. Patient outcome satisfaction scores were assessed at 1-year follow-up using a visual analogic scale (VAS). Pre- and post-operative knee radiographs were analysed using TraumaCad software.