header advert
Results 1 - 6 of 6
Results per page:
Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 85 - 85
1 Dec 2015
Salin T Pakarinen H Noponen N Lantto I Hyvönen P
Full Access

Osteomyelitis is an infectious process in bone occasionally leading to bone destruction. Traditionally a two-stage operation is performed using PMMA + antibiotic beads or a spacer. In the second operation the void filler is removed and the defect is filled with autologous bone.

Bioactive glass (BAG) S53P4 is an antibacterial biodegradable bone substitute. This feature is based on an increase in pH and the osmotic pressure around the BAG, a phenomenon which has been shown to kill both planktonic bacteria and bacteria in biofilm in-vitro.

We analyzed retrospectively our early results of osteomyelitis patients treated with BAG from the patient's clinical history

The diagnosis was stated in addition to bacterial samples by MRI, CT and plain radiographs or by a combination of these. Between 2007–2013 we applied BAG as a void-filler in 20 cases (15 male and 5 female) of osteomyelitis in the lower (19) or the upper (1) limb in one-stage procedure. The patients had been suffering from symptoms of osteomyelitis a mean 3,5 months (0,25–24,00) and had a history of mean 3,5 (1–11) earlier operations.

Osteomyelitis was estimated to be healed when the enclosed systemic antibiotic treatment and clinical controls were carried out and the patient didn't have symptoms of a persisting disease.

The average postoperative follow up was 7,8 (3,0–59,0) months. Fifteen (75%) of the patients healed. One patient run out of controls, but was symptom free during his last visit. In four cases we had to remove the bioactive glass because of continuous secretion. In three cases the debridement was incomplete and one had a poor soft tissue cover and a candida infection. Adjuvant systemic antibiotic treatment was prescribed postoperatively 7,3 (4–19) weeks.

Bioactive glass is an effective void filling material in the treatment of osteomyelitis. Proper debridement and a soft tissue cover should be performed.

Main reason for that the five patients did not heal is, that this procedure is new and we were looking for the right indications and techniques.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 464 - 464
1 Sep 2012
Lindfors N Hyvönen P Nyyssönen M Kirjavainen M Kankare J Gullichsen E Salo J Lindfors N
Full Access

Bioactive glasses (BAGs) are bone substitutes with bone bonding, angiogenesis promoting and antibacterial properties. The bioactive process leading to bone bonding has been described as a sequence of reactions in the glass and at its surface. Implantation of the glass is followed by a rapid exchange of Na+ in the glass with H+ and H3O+ from the surrounding tissue, leading to the formation of silanol (SiOH) groups at the glass surface. Due to migration of Ca2+ and PO43− groups to the surface and cystallization, a CaO-P2O5 hydroxyapatite (HA) layer is formed on top of the Si-rich layer. Finally, cell interactions with the HA layer subsequently initiate the bone forming pathway.

The rapid increase in pH and the subsequent osmotic effect caused by dissolution of the glass have been suggested to partly explain the antibacterial properties observed for BAGs. Comparing bactericidal effects of different BAGs, BAG-S53P4 has been shown to be the most effective, with the fastest killing or growth inhibitory effect. This antibacterial effect has been observed in vitro for all pathogens tested, including the most important aerobic and anaerobic pathogens, as well as very resistant bacteria.

In a multicentre study in 2007–2009, BAG-S53P4 was used as bone graft substitute in treatment of osteomyelitis. Eleven patients (nine males, two females) with a radiologically diagnosed osteomyelitis in the lower extremity (N=10) and in the spine (N-1) participated.

In the operation, the infected bone and the soft tissue were removed, and the cavitary bone defects were filled with BAG-S53P4 (BonAlive™, Bonalive Biomaterials Ltd., Finland). In four patients, muscle flaps were used as part of the treatment. Eight patients were treated in a one-stage procedure. Kanamycin granules were used in one patient and Garamycin granules (Septocol ®) in two patients.

Patient data were obtained from hospital patient' records until August 2010, resulting in a mean follow-up period of 29 months (range 15–43).

BAG-S53P4 was well tolerated; no BAG-related adverse effects were seen in any patient. The use of BAG-S53P4 as a bone graft substitute resulted in a fast recovery. Long-term clinical outcome was good or excellent in ten of eleven patients.

These primary results indicate that BAG-S53P4 can be considered as a good and usable material in treatment of osteomyelitis. After this study BAG-S53P4 has been used in several other patients with very promising results.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 805 - 810
1 Jun 2012
Flinkkilä T Kaisto T Sirniö K Hyvönen P Leppilahti J

We assessed the short- to mid-term survival of metallic press-fit radial head prostheses in patients with radial head fractures and acute traumatic instability of the elbow.

The medical records of 42 patients (16 males, 26 females) with a mean age of 56 years (23 to 85) with acute unstable elbow injuries, including a fracture of the radial head requiring metallic replacement of the radial head, were reviewed retrospectively. Survival of the prosthesis was assessed from the radiographs of 37 patients after a mean follow-up of 50 months (12 to 107). The functional results of 31 patients were assessed using range-of-movement, Mayo elbow performance score (MEPS), Disabilities of the Arm, Shoulder and Hand (DASH) score and the RAND 36-item health survey.

At the most recent follow-up 25 prostheses were still well fixed, nine had been removed because of loosening, and three remained implanted but were loose. The mean time from implantation to loosening was 11 months (2 to 24). Radiolucent lines that developed around the prosthesis before removal were mild in three patients, moderate in one and severe in five. Range of movement parameters and mass grip strength were significantly lower in the affected elbow than in the unaffected side. The mean MEPS score was 86 (40 to 100) and the mean DASH score was 23 (0 to 81). According to RAND-36 scores, patients had more pain and lower physical function scores than normal population values.

Loosening of press-fit radial head prostheses is common, occurs early, often leads to severe osteolysis of the proximal radius, and commonly requires removal of the prosthesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 265 - 272
1 Feb 2007
Ristiniemi J Flinkkilä T Hyvönen P Lakovaara M Pakarinen H Jalovaara P

External fixation of distal tibial fractures is often associated with delayed union. We have investigated whether union can be enhanced by using recombinant bone morphogenetic protein-7 (rhBMP-7).

Osteoinduction with rhBMP-7 and bovine collagen was used in 20 patients with distal tibial fractures which had been treated by external fixation (BMP group). Healing of the fracture was compared with that of 20 matched patients in whom treatment was similar except that rhBMP-7 was not used.

Significantly more fractures had healed by 16 (p = 0.039) and 20 weeks (p = 0.022) in the BMP group compared with the matched group. The mean time to union (p = 0.002), the duration of absence from work (p = 0.018) and the time for which external fixation was required (p = 0.037) were significantly shorter in the BMP group than in the matched group. Secondary intervention due to delayed healing was required in two patients in the BMP group and seven in the matched group.

RhBMP-7 can enhance the union of distal tibial fractures treated by external fixation.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages 299 - 305
1 Mar 2003
Hyvönen P Melkko J Lehto VP Jalovaara P

Our aim was to evaluate bursal involvement at different stages of the impingement syndrome as judged by conventional histopathological examination and expression of tenascin-C, which is known to reflect active reparative processes in different tissues and disorders.

Samples of subacromial bursa were taken from 33 patients with tendinitis, 11 with a partial tear and 18 with a complete tear of the rotator cuff, and from 24 control shoulders. We assessed the expression of tenascin-C, the thickness of the bursa, and the occurrence and degree of fibrosis, vascularity, haemorrhage and inflammatory cells.

The expression of tenascin-C was significantly more pronounced in the complete tear group (p < 0.001) than in the partial tear, tendinitis or control groups. It was more pronounced in the tendinitis group than in the control group (p = 0.06), and there was more fibrosis in all the study groups than in the control group. The changes in the other parameters were not equally distinctive. Expression of tenascin-C did not correlate with the conventional histopathological parameters, suggesting that these markers reflect different phases of the bursal reaction.

Tenascin-C seems to be a general indicator of bursal reaction, being especially pronounced at the more advanced stages of impingement and this reaction seems to be an essential part of the pathology of impingement at all its stages.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 5 | Pages 813 - 816
1 Sep 1998
Hyvönen P Lohi S Jalovaara P

We performed open acromioplasty for intractable impingement syndrome on 96 shoulders (93 patients) with an intact rotator cuff. All the shoulders were examined by ultrasound after a mean interval of nine years. Those showing pathological findings, a poor or fair subjective result, or deterioration of the primary excellent outcome had MRI and/or arthrography.

The mean Constant score for the affected shoulders was 70 points and that for 48 non-involved, symptom-free shoulders, 84 points. The subjective outcome was excellent in 45, good in 24, fair in 18 and poor in 9 shoulders. Complete tears were found in 12 shoulders and partial tears in seven. A total of 14 shoulders was symptom-free after acromioplasty, but after an average of five years became painful again and showed deterioration. Of these, six had complete tears and four partial tears of the cuff. The tear rate was 4% in shoulders initially judged to be excellent, 25% in good, 33% in fair and 55% in poor shoulders. The tear rate was 71% in shoulders which subsequently deteriorated. The incidence was higher in men (25%) than in women (11%).

We conclude that a tear of the rotator cuff may appear after acromioplasty, although there was no evidence of a tear at the time of operation. This is usually the reason for deterioration in a shoulder with an initially good operative outcome.