header advert
Results 1 - 20 of 45
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 21 - 21
7 Jun 2023
Nandra R Fishley W Whitehouse S Carluke I Kramer D Partington P Reed M Evans J Panteli M Charity J Wilson M Howell J Hubble M Petheram T Kassam A
Full Access

In metal-on-metal (MoM) hip replacements or resurfacings, mechanical induced corrosion can lead to a local inflammatory response, pseudo tumours and elevated serum metal ions, requiring revision surgery.

The size and diametral clearance of Anatomic (ADM) and Modular (MDM) Dual Mobility bearings matches that of certain MOM components. Presenting the opportunity for revision with exchange of the metal head for ADM/MDM bearings without removal of the acetabular component if it is well-fixed and appropriately positioned.

Between 2012 and 2020, across two centres, 94 patients underwent revision of a MoM hip replacement or resurfacing. The mean age was 65.5 (33–87) years. In 53 patients (56.4%), the acetabular component was retained, and dual mobility bearings were used (DM); in 41 (43.6%) the acetabulum was revised (AR). DM was only considered where the acetabular component was satisfactorily positioned and well-integrated into bone, with no surface damage. Patients underwent clinical and radiographic follow-up to at least one-year (mean 42.4 (12–96) months).

One (1.1%) patient died before one-year, for reasons unrelated to the surgery. In the DM group, two (3.8%) patients underwent further surgery; one (1.9%) for dislocation and one (1.9%) for infection. In the AR group, four (12.2%) underwent further procedures; two (4.9%) for loosening of the acetabular component and two (4.9%) following dislocations. There were no other dislocations in either group. In the DM group, operative time (68.4 v 101.5 mins, p<0.001), postoperative drop in haemoglobin (16.6 v 27.8 g/L, p<0.001), and length of stay (1.8 v 2.4 days, p<0.001) were significantly lower. There was a significant reduction in serum metal ions postoperatively in both groups (p<0.001 both Cobalt and Chromium) although there was no difference between groups for this reduction (p=0.674 Cobalt; p=0.186 Chromium).

In selected patients with MoM hip arthroplasty, where the acetabular component is well-fixed, in a satisfactory position and there is no surface damage, the metal head can be exchanged for ADM/MDM bearings with retention of the acetabular prosthesis. Presenting significant benefits through a less invasive procedure, and a low risk of complications, including dislocation.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 23 - 23
7 Jun 2023
Coveney E Hutton C Patel N Whitehouse S Howell J Wilson M Hubble M Kassam A
Full Access

Venous thromboembolism (VTE) is a preventable cause of morbidity and mortality in patients undergoing elective hip arthroplasty surgery. The balance of post-operative VTE prophylaxis and risk of post-operative haemorrhage remains at the forefront of surgeon's mind. The National Institute for Clinical Excellence (NICE) has altered their prophylaxis guidance in the setting of total hip arthroplasty (THA). The aim of this study was to present the VTE incidence in 8,890 patients who underwent total hip arthroplasty between January 1997 and March 2018 with Aspirin as the primary agent for pharmacological thromboprophylaxis.

Analysis of prospective data collection from consecutive patients undergoing THA was performed with the incidence of deep vein thrombosis (DVT) and pulmonary embolism (PE) occurring within 6 months of the index operation as the primary outcome measure. 90-day all-cause mortality of this cohort of patients was also analysed.

8890 patients were reviewed. This included 7235 primary, 224 complex primary and 1431 revision cases. The incidence of DVT was 0.64% after elective THA and the incidence of PE was 0.54%. There was no difference in the incidence between primary and revision cases. The 90-day all-cause mortality was 0.88%. Cardiovascular and respiratory disease were the main causes of death following surgery. Only 0.03% of deaths (n= 3) within 90 days of index surgery were due to VTE.

Our results support the use of aspirin as an effective form of prophylaxis against VTE following THA. It is not associated with an increased incidence in symptomatic DVT, PE or death compared to other published studies. The fact that it is inexpensive, readily available, requires no monitoring and does not pose an increased risk of bleeding are other attractive advantages of using aspirin for VTE prophylaxis.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 34 - 34
1 Apr 2022
Gowda S Whitehouse S Morton R Panteli M Charity J Wilson M Timperley J Hubble M Howell J Kassam A
Full Access

The MAKO Robotic arm is a haptic robotic system that can be used to optimise performance during total hip arthroplasty (THA). We present the outcome of the first 40 robotic cases performed in an NHS foundation trust along with the technique of performing robotic THA in our unit.

Forty consecutive patients undergoing robotic THA (rTHA) were compared to a case matched group of patients undergoing manual THA (m-THA). 2:1 blinded case matching was performed for age, sex, implants used (Trident uncemented socket and cemented Exeter stem, Stryker Mahwah, NJ, US) and surgeon grade. Comparisons were made for radiological positioning of implants, including leg length assessment, and patient reported functional outcome (PROMS). Pre- and post-operative radiographs were independently analysed by 2 authors.

All patients underwent THA for a primary diagnosis of osteoarthritis. No significant difference between groups was identified for post-operative leg length discrepancy (LLD) although pre-operatively a significantly higher LLD was highlighted on the MAKO group, likely due to patient selection. Significantly lower post-operative socket version was identified in the MAKO cohort although no difference in post-operative cup inclination was noted. However, there was significantly larger variance in post-op LLD (p=0.024), cup version (p=0.004) and inclination (p=0.05) between groups indicating r-THA was significantly less variable (Levene's test for homogeneity of variance). There was no significant difference in the number of cases outside of Lewinnek's ‘safe’ zone for inclination (p=0.469), however, there were significantly more cases outside Lewinnek's ‘safe’ zone for version (12.5% vs 40.3%, p=0.002) in the m-THA group.

We report the commencement of performance of MAKO robotic THA in an NHS institution. No problems with surgery were reported during our learning curve. Robotic THA cases had less variability in terms of implant positioning suggesting that the MAKO robot allows more accurate, less variable implant positioning with fewer outliers. Longer term follow-up of more cases is needed to identify whether this improved implant positioning has an effect on outcomes, but the initial results seem promising.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 25 - 25
1 Apr 2022
Evans J Salar O Whitehouse S Kassam A Howell J Wilson M Timperley J Sayers A Whitehouse M Wilton T Hubble M
Full Access

The Exeter V40 femoral stem is the most implanted stem in the NJR for primary THA. In 2004, the 44/00/125 stem was released for use in “cement-in-cement” revision cases. It has however been used ‘off-label’ as a primary stem when, for example, patient anatomy requires a smaller stem with a 44mm offset. We aimed to investigate survival of this stem in comparison to others in the range when used in primary THAs recorded in the NJR.

Analyses were performed using a dataset based on that used for the 2020 NJR annual report. Our exposure was the stem; the outcome was all-cause construct revision. Crude analyses were performed using Kaplan-Meier and adjusted using Cox models. The 44/00/125 stem was directly compared to other stems in the Exeter range.

We analysed 330,732 primary THAs using the Exeter V40 stem comprising 34.5% of the 958,869 THAs with complete information from the start of the NJR to 31 December 2018. The 44/00/125 stem was implanted in 2,158 primary THAs with 67.5% in female patients and a mean age of 67.8. The 10-year revision estimate for the 44/00/125 stem was 4.9% (95%CI 3.6, 6.8) and in constructs using an Exeter V40 stem was 2.8% (95%CI 2.7, 2.8). Controlling for age, sex and ASA demonstrated an increased overall hazard of revision for constructs using the 44/00/125 stem compared to constructs using other Exeter V40 femoral stems (HR 1.8 (95%CI 1.4, 2.3)).

Although the revision estimate is within the NICE 10-year benchmark, survivorship of constructs using the 44/00/125 stem appears to be lower than the rest of the Exeter V40 range. Attempts to control for age, sex and ASA will not take into account confounding by indication i.e. patients with more complex anatomy who may have a higher risk of revision. Surgeons and patients should be reassured by this but should be aware of the observed increased revision estimate and use the stem according to its indications.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 29 - 29
1 Aug 2021
Fishley W Selvaratnam V Carluke I Partington P Reed M Kramer D Wilson M Hubble M Howell J Timperley A Whitehouse S Kassam A Petheram T
Full Access

Femoral cement-in-cement revision is a well described technique to reduce morbidity and complications in hip revision surgery. Traditional techniques for septic revision necessitate removal of all bone cement from the femur. In our two institutions, we have been using a cement-in-cement technique, leaving the distal femoral cement in selected cases for septic hip revision surgery.

Between February 2010 and September 2019, 89 patients with prosthetic hip infection underwent first or single stage procedures leaving the distal femoral cement in situ and performing a cement-in-cement revision. The mean patient age was 72.0 years (24–92). The median time from the last arthroplasty procedure was 29.0 months (1–294).

81 patients underwent revision using a cemented Exeter stem, 7 patients received an articulating spacer, and one patient underwent excision arthroplasty with the distal cement left in situ. Patients received clinical and radiographic follow-up with a mean of 42.8 months (range 11.0–120.1 months). Oxford hip scores were collected from each institution's existing databases.

9 patients (10.1%) died within one year of surgery. No deaths were directly related to joint infection or the surgery. One patient was lost to follow up before one year.

Of the remainder, 7 patients (8.9%) required further procedures for infection and were therefore considered to be treatment failures. 6 patients (7.6%) underwent planned second stage procedures with no recurrence of infection. 7 patients (8.9%) had further surgery for non-infective reasons. The Kaplan-Meier estimate of infection free survival at one year was 93.7% (95% CI 88.4 to 99.0%).

No patients underwent revision for stem loosening. Oxford hip scores were available at over one year postoperatively for 51 patients with a mean score of 30.6, and a mean gain of 11.9.

In our combined cohort of patients, cement-in-cement revision had an infection eradication rate of 91.1%. Patient selection is crucial, and the procedure can only be performed when there is a well-fixed cement mantle. However, when strict criteria are followed, this technique offers potential significant benefits to surgeons performing this challenging surgery, and more importantly the patients undergoing them.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_6 | Pages 22 - 22
1 May 2019
Takada R Whitehouse S Hubble M Wilson M Howell J Timperley A Kassam A
Full Access

Introduction

Varus alignment of the femoral component in total hip arthroplasty (THA) is thought to be a risk factor for implant loosening and early revision surgery. The purpose of this study was to evaluate whether the Exeter stem tolerates varus alignment and assess if this theoretical malalignment has an influence on clinical outcomes.

Methods

A total of 4126 consecutive THAs were reviewed for patients between 2006 and 2012 to allow for a minimum five-year follow-up. To determine the effects of the stem alignment on results, the hips were classified into 3 groups on the basis of stem alignment in initial postoperative anteroposterior radiographs. The alignment of the stem was defined as neutral, valgus (≥ 3° of lateral deviation), or varus (≥ 3° of medial deviation). The primary outcome was all cause revision with patient related outcomes assessed with Oxford hip score pre and post-operatively.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_6 | Pages 24 - 24
1 May 2019
Kassam A Whitehouse S Wilson M Hubble M Timperley A Howell J
Full Access

Introduction

Rationing of orthopaedic services is increasingly being used by Care Commissioning Groups (CCG) within the United Kingdom to restrict the numbers of patients being referred for Total Hip Arthroplasty (THA). In Devon, only patients with an Oxford Hip Score (OHS) less than 20 are referred on for specialist Orthopaedic Review. The aim of this study was to look at long term outcomes after THA to see if this rationing has any rational base to justify its use

Methods

Consecutive patients undergoing THA in Exeter between 1996 and 2012 had OHS' collected prospectively pre-operatively and a minimum of 4 years post-operatively. These scores were analysed looking for trends in patient related outcome scores.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 34 - 34
1 May 2018
Woodbridge A Wilson M Whitehouse S Hubble M
Full Access

Cement-in-cement femoral revision is a proven technique in revision total hip arthroplasty, with excellent results when using standard sized Exeter stems. The Exeter 44/00 125 mm short revision stem was introduced in 2004 to facilitate cement-in-cement revision. The stem is 25mm shorter and has a slimmer body to allow greater flexibility to adjust depth of insertion and version of the stem. However, it is not known if this change in stem length and size effects its longer term performance. We therefore reviewed the clinical outcome and survival of the Exeter 44/00 short stem used for cement-in-cement revision in our unit, with a minimum of 5 years follow up.

166 cases were performed between 2004 and 2010. 103 hips were available for 5 year clinical and radiological follow up, with 91 hips surviving to final review in 2017. At 5 years, 43 hips had died, 13 were revised and 7 were too frail to attend clinical review. The fate of all 166 hips were known and included in the survival analysis.

Median clinical scores improved significantly. Sixteen hips required re-revision (infection 6, loose cup 3, periprosthetic fracture 3, instability 2, stem fracture with chronic infection 1 and pain 1). Kaplan-meier survival analysis revealed 100% survival for aseptic loosening, 96.8% survival for stem failure and 88.9% survival for all causes.

This is the largest series with the longest follow up of the Exeter 44/00 short revision stem. The stem performs equally well as standard Exeter stems with regards to aseptic loosening. The single stem fracture occurred secondary to bone loss in chronic infection, highlighting the importance of providing adequate proximal support for the stem. Periprosthetic fracture occurred in 2.4% of this series of revision cases.

Larger registry-based studies may provide additional information on the performance of this stem.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 31 - 31
1 Jun 2017
Swanton E Hubble M
Full Access

Although cement in cement acetabular revision is a recognised option in the presence of a well-fixed cement mantle, partial cement mantle retention is not normally recommended or practiced. However, when revising a cemented acetabular cup it is not infrequent to be faced with loose superolateral cement but well-fixed medial cement. Removal of the well-fixed cement can be time consuming and destructive. An alternative would be to retain this cement and incorporate it into the reconstruction. This study assesses the practice and results of partial cement mantle retention (PCR) at acetabular revision.

We retrospectively identified a cohort of 28 hips in 26 patients using the PCR technique from 1st January 2000 to 1st January 2013. This represented 3.3% of cup revisions where a cemented cup was used.

The area of cement loss was reconstructed in one of three ways: re-cementing into drill holes (6 cases); impaction grafting of the defect (8 cases); or use of a trabecular metal wedge (14 cases).

24 hips had a minimum 2-year follow up (mean 6 years).

There were no subsequent revisions for aseptic loosening.

One acetabulum was later revised for dislocation and X-rays were lost in one patient leaving 22 patients with x-ray available and retained implants. Two of these cases showed progression of lucent lines, which were not clinically significant.

Retaining well-fixed medial cement during socket revision appears to be a reasonable reconstruction option in carefully selected cases.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 31 - 31
1 Jun 2016
Westerman R Whitehouse S Howell J Hubble M Timperley A Wilson M
Full Access

Introduction

The Exeter Hip femoral component remains largely unchanged from the original design, introduced in 1970. It is a highly polished, modular, double tapered stem and has undergone various minor modifications to surface, modularity and most recently the taper; changed to the current V40TM design in 2000.

The effect of any design modification cannot easily be foreseen and greater emphasis is now placed on ensuring appropriate monitoring for such implants.

Methods

We present the results of the first 540 V40TM Exeter THAs performed in our Centre between December 2000 and May 2002. All patients were reviewed prospectively at 1, 5 and 10 years following surgery.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 39 - 39
1 Jun 2016
Sandiford N Wilson M Hubble M Jameson S Howell J
Full Access

Introduction

Revision of well cemented femoral components in revision THA can be technically challenging and time consuming. The cement in cement (CiC) technique addresses these issues. Results of femoral components which have undergone multiple CiC revisions have not previously been reported.

Objective

We present the clinical and radiological results of femoral components which have undergone multiple CiC revisions with a minimum follow up of 5 years.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_12 | Pages 40 - 40
1 Nov 2015
Sathu A Timperley A Hubble M Wilson M Whitehouse S Howell J
Full Access

Introduction

There is sparse evidence regarding the survivorship beyond 20 years of both uncemented and cemented hip replacements in patients 50 years and under. We report a unique series reviewing 20–26 year follow-up of patients ≤50 years with cemented Exeter THR.

Materials and Methods

We reviewed the survivorship with clinical and radiological outcomes of 138 consecutive cemented THR's in 113 patients ≤50 years. The pre-op diagnoses included Osteoarthritis (30%), DDH (25%), RA (9%) and Post traumatic OA (5%), and 31% of patients had previous surgery to the hip. All patients were followed up at 5 year intervals and there was no patient lost to follow up.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_9 | Pages 26 - 26
1 May 2014
Rodger M Armstrong A Charity J Hubble M Howell J Wilson M Timperley J Refell A
Full Access

The management of patients with displaced intra-capsular hip fractures is usually a hip hemiarthoplasty procedure. NICE guideline 124 published in 2011 suggested that Total Hip Replacement (THR) surgery should be considered in a sub group of patients with no cognitive impairment, who walk independently and are medically fit for a major surgical procedure.

The Royal Devon and Exeter Hospital manages approximately 550 patients every year who have sustained a fracture of neck of femur, of which approximately 90 patients fit the above criteria. Prior to the guideline less than 20% of this sub-group were treated with a THR whereas after the guideline over 50% of patients were treated with THR, performed by sub-specialist Hip surgeons.

This practice is financially viable; there is no apparent difference in the overall cost of treating patients with THR. The effect of adoption of the NICE guideline was examined using 100 % complete data from 12 month post operative follow up. Only the Hemi-arthroplasty patients were significantly less likely to have stepped down a rung of independent living. Both THR and Hemi-arthroplasty patients were significantly less likely to have stepped down a rung of walking ability, but there was no significant difference between THR and Hemi-arthroplasty groups. Revision rates remained negligible.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_26 | Pages 23 - 23
1 Jun 2013
Rodger M Armstrong A Hubble M Refell A Charity J Howell J Wilson M Timperley J
Full Access

The management of patients with displaced intra-capsular hip fractures is usually a hip hemiarthoplasty procedure. NICE guideline 124 published in 2011 suggested that Total Hip Replacement (THR) surgery should be considered in a sub group of patients with no cognitive impairment, who walk independently and are medically fit for a major surgical procedure.

The Royal Devon and Exeter Hospital manages approximately 600 patients every year who have sustained a fracture of neck of femur, of which approximately 90 patients fit the above criteria. Prior to the guideline less than 20% of this sub-group were treated with a THR whereas after the guideline over 50% of patients were treated with THR, performed by sub-specialist Hip surgeons. This change was achieved by active leadership, incorporation of ‘Firebreak’ lists, looking for cases, flexible use of theatre time and operating lists and the nomination of an individual senior doctor who was tasked with a mission to improve practice.

This practice is financially viable; the Trust makes over £1000 per THR for fracture. Complete outcome data at 120 days show significantly fewer patients stepping down a rung in terms of both independent living and independent walking.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_9 | Pages 11 - 11
1 Feb 2013
Kassam A Evans J Guyver P Hubble M
Full Access

Femoral neck stress fractures (FNSF) are uncommon, representing 3.5% to 8% of all stress fractures in military recruits. The majority of displaced FNSF undergo operative fixation and are at risk of avascular necrosis (AVN) and non union with a 40–100% medical discharge rate. We aimed to review the incidence and outcome of displaced FNSF in Royal Marine Recruits.

Retrospective review identified 6 Royal Marine recruits, aged 17 to 25, who had suffered a displaced FNSF over a 6 and a half year period. Incidence was 0.93 per 1000 recruits.

Patients were treated urgently by operative fixation with a 2 hole dynamic hip screw device, in 3 cases supplemented with an anti-rotation screw. There were no cases of AVN, no surgical complications and no further procedures were required. All united with a mean time to union of 11 months. 50% had a union time greater than 1 year. 2 completed training, 2 are still in rehabilitation and 2 (33%) were discharged before completion of training.

These fractures are slow to unite compared to other fractures at this site or stress fractures elsewhere. With urgent surgical intervention and stable fixation all however went onto successful union with time and all returned to rehabilitation or training with minimal complications. Awareness of the length of time to union has been invaluable in guiding treatment and rehabilitation. It can help avoid the risks of unnecessary secondary interventions for delay to union.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 169 - 169
1 Sep 2012
Bartlett G Wilson M Whitehouse S Hubble M Gie G Timperley J Howell J
Full Access

We present 346 consecutive revision procedures for aseptic loosening with acetabular impaction bone grafting (AIBG) and a cemented polyethylene cup. Defects were contained with mesh alone. Mean follow up of 6.6 years, range 8 days-13 years. The Oxford Hip (OHS) and Harris Hip (HHS) scores were collected prospectively. Radiological definition of cup failure was either > 5mm displacement, or > 5° rotation. Cox regression analysis was performed on ten separate patient and surgical factors to determine their significance on survivorship.

Kaplan Meier survivorship at 10 years (42 cases remaining at risk) for aseptic loosening was 87% (95% confidence Interval (CI): 81.6 to 92.2) and 85.6% (95% CI: 80.3 to 90.9) for all revisions. These results are comparable to other reported series utilising AIBG. However, there were 88 cases (25%) that exceeded the radiological migration parameters, but their functional scores were not significantly different to the non-migrators: OHS p=0.273, HHS p=0.16. The latest post-operative mean OHS was 33 (SD 10.66). Female gender (p=0.039), increasing graft thickness (p=0.006) and the use of mesh (p=0.037) were significant risk factors for revision, but differing techniques in graft preparation, including artificial graft expanders (p=0.73), had no significant effect when analysed using Cox regression.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 167 - 167
1 Sep 2012
Bolland B Whitehouse S Howell J Hubble M Gie G Timperley A
Full Access

This study utilised NJR primary hip data from the 6th Annual Report to determine the rate and indication for revision between cemented, uncemented, hybrid and resurfacing prosthetic groups. Regression analysis was performed to identify the influence of gender and ASA grade on these revision rates. Validity of the data was interrogated by exploring for episodes of misclassification.

Results

We identified 2,264 misclassified episodes within the four groups (Misclassification rate 2.7% primary, 4.3% revision procedures). Analysis was performed using the “reclassified dataset”.

The Kaplan-Meier revision rates at 3 years were 0.9% (95%CI: 0.8%-1.0%) for cemented prostheses, 1.9% (95%CI: 1.8%-2.0%) for uncemented hips, 1.2% (95%CI: 1.0%-1.4%) for hybrids and 3.0%, (95%CI: 2.7%-3.3%) in the resurfacing group. The trends in revision rates were comparable to those published in the NJR (6th Edn.) with significant differences across all groups (p< 0.0001). Revision rates in the under 55 year age group showed an identical hierarchy with cemented and hybrid arthroplasty having the lowest revision rates.

Cox Regression analysis indicated that both the prosthesis group in isolation and the interaction between prosthesis group and ASA grade significantly influenced the rate of failure (p< 0.001).

Indications for revision showed significant differences in rates for, pain, aseptic loosening, dislocation and malalignment between prosthesis types (p< 0.001). The indications including Aseptic loosening, pain, malalignment and dislocation all demonstrated similar trends in revision rates between prosthetic groups with cemented hips having the lowest rates followed by ascending rates for hybrid, uncemented and resurfacing groups. The exception being dislocation with resurfacings having the lowest revision rates.

Discussion

This study provides important baseline revision rates by indication for each prosthetic group from which future comparisons can be made. Areas of misclassification within the NJR dataset have been reported back for future annual analysis.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 168 - 168
1 Sep 2012
Bolland B Howell J Hubble M Timperley A Gie G Ling R
Full Access

Background

Since 1991 to 2008 approximately 800,000 Exeter stems have been sold worldwide with 80 reported cases of fracture (neck or stem). This study aimed to determine factors predisposing to fracture.

Method

Clinical, surgical, radiological and retrieval data was collated from Stryker Benoist-Girard and Exeter research databases. Risk factors associated with fracture were categorised to patient related (weight and activity levels), surgical related (poor medial support, component size, placement) and implant related (+ head).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 58 - 58
1 May 2012
Hubble M Williams D Crawford R Timperley J Gie G
Full Access

Favourable long-term results have been reported with the standard Exeter cemented stem. We report our experience with a version for use in smaller femora, the Exeter 35.5 mm stem. Although, also a collarless polished taper, the stem is slimmer and 25 mm shorter than a standard stem.

Between August 1988 and August 2003, 192 primary hip arthroplasties were performed in 165 patients using the Exeter 35.5 mm stem. Clinical and operative data were collected prospectively. Clinical evaluation was by the Charnley, Harris and Oxford hip scores and radiographs were analysed post-operatively and at latest follow up.

The mean age at time of operation was 53 years (18 to 86), with 73 patients under the age of 50 years. The diagnosis was osteoarthritis in 91, hip dysplasia in 77, inflammatory arthritis in 18, septic arthritis of the hip in three, secondary to Perthes disease in two and avascular necrosis of the hip in one patient. The fate of every implant is known.

At a median follow-up of 8 years (5 to 19), survivorship with revision of the femoral stem for aseptic loosening as the endpoint was 100%. Fifteen cases (7.8%) underwent further surgery 11 for acetabular revision, one for stem fracture and three others.

Although, smaller than a standard Exeter Universal polished tapered cemented stem—with a shorter, slimmer taper—the performance of the Exeter 35.5 mm stem was equally good even in this young, diverse group of patients.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 62 - 62
1 May 2012
Wilson M Hubble M Howell J Gie G Timperley J Crawford R
Full Access

Impaction bone grafting (IBG) of the acetabulum in cemented primary total hip replacement is a useful technique in the management of acetabular deficiencies. It has the capacity to restore anatomy and bone stock with good long-term outcome. We present 125 consecutive cases of IBG with a cemented polyethylene component. All patients who received full IBG of the acetabulum in primary cemented Exeter total hip replacements and who underwent surgery between August 1995 and August 2003 were identified. All operative and follow-up data was collected prospectively and no patients were lost to follow-up. All patients underwent pre-operative and regular post-operative hip scores with the Harris, Oxford and the modified Charnley scoring systems. Data on indication, surgical technique, socket position and migration and revision was reviewed at a mean follow-up of 7.6 (range 5 to13.4) years.

Between August 1995 and August 2003, 113 patients (85 females) with an average age of 67.8 (range 22.9–99.2) years underwent 125 primary Exeter cemented total hip replacements with IBG of acetabular defects. Acetabular defects were classified according to the AAOS classification as cavitatory in 62 hips and as segmental, requiring application of a rim mesh prior to IBG, in 63 hips. Life tables were constructed demonstrating 86.4% survival of the acetabular component at 13.4 years with revision for any reason as the endpoint and 89.3% survival with revision for aseptic loosening as the endpoint. Of the seven patients who underwent revision for aseptic loosening, all had pre-operative segmental acetabular defects requiring application of a rim mesh. No patient who underwent IBG for a cavitatory defect required revision surgery for aseptic loosening. Survival of the Exeter cemented femoral component was 100% at 13.4 years with revision for aseptic loosening as the endpoint. There were 11 radiographic failures of the acetabular component, which have not been revised at latest review. One of these is symptomatic but not fit for revision surgery, two were asymptomatic at time of death and eight are asymptomatic but under review.

This is the largest series of IBG in the acetabulum in cemented primary THR. Our results suggest that the medium term survival of this technique is good, particularly when used for cavitatory defects. Although there were radiographic failures, these are largely asymptomatic and may not require revision.