header advert
Results 1 - 9 of 9
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1662 - 1668
1 Nov 2021
Bhanushali A Chimutengwende-Gordon M Beck M Callary SA Costi K Howie DW Solomon LB

Aims

The aims of this study were to compare clinically relevant measurements of hip dysplasia on radiographs taken in the supine and standing position, and to compare Hip2Norm software and Picture Archiving and Communication System (PACS)-derived digital radiological measurements.

Methods

Preoperative supine and standing radiographs of 36 consecutive patients (43 hips) who underwent periacetabular osteotomy surgery were retrospectively analyzed from a single-centre, two-surgeon cohort. Anterior coverage (AC), posterior coverage (PC), lateral centre-edge angle (LCEA), acetabular inclination (AI), sharp angle (SA), pelvic tilt (PT), retroversion index (RI), femoroepiphyseal acetabular roof (FEAR) index, femoroepiphyseal horizontal angle (FEHA), leg length discrepancy (LLD), and pelvic obliquity (PO) were analyzed using both Hip2Norm software and PACS-derived measurements where applicable.


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1455 - 1462
1 Nov 2018
Munro JT Millar JS Fernandez JW Walker CG Howie DW Shim VB

Aims

Osteolysis, secondary to local and systemic physiological effects, is a major challenge in total hip arthroplasty (THA). While osteolytic defects are commonly observed in long-term follow-up, how such lesions alter the distribution of stress is unclear. The aim of this study was to quantitatively describe the biomechanical implication of such lesions by performing subject-specific finite-element (FE) analysis on patients with osteolysis after THA.

Patients and Methods

A total of 22 hemipelvis FE models were constructed in order to assess the transfer of load in 11 patients with osteolysis around the acetabular component of a THA during slow walking and a fall onto the side. There were nine men and two women. Their mean age was 69 years (55 to 81) at final follow-up. Changes in peak stress values and loads to fracture in the presence of the osteolytic defects were measured.


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 458 - 464
1 Apr 2017
Abrahams JM Kim YS Callary SA De Ieso C Costi K Howie DW Solomon LB

Aims

This study aimed to determine the diagnostic performance of radiographic criteria to detect aseptic acetabular loosening after revision total hip arthroplasty (THA). Secondary aims were to determine the predictive values of different thresholds of migration and to determine the predictive values of radiolucency criteria.

Patients and Methods

Acetabular component migration to re-revision was measured retrospectively using Ein-Bild-Rontgen-Analyse (EBRA-Cup) and manual measurements (Sutherland method) in two groups: Group A, 52 components (48 patients) found not loose at re-revision and Group B, 42 components (36 patients) found loose at re-revision between 1980 and 2015. The presence and extent of radiolucent lines was also assessed.


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 465 - 474
1 Apr 2017
Kim YS Abrahams JM Callary SA De Ieso C Costi K Howie DW Solomon LB

Aims

The purpose of this study was to determine the sensitivity, specificity and predictive values of previously reported thresholds of proximal translation and sagittal rotation of cementless acetabular components used for revision total hip arthroplasty (THA) at various times during early follow-up.

Patients and Methods

Migration of cementless acetabular components was measured retrospectively in 84 patients (94 components) using Ein-Bild-Rontgen-Analyse (EBRA-Cup) in two groups of patients. In Group A, components were recorded as not being loose intra-operatively at re-revision THA (52 components/48 patients) and Group B components were recorded to be loose at re-revision (42 components/36 patients).


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1038 - 1045
1 Aug 2015
Solomon LB Costi K Kosuge D Cordier T McGee MA Howie DW

The outcome of 219 revision total hip arthroplasties (THAs) in 98 male and 121 female patients, using 137 long length and 82 standard length cemented collarless double-taper femoral stems in 211 patients, with a mean age of 72 years (30 to 90) and mean follow-up of six years (two to 18) have been described previously. We have extended the follow-up to a mean of 13 years (8 to 20) in this cohort of patients in which the pre-operative bone deficiency Paprosky grading was IIIA or worse in 79% and 73% of femurs with long and standard stems, respectively.

For the long stem revision group, survival to re-revision for aseptic loosening at 14 years was 97% (95% confidence interval (CI) 91 to 100) and in patients aged > 70 years, survival was 100%. Two patients (two revisions) were lost to follow-up and 86 patients with 88 revisions had died. Worst-case analysis for survival to re-revision for aseptic loosening at 14 years was 95% (95% CI 89 to 100) and 99% (95% CI 96 to 100) for patients aged > 70 years. One additional long stem was classified as loose radiographically but not revised.

For the standard stem revision group, survival to re-revision for aseptic loosening at 14 years was 91% (95% CI 83 to 99). No patients were lost to follow-up and 49 patients with 51 hips had died. No additional stems were classified as loose radiographically.

Femoral revision using a cemented collarless double-taper stem, particularly with a long length stem, and in patients aged > 70 years, continues to yield excellent results up to 20 years post-operatively, including in hips with considerable femoral metaphyseal bone loss.

Cite this article: Bone Joint J 2015;97-B:1038–45.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1155 - 1160
1 Sep 2014
Kosuge D Cordier T Solomon LB Howie DW

Peri-acetabular osteotomy is an established surgical treatment for symptomatic acetabular dysplasia in young adults. An anteroposterior radiograph of the pelvis is commonly used to assess the extent of dysplasia as well as to assess post-operative correction. Radiological prognostic factors include the lateral centre-edge angle, acetabular index, extrusion index and the acetabular version. Standing causes a change in the pelvis tilt which can alter certain radiological measurements relative to the supine position. This article discusses the radiological indices used to assess dysplasia and reviews the effects of patient positioning on these indices with a focus on assessment for a peri-acetabular osteotomy. Intra-operatively, fluoroscopy is commonly used and the implications of using fluoroscopy as a modality to assess the various radiological indices along with the effects of using an anteroposterior or posteroanterior fluoroscopic view are examined. Each of these techniques gives rise to a slightly different image of the pelvis as the final image is sensitive to the position of the pelvis and the projection of the x-ray beam.

Cite this article: Bone Joint J 2014;96-B:1155–60.


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 48 - 53
1 Jan 2014
Solomon LB Hofstaetter JG Bolt MJ Howie DW

We investigated the detailed anatomy of the gluteus maximus, gluteus medius and gluteus minimus and their neurovascular supply in 22 hips in 11 embalmed adult Caucasian human cadavers. This led to the development of a surgical technique for an extended posterior approach to the hip and pelvis that exposes the supra-acetabular ilium and preserves the glutei during revision hip surgery. Proximal to distal mobilisation of the gluteus medius from the posterior gluteal line permits exposure and mobilisation of the superior gluteal neurovascular bundle between the sciatic notch and the entrance to the gluteus medius, enabling a wider exposure of the supra-acetabular ilium. This technique was subsequently used in nine patients undergoing revision total hip replacement involving the reconstruction of nine Paprosky 3B acetabular defects, five of which had pelvic discontinuity. Intra-operative electromyography showed that the innervation of the gluteal muscles was not affected by surgery. Clinical follow-up demonstrated good hip abduction function in all patients. These results were compared with those of a matched cohort treated through a Kocher–Langenbeck approach. Our modified approach maximises the exposure of the ilium above the sciatic notch while protecting the gluteal muscles and their neurovascular bundle.

Cite this article: Bone Joint J 2014;96-B:48–53.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 879 - 886
1 Jul 2007
Howie DW Wimhurst JA McGee MA Carbone TA Badaruddin BS

We investigated 219 revisions of total hip replacement (THR) in 211 patients using a collarless double-taper cemented femoral component. The mean age of the patients was 72 years (30 to 90). The 137 long and 82 standard length stems were analysed separately. The mean follow-up was six years (2 to 18), and no patient was lost to follow-up.

Survival of the long stems to re-revision for aseptic loosening at nine years was 98% (95% confidence interval (CI) 94 to 100), and for the standard stems was 93% (95% CI 85 to 100). At five years, one long stem was definitely loose radiologically and one standard stem was probably loose. Pre-operative femoral bone deficiency did not influence the results for the long stems, and corrective femoral osteotomy was avoided, as were significant subsidence, major stress shielding and persistent thigh pain.

Because of these reliable results, cemented long collarless double-taper femoral components are recommended for routine revision THR in older patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 573 - 576
1 Jul 1998
Howie DW Middleton RG Costi K

We have compared prospectively the incidence of loosening of 20 femoral stems with a matt surface with that of 20 polished stems of an otherwise identical tapered, non-modular design of Exeter hip replacement. The stems were inserted using the same technique at operation and radiographs showed no difference in the adequacy of the cement mantle or of fixation. All the patients were reviewed regularly and none was lost to follow-up.

After a minimum follow-up of nine years, four matt but no polished stems had been revised for aseptic loosening. Polished stems subsided slightly within the cement mantle early, but did not loosen.