header advert
Results 1 - 7 of 7
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 376 - 385
1 Mar 2022
Gramlich Y Hofmann L Kress S Ruckes C Kemmerer M Klug A Hoffmann R Kremer M

Aims

This study compared the cobalt and chromium serum ion concentration of patients treated with two different metal-on-metal (MoM) hinged total knee arthroplasty (TKA) systems, as well as a titanium nitride (TiN)-coated variant.

Methods

A total of 63 patients (65 implants) were treated using either a MoM-coated (n = 29) or TiN-coated (n = 7) hinged TKA (GenuX mobile bearing, MUTARS; Implantcast, Germany) versus the BPKS (Brehm, Germany) hinged TKA (n = 27), in which the weight placed on the MoM hinge is diffused through a polyethylene (PE) inlay, reducing the direct load on the MoM hinge. Serum cobalt and chromium ion concentrations were assessed after minimum follow-up of 12 months, as well as functional outcome and quality of life.


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1618 - 1619
1 Dec 2020
Klug A Nagy A Gramlich Y Hoffmann R


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1620 - 1628
1 Dec 2020
Klug A Nagy A Gramlich Y Hoffmann R

Aims

To evaluate the outcomes of terrible triad injuries (TTIs) in mid-term follow-up and determine whether surgical treatment of the radial head influences clinical and radiological outcomes.

Methods

Follow-up assessment of 88 patients with TTI (48 women, 40 men; mean age 57 years (18 to 82)) was performed after a mean of 4.5 years (2.0 to 9.4). The Mayo Elbow Performance Score (MEPS), Oxford Elbow Score (OES), and Disabilities of the Arm, Shoulder and Hand (DASH) score were evaluated. Radiographs of all patients were analyzed. Fracture types included 13 Mason type I, 16 type II, and 59 type III. Surgical treatment consisted of open reduction and internal fixation (ORIF) in all type II and reconstructable type III fractures, while radial head arthroplasty (RHA) was performed if reconstruction was not possible.


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1512 - 1519
1 Dec 2019
Klug A Konrad F Gramlich Y Hoffmann R Schmidt-Horlohé K

Aims

The aim of this study was to evaluate the outcome of Monteggia-like lesions at midterm follow-up and to determine whether the surgical treatment of the radial head influences the clinical and radiological results.

Patients and Methods

A total of 78 patients with a Monteggia-like lesion, including 44 women and 34 men with a mean age of 54.7 years (19 to 80), were available for assessment after a mean 4.6 years (2 to 9.2). The outcome was assessed using the Mayo Elbow Performance Score (MEPS), Oxford Elbow Score (OES), Mayo Modified Wrist Score (MMWS), and The Disabilities of the Arm, Shoulder and Hand (DASH) score. Radiographs were analyzed for all patients. A total of 12 Mason type I, 16 type II, and 36 type III fractures were included. Surgical treatment consisted of screw fixation for all type II and reconstructable type III fractures, while radial head arthroplasty (RHA) or excision was performed if reconstruction was not possible.


Bone & Joint Research
Vol. 3, Issue 7 | Pages 223 - 229
1 Jul 2014
Fleiter N Walter G Bösebeck H Vogt S Büchner H Hirschberger W Hoffmann R

Objective

A clinical investigation into a new bone void filler is giving first data on systemic and local exposure to the anti-infective substance after implantation.

Method

A total of 20 patients with post-traumatic/post-operative bone infections were enrolled in this open-label, prospective study. After radical surgical debridement, the bone cavity was filled with this material. The 21-day hospitalisation phase included determination of gentamicin concentrations in plasma, urine and wound exudate, assessment of wound healing, infection parameters, implant resorption, laboratory parameters, and adverse event monitoring. The follow-up period was six months.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 185 - 185
1 May 2011
Piltz S Rubenbauer B Pieske O Reiser M Hoffmann R
Full Access

Introduction: Percutaneous iliosacral screws are commonly used for the fixation of the posterior pelvis. The procedure is technically demanding because of the limitations of radiological visualisation of the relevant landmarks. There have been several reports of misplaced screws and other complications, occasionally with serious consequences. To achieve a secure surgical procedure we routinely use a CT-guided technique for percutaneous pelvic screw fixation since 2004.

Methods: Between September 2004 and January 2009, 39 patients were treated using CT-guided screw fixation. Under general anaesthesia patients were placed on a vacuum mattress in a stable lateral position within the CT gantry (Siemens SOMATOM definition; i-Fluoro: 20mAs; Hand CARE mode). The scanner bed was on a calibrated track so the same images could be used and repeated throughout the procedure. Gantry and patient were draped under sterile conditions. The laser sights of the CT indicated the cutaneous site which corresponded to the underlying osseous level (first or second sacral pedicle). At this the CT scan trajectory in the CT-fluoro mode indicated the extrapolated position of the guide-wire. A 3.2mm guide-wire was inserted using battery-powered equipment or hammer blows. When the guide-wire was in a correct position a self-drilling cannulated lag screw was placed (6.5mm DePuy). Two screws were inserted in sacral fractures, one screw in sacroiliac ligament ruptures.

Results: 19 of 39 patients were polytraumatized. In 10 cases there were both side injures. Overall 71 screws were placed. Median time for the procedure was 36 minutes in unilateral lesions and 48 min in bilateral lesions. There were no cases of infection, non-union or neurological deficit. Postoperative CT revealed correct screw positions in all cases. Screw removal was done routinely in the patients younger than sixty years to resolve the blocked sacroiliac joint.

Conclusions: CT-guided is a safe and feasible treatment option in patient with instable pelvic ring lesions. A close collaboration between interventional radiologist and surgeon is essential. Compared to other procedures g.e. internal plate fixation or fluoroscopic guided procedures CT-guided screw insertion seems to be more secure and could strongly be advocated.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 558 - 559
1 Oct 2010
Schmidt-Horlohé K Bonk A Hoffmann R Wilde P
Full Access

Patients and Methods: Between December 2005 until January 2008 34 distal humerus fractures in 33 patients were prospectively documented and treated using the angular-stable LCP distal humerus plate system from Synthes/Switzerland. Patient median age was 54 (min 14/ max 88). Fracture types were classified according to the AO classification. Extraarticular A fractures were documented in 3 (9%) cases, partial intra-articular fractures (type B) were seen in 4 (12%) patients. Complete intraarticular fractures were found in 27 (79%) cases. Three fractures were grade I° open, 6 fractures were grade II° open according to the Gustilo classification. In median after 10 months (min 8/ max 20) follow up was performed. Due to lost to follow up in one patient functional outcome was measured in 32 patients. Functional results were evaluated using the Mayo Elbow Performence Score (MEPS).

Results: According to MEPS, predominantly excellent and good results were achieved. The intent of stable fracture fixation to allow early physical therapy was reached in 31 patients. Failure of osteosynthesis making operative revision necessary occurred in 3 patients (1x implant failure, 2x loss of reduction). Mean Mayo Elbow Performance Score was 91 points (min 88.5/ max 100). Mean range of motion for extension/flexion was 110° (min 80/ max 140) and 170° (min 125/max 180) for pronation/supination. Only one patient regained unrestricted extension, mean loss of extension was 21° (min 10/ max 40). Mean Flexion up to 131° was achieved (min 125/ max 140).

Postoperative complications were seen in eight cases (implant breakage, delayed union, lost of reduction).

Conclusion: Despite postoperative complications and revision surgery, functional results achieved using the angular-stable LCP distal Humerus system are good or excellent in the majority of patients. Through angular-stable and multidirectional screw options fixation of the distal fragment is sufficient and periostal blood supply could be protected. Especially in combination of intraarticular fractures and osteoporotic bone stock the use of the LCP distal Humerus plate system is suitable and permits early physical therapy, promising a benefit for the elbow function.