header advert
Results 1 - 6 of 6
Results per page:
The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1202 - 1206
1 Sep 2014
Kumar V Sharma S James J Hodgkinson JP Hemmady MV

Despite a lack of long-term follow-up, there is an increasing trend towards using femoral heads of large diameter in total hip replacement (THR), partly because of the perceived advantage of lower rates of dislocation. However, increasing the size of the femoral head is not the only way to reduce the rate of dislocation; optimal alignment of the components and repair of the posterior capsule could achieve a similar effect.

In this prospective study of 512 cemented unilateral THRs (Male:Female 230:282) performed between 2004 and 2011, we aimed to determine the rate of dislocation in patients who received a 22 mm head on a 9/10 Morse taper through a posterior approach with capsular repair and using the transverse acetabular ligament (TAL) as a guide for the alignment of the acetabular component. The mean age of the patients at operation was 67 years (35 to 89). The mean follow-up was 2.8 years (0.5 to 6.6). Pre- and post-operative assessment included Oxford hip, Short Form-12 and modified University of California Los Angeles and Merle D’Aubigne scores. The angles of inclination and anteversion of the acetabular components were measured using radiological software. There were four dislocations (0.78%), all of which were anterior.

In conclusion, THR with a 22 mm diameter head performed through a posterior approach with capsular repair and using the TAL as a guide for the alignment of the acetabular component was associated with a low rate of dislocation.

Cite this article: Bone Joint J 2014;96-B:1202–6.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 579 - 583
1 May 2008
Yiannakopoulos CK Chougle A Eskelinen A Hodgkinson JP Hartofilakidis G

Our study evaluated the reliability of the Crowe and Hartofilakidis classification systems for developmental dysplasia of the hip in adults. The anteroposterior radiographs of the pelvis of 145 patients with 209 osteoarthritic hips were examined twice by three experienced hip surgeons from three European countries and the abnormal hips were rated using both classifications. The inter- and intra-observer agreement was calculated.

Interobserver reliability was evaluated using weighted and unweighted kappa coefficients and for the Crowe classification, among the three pairs there was a minimum kappa coefficient with linear weighting of 0.90 for observers A and C and a maximum kappa coefficient of 0.92 for observers B and C. For the Hartofilakidis classification, the minimum kappa value was 0.85 for observers A and B, and the maximum value was 0.93 for observers B and C. With regard to intra-observer reliability, the kappa coefficients with linear weighting between the two evaluations of the same observer ranged between 0.86 and 0.95 for the Crowe classification and between 0.80 and 0.93 for the Hartofilakidis classification.

The reliability of both systems was substantial to almost perfect both for serial measurements by individual readers and between different readers, although the information offered was dissimilar.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1141 - 1142
1 Sep 2006
Phillips SJ Chavan R Porter ML Kay PR Hodgkinson JP Purbach B Reddick AH Frayne JM

We carried out a retrospective case-control study in 80 patients who underwent a revision total hip replacement. Group A (40 patients) received tranexamic acid and intra-operative cell salvage. Group B (40 patients) was a matched control group and did not receive this management. Each group was divided into four subgroups: revision of both components, revision of both components with bone grafting, revision of the acetabular component with or without bone graft, and revision of the femoral component with or without bone graft.

In group A the total number of units transfused was 52, compared with 139 in group B, representing a reduction in blood usage of 62.5%. The mean amount of blood transfused from cell salvage in each group was 858 ml (113 to 2100), 477 ml (0 to 2680), 228 ml (75 to 315) and 464 ml (120 to 1125), respectively. There was a significant difference in the amount of blood returned between the groups (p < 0.0001).

In group A, 22 patients needed transfusion and in group B, 37 (p < 0.0001). A cost analysis calculation showed a total revenue saving of £70 000 and a potential saving throughout our facility of £318 288 per year.

Our results show that a significant reduction in blood transfusion can be made using combined cell salvage and tranexamic acid in revision surgery of the hip.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_I | Pages 40 - 40
1 Mar 2005
Chougle A Hodgkinson JP
Full Access

Aim: To assess the factors affecting cup survivorship in cemented Total Hip Replacements carried out for DDH.

Methods: A retrospective study of 292 cemented total hip replacements carried out at Wrightington. The hips were classified according to the Crowe and Hartofilakidis classifications. Revision was used as the end point for prosthetic survivorship. The results were analysed statistically using SPSS for Windows.

Results: The mean age at time of surgery was 42.6 years with a mean follow-up of 15.7 years. The acetabulum was grafted in 48 cases. The commonest cause for revision was aseptic loosening of the acetabular component (88.3%). There was a higher rate of premature failure of the acetabular component with increasing severity of hip dysplasia, especially after 10years. There was a correlation with age of the patient, accelerated socket wear and previous pelvic osteotomy. There were higher rates of failure with the Charnley CDH stem and the offset bore cup.

Conclusion: Factors having an adverse effect on cup survival are severity of hip dysplasia, younger age at time of primary surgery, accelerated polyethylene wear and previous pelvic osteotomy. Bone grafting of the acetabulum and the operating surgeon did not influence long term cup survival.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 1 | Pages 16 - 20
1 Jan 2005
Chougle A Hemmady MV Hodgkinson JP

We have assessed the long-term results of 292 cemented total hip replacements which were performed for developmental dysplasia of the hip in 206 patients. The mean age of the patients at operation was 42.6 years (15.9 to 79.5) and most (202) were women. The severity of dysplasia was graded according to both the Crowe and the Hartofilakidis classifications. A 22.25-mm Charnley head was always used and the acetabular components were inserted with cement into the true acetabulum. Bone grafting of the acetabulum, using the patient’s own femoral head, was performed on 48 occasions.

At a mean follow-up of 15.7 years (2.2 to 31.2) the overall survival of the acetabular component was 78%. The main cause of revision was aseptic loosening (88.3%). The rate of survival at 20 years based on the Hartofilakidis classification was 76% in the dysplastic, 55% in the low-dislocation and 12% in the high-dislocation groups and on the Crowe classification, 72.7% for group I, 70.7% for group II, 36.7% for group III and 15.6% for group IV. There was no statistical correlation between bone grafting of the acetabulum and survival of the acetabular component. This study has shown a higher rate of failure of the acetabular component with increasing severity of hip dysplasia.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 73 - 73
1 Jan 2004
Ho K Clayson AD Day JB Sochart DH Hodgkinson JP
Full Access

Aims: As part of the guidelines recommended by NICE (National Institute of Clinical Excellent), we are presenting the early results of this new hip replacement component.

Methods: We reviewed 65 consecutive primary total hip replacements in 59 patients in which the Opera Flanged cemented acetabular component (smith & nephew) had been used. The mean follow-up was 47 months (36 to 63). In all cases a Charnley femoral prosthesis had been used. There were 39 women and 26 men with a mean age at operation of 67.4 years (33 to 90). Survival analysis of the acetabular components was performed.

Results: Two components were revised due to deep infection, and one of these cups was discovered to be well fixed at operation. None of the acetabular components required revision for aseptic loosening. After 5 years survival was 97% using the worst-case scenario. Radiological analysis of all acetabular components at 12 months post-operation and at yearly intervals revealed no cases of aseptic loosening. Radiolucencies around the cemented socket were noted in five patients, but were not progressive on sequential radiographs.

Conclusions: The early results are encouraging and the follow-up will be continued to assess the 10 years results.