Tsang J Gwynne P Gallagher M Simpson H
Full Access

Staphylococcus aureus is responsible for 60–70% infections of surgical implants and prostheses in Orthopaedic surgery, with cumulative treatment costs for all prosthetic joint infections estimated to be ∼ $1 billion per annum (UK and North America). Its ability to develop resistance or tolerance to a diverse range of antimicrobial compounds, threatens to halt routine elective implant surgery. One strategy to overcome this problem is to look beyond traditional antimicrobial drug therapies and investigate other treatment modalities. Biophysical modalities, such as ultrasound, are poorly explored, but preliminary work has shown potential benefit, especially when combined with existing antibiotics. Low intensity pulsed ultrasound is already licensed for clinical use in fracture management and thus could be translated quickly into a clinical treatment

Using a methicillin-sensitive S. aureus reference strain and the dissolvable bead assay, biofilms were challenged with gentamicin +/− low-intensity ultrasound (1.5MHz, 30mW/cm2, pulse duration 200µs/1KHz) for 180 minutes and 20 minutes, respectively. The primary outcome measures were colony-forming units/mL (CFU/mL) and the minimum biofilm eradication concentration (MBEC) of gentamicin. The mean number of S. aureus within control biofilms was 1.04 × 109 CFU/mL. Assessment of cellular metabolism was conducted using a liquid-chromatography-mass spectrometry, as well as a triphenyltetrazolium chloride assay coupled with spectrophotometry.

There was no clinically or statistically significant (p=0.531) reduction in viable S. aureus following ultrasound therapy alone. The MBEC of gentamicin for this S. aureus strain was 256 mg/L. The MBEC of gentamicin with the addition of ultrasound was reduced to 64mg/L. Metabolic activity of biofilm-associated S. aureus was increased by 25% following ultrasound therapy (p < 0 .0001), with identification of key biosynthetic pathways activated by non-lethal dispersal.

Low intensity pulsed ultrasound was associated with a four-fold reduction in the effective biofilm eradication concentration of gentamicin, bringing the MBEC of gentamicin to within clinically achievable concentrations. The mechanism of action was due to partial disruption of the extracellular matrix which led to an increase of nutrient availability and oxygen tension within the biofilm. This metabolic stimulus was responsible for the reversal of gentamicin tolerance in the biofilm-associated S. aureus.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_2 | Pages 43 - 43
1 Jan 2019
Tsang J Gwynne P Gallagher M Simpson H
Full Access

Staphylococcus aureus is responsible for 60–70% infections of surgical implants and prostheses in Orthopaedic surgery, costing the NHS £120–200 million per annum. Its ability to develop tolerance to a diverse range of antimicrobial compounds, threatens to halt routine elective implant surgery. One strategy to overcome this problem is to look beyond traditional antimicrobial drug therapies and investigate other treatment modalities. Biophysical modalities, such as ultrasound, are poorly explores, but preliminary work has shown potential benefit, especially when combined with existing antibiotics.

Using a methicillin-sensitive S. aureus reference strain and the dissolvable bead assay, bacterial biofilms were challenged by gentamicin +/− low-intensity ultrasound (1.5MHz, 30W/cm2, pulse duration 200µs/1KHz) for 20 minutes. The outcome measures were colony-forming units/mL (CFU/mL) and the minimum biofilm eradication concentration (MBEC) of gentamicin.

The mean number of S. aureus within control biofilms was 1.04 × 109 CFU/mL. There was no clinically or statistically significant (p=0.531) reduction in viable S. aureus following ultrasound therapy alone. The MBEC of gentamicin for this S. aureus strain was 256 mg/L. The MBEC of gentamicin with the addition of ultrasound was 64mg/L.

Low intensity pulsed ultrasound was associated with a four-fold reduction in the effective biofilm eradication concentration of gentamicin; bringing the MBEC of gentamicin to within clinically achievable concentrations


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_1 | Pages 1 - 1
1 Jan 2019
Tsang S Gwynne P Gallagher M Simpson A
Full Access

Staphylococcus aureus is responsible for 60–70% infections of surgical implants and prostheses in Orthopaedic surgery, costing the NHS £120–200 million per annum. Its ability to develop resistance or tolerance to a diverse range of antimicrobial compounds, threatens to halt routine elective implant surgery. One strategy to overcome this problem is to look beyond traditional antimicrobial drug therapies and investigate other treatment modalities. Biophysical modalities, such as ultrasound, are poorly explored, but preliminary work has shown potential benefit, especially when combined with existing antibiotics.

Using a methicillin-sensitive S. aureus reference strain and the dissolvable bead assay, biofilms were challenged by a low-intensity ultrasound (1.5MHz, 30mW/cm2, pulse duration 200µs/1KHz) for 20 minutes and gentamicin. The outcome measures were colony-forming units/mL (CFU/mL) and the minimum biofilm eradication concentration (MBEC) of gentamicin. The mean number of S. aureus within control biofilms was 1.04 × 109 CFU/mL. There was no clinically or statistically significant (p=0.531) reduction in viable S. aureus following ultrasound therapy alone. The MBEC of gentamicin for this S. aureus strain was 256 mg/L. The MBEC of gentamicin with the addition of ultrasound was 64mg/L. Further studies confirmed that the mechanism of action was due to incomplete disruption of the extracellular matrix with subsequent metabolic stimulation of the dormant biofilm-associated bacteria due to increased nutrient availability and oxygen tension.

Low intensity pulsed ultrasound was associated with a 4-fold reduction in the effective biofilm eradication concentration of gentamicin; bringing the MBEC of gentamicin to within clinically achievable concentrations.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 64 - 64
1 Apr 2018
Tsang J McHugh M Guerendiain D Gwynne P Boyd J Walsh T Laurenson I Templeton K Simpson H
Full Access

Introduction

Carriers of Staphylococcus aureus, both methicillin sensitive (MSSA) and methicillin resistant (MRSA), have an increased risk for health-care associated infections. Despite WHO recommendations there is currently no national screening and eradication policy for the detection of MSSA in the UK or USA. This study aimed to evaluate the effectiveness of current standard MRSA eradication therapies in the context of S. aureus decolonisation prior to joint replacement surgery.

Methods

Pre-operative PCR nasal screening was performed in 273 Orthopaedic patients awaiting joint replacement surgery. In all 100 patients were positive for S. aureus and enrolled into the study. All enrolled patients received and were instructed to administer the decolonisation regimen for five days. Prior to commencement of the eradication therapy swabs of the anterior nares, throat, and perineum were taken for culture. Further culture swabs were taken at; 48–96 hours after completion of the five-day eradication regimen, at hospital admission for surgery, and at hospital discharge. Patients were followed up for six weeks post-surgery. Following completion of the five-day course patients were asked to provide feedback on their experience using Likert rating scales. The primary outcome of this study was S. aureus clearance 48–96 hours post-completion of eradication therapy.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_19 | Pages 3 - 3
1 Nov 2017
Tsang S McHugh M Guerendiain D Gwynne P Boyd J Walsh T Laurenson I Templeton K Simpson A
Full Access

Nasal carriers of methicillin sensitive Staphylococcus aureus (MSSA) have an increased risk for health-care associated infections. There is currently no national screening policy for the detection of MSSA in the UK. This study aimed to: evaluate the diagnostic performance of molecular and culture techniques in MSSA screening, determine the cause of any discrepancy between the diagnostic techniques, and model the potential effect of different diagnostic techniques on MSSA detection in orthopaedic patients. Paired nasal swabs for PCR assay and culture of S. aureus were collected from a study population of 273 orthopaedic outpatients due to undergo joint replacement surgery.

The prevalence of MSSA nasal colonisation was found to be between 22.4–35.6%. The current standard direct culturing methods for detecting S. aureus significantly underestimated the prevalence (p=0.005), failing to identify its presence in ∼1/3 of patients undergoing joint replacement surgery.

Modelling these results to national surveillance data, it was estimated that 800–1200 MSSA surgical site infections could be prevented annually in the UK by using alternative diagnostic methods to direct culture in pre-operative MSSA screening and eradication programmes.