header advert
Results 61 - 64 of 64
Results per page:
Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 1 - 1
1 Mar 2008
Gupta S Cosker T Tayton K
Full Access

A study of 50 consecutive osteoporotic pelvic rami fractures has been carried out to investigate the full extent of injury following low energy falls.

50 consecutive elderly patients with fresh fractures of the pelvis were each investigated with an MRI scan of the pelvis in order to assess the competency of the pelvic ring. The 50 patients consisted of 45 female and 5 males with a mean age of 77.7 years. 44 patients had unilateral pubic rami fractures. The mechanism of injury in all cases was a simple fall in the home environment. On admission 96% of the patients complained of sacral pain and were tender in the sacral or posterior pelvic region. On MRI, 90% of patients had a sacral fracture associated with the pubic rami fractures and in all but 4 of these the posterior pelvic pain was directly related to the sacral fracture site. At 6 month follow-up, 82% still complained of posterior pelvic tenderness. Areas of tenderness corresponded to the sites of the fractures. Before the injury, 38 of the final 44 reviewed were reasonably independently mobile, whilst at review 39 were significantly disabled.

Conclusion: The study shows that the apparently benign traumatic pelvic rami fracture in the elderly has a high association with sacral fractures. After discharge from hospital, attention should be paid to treatment of the on-going anterior and posterior pelvic pain.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 377 - 381
1 Mar 2008
Canavese F Gupta S Krajbich JI Emara KM

Our aim was to review the efficacy of the wound vacuum-assisted closure (VAC) system in the treatment of deep infection after extensive instrumentation and fusion for spinal deformity in children and adolescents.

A total of 14 patients with early deep spinal infection were treated using this technique. Of these, 12 had neuromuscular or syndromic problems. Clinical and laboratory data were reviewed. The mean follow-up was 44 months (24 to 72). All wounds healed. Two patients required plastic surgery to speed up the process. In no patient was the hardware removed and there was no loss of correction or recurrent infection.

We believe that the wound VAC system is a useful tool in the armamentarium of the spinal surgeon dealing with patients susceptible to wound infections, especially those with neuromuscular diseases. It allows for the retention of the instrumentation and the maintenance of spinal correction. It is reliable and easy to use.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 495 - 495
1 Apr 2004
Wong W Gupta S Stewart F Ryan D
Full Access

Introduction Kirschner wire (K-wire) pinning is a widely accepted technique for fixation of distal radius fractures. Potential exists for injury to the soft tissues. This cadaveric study evaluates the safety of percutaneous pinning of distal radius fractures using a technique of intrafocal placement of K-wires.

Methods Three K-wires (1.6 mm diameter) were inserted percutaneously into 18 cadaveric wrists 18 mm proximal to the radial styloid. A radial wire was placed between the first and second extensor compartments. A dorso-radial wire was placed proximal to Lister’s tubercle. A dorsoulnar wire was placed between the fourth and fifth compartments. The wrists were dissected along the wires to the bone.

Results The superficial radial nerve (SRN) was pierced twice (11%), the abductor pollicis longus six times (33%), the extensor pollicis brevis and the extensor carpiradialis brevis once (6%). Extensor pollicis longus (EPL) was entered five times (28%), the fourth compartment four times (22%) and the fifth compartment once (6%). Only four wrists (22%) escaped injury to any important structure.

Conclusions The incidence of SRN injury by percutaneous insertion of K-wires is similar to that reported for the mini-open approach of around 12%. Rupture of EPL has been reported at around two percent. Aetiology of rupture is unclear and a K-wire that is subsequently removed may not increase the risk of rupture.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 376 - 376
1 Mar 2004
Gupta S Dabke H Holt C OñCallaghan P Hayes N Dent C
Full Access

Aim: To ascertain the accuracy of partial weight bearing.

Method: 6 healthy volunteers with a below knee plaster cast, 10 patients with uncemented hip replacements and 12 patients with lower limb fractures were trained to partial weight bear. They were asked to place the affected leg on a bathroom scale and to press on it till the prescribed limit. This process was repeated till the subject formed a mental image of the amount of load they must put through the limb. The ability to partial weight bear was tested in a gait lab by making them walk on a walkway incorporating a Bertec force platform. Exact magnitude of weight bearing was calculated from the vertical ground reaction forces produced.

Results: 4 out of 6 volunteers exerted mean weight of 20.3 kg above and the remaining 2 exerted 5.6 kg below that prescribed. Of the 22 patients, 19 exerted mean weight of 24.3 kg above and 3 patients exerted mean weight of 7.5 kg below that prescribed. As per Spearmanñs rank correlation test, the relationship between the prescribed weight bearing and the actual weight bearing was non-signiþcant (p=0.399) i.e., there is little relationship between the prescribed and actual weight bearing.

Conclusions: Neither patients nor healthy volunteers could partial weight bear to the extent required. They were either above or below the prescribed level of partial weight bearing. Current method of teaching partial weight bearing is inaccurate and has poor reproducibility. Such methods use static loading situations whereas walking is a dynamic activity. An inexpensive, easy to use, dynamic device is required to train patients to partial weight bear.