header advert
Results 1 - 2 of 2
Results per page:
Bone & Joint Open
Vol. 1, Issue 10 | Pages 628 - 638
6 Oct 2020
Mott A Mitchell A McDaid C Harden M Grupping R Dean A Byrne A Doherty L Sharma H

Aims

Bone demonstrates good healing capacity, with a variety of strategies being utilized to enhance this healing. One potential strategy that has been suggested is the use of stem cells to accelerate healing.

Methods

The following databases were searched: MEDLINE, CENTRAL, EMBASE, Cochrane Database of Systematic Reviews, WHO-ICTRP, ClinicalTrials.gov, as well as reference checking of included studies. The inclusion criteria for the study were: population (any adults who have sustained a fracture, not including those with pre-existing bone defects); intervention (use of stem cells from any source in the fracture site by any mechanism); and control (fracture healing without the use of stem cells). Studies without a comparator were also included. The outcome was any reported outcomes. The study design was randomized controlled trials, non-randomized or observational studies, and case series.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_18 | Pages 12 - 12
1 Nov 2017
Reidy M Faulkner A Grupping R Mayne A Campbell D MacLean J
Full Access

Prophylactic fixation of the contralateral hip in cases of unilateral slipped capital femoral epiphysis (SCFE) remains contentious. Our senior author reported a 10 year series in 2006 that identified a rate of subsequent contralateral slip of 25percnt; when prophylactic fixation was not performed. This led to a change in local practice and employment of prophylactic fixation as standard. We report the 10 year outcomes following this change in practice.

A prospective study of all patients who presented with diagnosis of SCFE between 2004 and 2014 in our region. Intra-operative complication and post-operative complication were the primary outcomes. 31 patients presented during the study period: 16 male patients and 15 female patients. The mean age was 12.16 (8–16, SD 2.07). 25 patients had stable SCFE and 5 had unstable SCFE. Stability was uncertain in 1 patient. 25 patients had unilateral SCFE and 6 had bilateral SCFE. 24 patients who had unilateral SUFE had contralateral pinning performed. 1 unilateral SCFE did not have contralateral pinning performed as there was partial fusion of physis on contralateral side.

In the hips fixed prophylactically there was 1 cases of transient intraoperative screw penetration into the joint and 1 case of minor wound dehiscence. There were no cases or chondrolysis or AVN. There were no further contralateral slips. This change in practice has been adopted with minimal complication. The fixation of the contralateral side is not without risk but by adopting this model the risk of subsequent slip has been reduced from 25percnt; to 0percnt;.