header advert
Results 21 - 36 of 36
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 1 | Pages 145 - 146
1 Jan 1989
Irvine G Gregg P


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 1 | Pages 33 - 38
1 Jan 1989
Brenkel I Dias J Davies T Iqbal S Gregg P

In 15 consecutive patients with slipped capital femoral epiphysis we recorded height, weight and skeletal maturity. Sexual maturity was assessed clinically and biochemically, and Harris's hypothesis that there is an increased ratio of serum growth hormone to oestrogen was tested in comparison with 15 age and sex matched controls. We found no difference in skeletal or sexual maturity between the groups, or any overt endocrine abnormality in the patients. However almost half the patients with slipped epiphysis were over the 90th weight percentile, suggesting that mechanical factors such as obesity are more important aetiologically than endocrine abnormalities.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 787 - 790
1 Nov 1988
Oni O Hui A Gregg P

One hundred consecutive closed fractures of the adult tibial shaft treated by closed methods were surveyed prospectively in order to observe their natural history. The fractures were analysed with regards to speed of healing and the influence of age, sex, causal force, radiological morphology and concurrent fibular fracture. At 20 weeks 19 fractures had not yet united, but 15 of these had united by 30 weeks with conservative treatment alone. The remaining four cases were operated upon because no further progress in healing was anticipated. These findings suggest that, with regard to healing, open reduction and internal fixation is rarely justified in closed adult tibial shaft fractures.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 2 | Pages 299 - 301
1 Mar 1988
Dias J Taylor M Thompson J Brenkel I Gregg P

Inter-observer agreement and reproducibility of opinion were assessed for the radiographic diagnosis of union of scaphoid fractures on films taken 12 weeks after injury. Weighted kappa statistics were used to compare the opinions of eight senior observers reviewing 20 sets of good quality radiographs on two occasions separated by two months. There was poor agreement on whether trabeculae crossed the fracture line, whether there was sclerosis at or near the fracture and on whether the proximal part of the scaphoid was avascular. As a consequence, agreement on union also was poor; it appears that radiographs taken 12 weeks after a scaphoid fracture do not provide reliable and reproducible evidence of healing.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 2 | Pages 247 - 250
1 Mar 1988
Lowrie I Finlay D Brenkel I Gregg P

Thirty-six patients with 39 fresh fractures of the calcaneus were investigated by standard radiography and by computerised tomography. It was found that the size and disposition of the fracture fragments and the degree of involvement of the posterior facet of the subtalar joint were more clearly shown by CT scanning. We recommend this technique for assessment and particularly for pre-operative planning.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 1 | Pages 150 - 150
1 Jan 1988
Magnussen P Crozier A Gregg P


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 5 | Pages 719 - 722
1 Nov 1987
Dias J Steingold R Richardson R Tesfayohannes B Gregg P

The treatment of acromioclavicular injuries is controversial; few studies document the late results. We have reviewed 53 patients about five years after conservative management, in nine for subluxation and 44 for dislocation. Subjective and objective results were satisfactory in all cases except for one with painful subluxation, who was the only patient to change her occupation because of the injury. At review, joint stability was demonstrated by improvement in position and by the very small increase in the coracoclavicular gap on stress radiographs.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 5 | Pages 847 - 848
1 Nov 1987
O'Doherty D Lowrie I Gregg P


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 3 | Pages 463 - 467
1 May 1987
Dias J Wray C Jones J Gregg P

Unilateral Colles' fractures in 187 patients over the age of 55 years were studied in a randomised prospective trial: 97 fractures were minimally displaced and were treated either conventionally or in a crepe bandage; 90 displaced Colles' fractures were reduced and of these 47 were treated conventionally while 43 were encouraged to mobilise the wrist in a cast which restricted extension. Early wrist movement hastened functional recovery and led to earlier resolution of wrist swelling. Discomfort was no greater than in patients who were treated conventionally. The bony deformity, which recurred irrespective of the method of treatment, was not adversely affected by early mobilisation.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 1 | Pages 84 - 88
1 Jan 1987
Dias J Stirling A Finlay D Gregg P

Sixteen consecutive patients with tibial plateau fractures were investigated by standard radiography, biplanar tomography and computerised axial tomograms (CT scans). It was found that CT scanning proved most helpful for classifying the type of fracture, for evaluating the degree of comminution, and for measuring displacement. Moreover, because a single position was maintained throughout the investigation, the patients felt less discomfort than during other assessment procedures. For these reasons CT scanning is recommended for evaluating this type of fracture.


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 4 | Pages 564 - 566
1 Aug 1985
Howie C Smith G Christie J Gregg P

Torsion and subsequent ischaemia is a well-recognised cause of symptoms and morbidity in general surgery. We present three cases of solitary pigmented villonodular tumours of the knee which were found to have undergone torsion. We believe these to be the first intra-articular tumours in which torsion has been reported.


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 2 | Pages 239 - 242
1 Apr 1982
Thomas I Gregg P Walder D

Intra-osseous phlebography and the measurement of intramedullary pressure (IMP) have been used clinically and in experimental animals as qualitative methods of measuring blood flow in the bone. The normal phlebographic appearances in long bones are not clearly understood and the correlation between these appearances and the IMP is not known. The distal femora of 10 anaesthetised rabbits were cannulated percutaneously. The IMP was measured and phlebography performed by injecting a radio-opaque dye (Conray 280).The mean resting IMP was 33 millimetres of mercury with a range of 7 to 81 millimetres of mercury. The rate of elimination of dye from the marrow varied from less than 1 minute to 40 minutes. There was no correlation between the rate of elimination of dye and the IMP. Variation in the medullary phlebographic appearance and in the routes of drainage were noted. We concluded that the wide range of resting values for both techniques suggest that neither is a true measure of blood flow in the bone and that the results of research or clinical investigation using these techniques should be viewed with caution.


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 1 | Pages 132 - 137
1 Feb 1981
Gregg P Walder D

A group of patients were studied 10 years after stopping work in a high-pressure environment. Radiographs of their long bones showed little change during the period, but only two of 12 scintigrams were normal. The 10 abnormal scintigrams contained 18 "hot-spots" which were not always associated with an abnormal radiographic appearance; the findings suggest that some lesions may never become visible on a radiograph. A reactive or repair process associated with these lesions may be prolonged and may not be beneficial, as structural failure of the joint may subsequently occur. Prognosis should therefore be guarded.


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 2 | Pages 222 - 226
1 May 1980
Gregg P Walder D

In an attempt to explain the distribution of lesions of caisson disease of bone in the human femur, the regional distribution of circulating microspheres which had been labelled with scandium-46 was studies in the femur of the rabbit. Microspheres with a diameter of 15 microns were equally distributed between the two ends of the bone and between the upper and lower halves of the shaft. However, microspheres with a diameter of 50 microns congregated in the upper end of the femur and in the lower half of the shaft, the two sites most commonly affected by caisson disease. A large percentage of the microspheres in the shaft, especially the larger spheres, were retained in the marrow. It is suggested that the microcirculation of the marrow may act as a filter and that the nature and distribution of its vessels determine the site of impaction of circulating emboli. This would explain why lesions of the shaft mainly affect the medulla of the bone and not the cortex.


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 2 | Pages 214 - 221
1 May 1980
Gregg P Walder D

The early diagnosis of caisson disease of bone is hindered by the long delay which must elapse before an abnormality becomes apparent on a radiograph. The possible use of bone scintigraphy for this purpose was investigated. Necrosis of the bone and marrow was produced in rabbits by glass microspheres to simulate persistent gas-bubble emboli and then serial radiographs and scintigrams using 99mTc-diphosphonate were obtained. Regions of necrosis could be detected as "hot-spots" on the scintigrams as early as three weeks after the causative insult, which was many weeks before any abnormality could be detected on the radiographs. Histological examination of excised femora suggested that the scintigraphic abnormality might depend on the new bone formation during a reactive or repair process. It is suggested that scintigraphy may have clinical value in caisson disease.


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 1 | Pages 80 - 84
1 Feb 1977
Weatherley C Gregg P Walder D Rannie I

This paper reports a detailed examination of three lesions of aseptic necrosis of bone occurring in a man who had worked in compressed air eleven years previously. Although two of the lesions were juxta-articular, in neither had the bone collapsed. Histology of only one similar lesion is reported in the literature (McCallum et al. 1966). Necropsy material is considered, together with radiographs and bone scans of the same lesions taken four years earlier. Similar changes have been shown to occur in commercial divers. On the evidence of this case it becomes clear that radiography is limited in its use and that bone scans as an indicator of repair may be open to misinterpretation. There may be a place for operation before the onset of symptoms in these cases of aseptic bone necrosis.