header advert
Results 1 - 10 of 10
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 90 - 98
1 Jul 2020
Florissi I Galea VP Sauder N Colon Iban Y Heng M Ahmed FK Malchau H Bragdon CR

Aims

The primary aim of this paper was to outline the processes involved in building the Partners Arthroplasty Registry (PAR), established in April 2016 to capture baseline and outcome data for patients undergoing arthroplasty in a regional healthcare system. A secondary aim was to determine the quality of PAR’s data. A tertiary aim was to report preliminary findings from the registry and contributions to quality improvement initiatives and research up to March 2019.

Methods

Structured Query Language was used to obtain data relating to patients who underwent total hip or knee arthroplasty (THA and TKA) from the hospital network’s electronic medical record (EMR) system to be included in the PAR. Data were stored in a secure database and visualized in dashboards. Quality assurance of PAR data was performed by review of the medical records. Capture rate was determined by comparing two months of PAR data with operating room schedules. Linear and binary logistic regression models were constructed to determine if length of stay (LOS), discharge to a care home, and readmission rates improved between 2016 and 2019.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 24 - 24
1 Oct 2019
Florissi IS Galea VP Rojanasopondist P Sauder N Iban YEC Malchau H Bragdon CR
Full Access

Introduction

This analysis aims to provide an update of the Level-IV Partners Arthroplasty Registry (PAR), a quality-improvement initiative and research data repository.

Methods

The Harris Joint Registry was founded in 1969 and has since expanded to become the Partners Arthroplasty Registry (PAR). Today, the PAR captures data on total hip and total knee arthroplasties conducted at seven hospitals in Massachusetts. Over time, data has been sourced through independent collection at a single hospital, retrospective sourcing through the Research Patient Data Registry (RPDR), and currently through the Enterprise Data Warehouse (EDW). Various statistical methods analyzed changing trends of care provided to patients across affiliated institutions. PROMs collected in the PAR are the PROMIS Physical Function and Global Health Short Forms, the HOOS and KOOS. The registry is an associate member of ISAR and will incorporate the international implant library.


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 758 - 759
1 Jul 2019
Galea VP Rojanasopondist P Laursen M Muratoglu OK Malchau H Bragdon C


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 760 - 767
1 Jul 2019
Galea VP Rojanasopondist P Laursen M Muratoglu OK Malchau H Bragdon C

Aims

Vitamin E-diffused, highly crosslinked polyethylene (VEPE) and porous titanium-coated (PTC) shells were introduced in total hip arthroplasty (THA) to reduce the risk of aseptic loosening. The purpose of this study was: 1) to compare the wear properties of VEPE to moderately crosslinked polyethylene; 2) to assess the stability of PTC shells; and 3) to report their clinical outcomes at seven years.

Patients and Methods

A total of 89 patients were enrolled into a prospective study. All patients received a PTC shell and were randomized to receive a VEPE liner (n = 44) or a moderately crosslinked polyethylene (ModXLPE) liner (n = 45). Radiostereometric analysis (RSA) was used to measure polyethylene wear and component migration. Differences in wear were assessed while adjusting for body mass index, activity level, acetabular inclination, anteversion, and head size. Plain radiographs were assessed for radiolucency and patient-reported outcome measures (PROMs) were administered at each follow-up.


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 768 - 778
1 Jul 2019
Galea VP Rojanasopondist P Ingelsrud LH Rubash HE Bragdon C Huddleston III JI Malchau H Troelsen A

Aims

The primary aim of this study was to quantify the improvement in patient-reported outcome measures (PROMs) following total hip arthroplasty (THA), as well as the extent of any deterioration through the seven-year follow-up. The secondary aim was to identify predictors of PROM improvement and deterioration.

Patients and Methods

A total of 976 patients were enrolled into a prospective, international, multicentre study. Patients completed a battery of PROMs prior to THA, at three months post-THA, and at one, three, five, and seven-years post-THA. The Harris Hip Score (HHS), the 36-Item Short-Form Health Survey (SF-36) Physical Component Summary (PCS), the SF-36 Mental Component Summary (MCS), and the EuroQol five-dimension three-level (EQ-5D) index were the primary outcomes. Longitudinal changes in each PROM were investigated by piece-wise linear mixed effects models. Clinically significant deterioration was defined for each patient as a decrease of one half of a standard deviation (group baseline).


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1592 - 1599
1 Dec 2018
Galea VP Connelly JW Shareghi B Kärrholm J Sköldenberg O Salemyr M Laursen MB Muratoglu O Bragdon C Malchau H

Aims

The primary aim of this study was to compare the wear properties of vitamin E-diffused, highly crosslinked polyethylene (VEPE) and one formulation of moderately crosslinked and mechanically annealed ultra-high molecular weight polyethylene (ModXLPE) in patients five years after primary total hip arthroplasty (THA). The secondary aim was to assess the clinical results of patients treated with VEPE by evaluating patient-reported outcome measures (PROMs), radiological evidence of fixation, and the incidence of mechanical failure.

Patients and Methods

A total of 208 patients (221 THAs) from four international centres were recruited into a prospective study involving radiostereometric analysis (RSA) and the assessment of clinical outcomes. A total of 193 hips (87%) were reviewed at the five-year follow-up. Of these, 136 (70%) received VEPE (vs ModXLPE) liners and 68 (35%) received ceramic (vs metal) femoral heads. PROMs and radiographs were collected preoperatively and at one, two, and five years postoperatively. In addition, RSA images were collected to measure PE wear postoperatively and at one, two, and five years after surgery.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 48 - 48
1 Oct 2018
Galea VP Connelly JW Matuszak SJ Rojanasopondist P Bragdon CR Huddleston JI Rubash HE Malchau H
Full Access

Introduction

Within the field of arthroplasty, the use of patient-reported outcome measures (PROMs) is becoming increasingly ubiquitous in an effort to employ more patient-centered methods of evaluating success. PROMs may be used to assess general health, joint-specific pain or function, or mental health. General and joint-specific questionnaires are most often used in arthroplasty research, but the relationship between arthroplasty and mental health is less well understood. Furthermore, longitudinal reports of PROM changes after arthroplasty are lacking in the literature.

Our primary aim was to quantify the improvement in general, joint-specific, and mental health PROMs following total hip arthroplasty (THA) as well as the extent of any deterioration through the 7 years follow-up. Our secondary aim was to identify predictors of clinically significant PROM decline.

Methods

A total of 864 patients from 17 centers across 8 countries were enrolled into a prospective study. Patients were treated with components from a single manufacturer, which have been shown to be well-functioning in other studies.

Patients completed a battery of PROMs preoperatively, and at one, three, five, and seven years post-THA. Changes in PROMs between study visits were assessed via paired tests.

Postoperative trends for each PROM were determined for each subject by the slope of the best-fit line of the four postoperative data points. Significant PROM deterioration was defined as one literature-defined minimum clinically important difference over 5-years. Binary logistic regressions were used to identify independent predictors of significant decline in the EuroQol (EQ-5D) visual analogue scale (VAS) for Health State, 36-Item Short Form Survey (SF-36) physical composite summary (PCS), and SF-36 mental composite summary (MCS).


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 46 - 46
1 Oct 2018
Matuszak SJ Galea VP Rojanasopondist P Connelly JW Bragdon CR Huddleston JI Malchau H
Full Access

Introduction

The goal of the current study was to determine if SES affects PROMs in patients treated with THA. Specifically, we sought to determine any potential differences between low and high SES patients in pre-surgical PROMs, post-surgical PROMs, and PROM improvement after surgery while controlling for any potential confounding demographic factors.

Methods

Patients were selected from a clinical registry at an urban tertiary academic medical center. All patients undergoing primary THA between January 1, 2000 and April 1, 2016 were eligible for this study. During this period, patients were asked to complete the Harris Hip Score (HHS), Euro-QoL 5 Dimension (EQ-5D), 0–10 Numerical Rating Scale (NRS) Pain, 0–10 NRS Satisfaction (only given postoperatively), the Charnley Classifier, and the University of California Los Angeles (UCLA) Activity Score.

To determine SES, patients were matched by zip code to corresponding median household income as reported by the United States Census Bureau. Patients were then dichotomized into low and high SES groups using 2016 median household income of $57,617 USD as a cutoff point.

Statistical differences between low and high SES patients were determined for demographic factors, preoperative PROMs, postoperative PROMs, and PROM change. Non-parametric variables were tested with the Mann Whitney U test and categorical variables were tested with the Chi squared test.

Multivariate models were created to determine if SES group was independently predictive of achieving a minimal clinically important improvement (MCII) in PROMs (18.0 for HHS, −2.0 for NRS Pain, and 0.92 for UCLA). As potential confounders, we tested body mass index (BMI), preoperative health state from EQ-5D visual analog scale (EQ VAS), age at surgery, preoperative Charnley class, sex, and time between PROMs.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 47 - 47
1 Oct 2018
Rojanasopondist P Galea VP Connelly JW Matuszak SJ Bragdon CR Rolfson O Malchau H
Full Access

Introduction

As orthopaedics shifts towards value-based models of care, methods of evaluating the value of procedures such as a total hip arthroplasty (THA) will become crucial. Patient reported outcome measures (PROMs) can offer a meaningful way for patient-centered input to factor into the determination of value.

Despite their benefits, PROMs can be difficult to interpret as statistically significant, but not clinically relevant, differences between groups can be found. One method of correcting this issue is by using a minimal clinically important improvement (MCII), defined as the smallest improvement in a PROM determined to be important to patients.

This study aims to find demographic and surgical factors that are independently predictive of failing to achieve a MCII in pain and physical function at 1-year following THA.

Methods

A total of 976 patients were enrolled into a prospective international, multicenter study evaluating the long-term clinical performance of two acetabular shells and two polyethylene liners from a single manufacturer. All patients consented to be followed with plain radiographs and a set of PROMs preoperatively and at 1-year after surgery.

The outcomes considered in this study were achieving literature-defined MCIIs in pain and physical function at one year after THA. The MCII in pain was defined as achieving a 2-point decrease on the Numerical Rating Scale (NRS)-Pain or reporting a 1-year NRS-Pain value of 0, indicating no pain. The MCII in physical function was defined as achieving an 8.29-point increase on the SF-36 Physical Function subscore.

Univariate analyses were conducted to determine if there were statistically significant differences between patients who did achieve and did not achieve a MCII. Variables tested included: demographic and surgical factors, general and mental health state, and preoperative radiographic findings such as deformity and joint space width (JSW). Significant variables were entered into a multivariable binary logistic regression.

Receiver-operating characteristic (ROC) analysis was used to generate cutoff values for significant continuous variables. Youden's index was used to identify cutoff points that maximized both specificity and sensitivity.


The Bone & Joint Journal
Vol. 99-B, Issue 4_Supple_B | Pages 33 - 40
1 Apr 2017
Galea VP Laaksonen I Matuszak SJ Connelly JW Muratoglu O Malchau H

Aims

Our first aim was to determine whether there are significant changes in the level of metal ions in the blood at mid-term follow-up, in patients with an Articular Surface Replacement (ASR) arthroplasty. Secondly, we sought to identify risk factors for any increases.

Patients and Methods

The study involved 435 patients who underwent unilateral, metal-on-metal (MoM) hip resurfacing (HRA) or total hip arthroplasty (THA). These patients all had one measurement of the level of metal ions in the blood before seven years had passed post-operatively (early evaluation) and one after seven years had passed post-operatively (mid-term evaluation). Changes in ion levels were tested using a Wilcoxon signed-rank test. We identified subgroups at the highest risk of increase using a multivariable linear logistic regression model.