The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1388 - 1395
1 Oct 2007
Hembree WC Ward BD Furman BD Zura RD Nichols LA Guilak F Olson SA

Post-traumatic arthritis is a frequent consequence of articular fracture. The mechanisms leading to its development after such injuries have not been clearly delineated. A potential contributing factor is decreased viability of the articular chondrocytes. The object of this study was to characterise the regional variation in the viability of chondrocytes following joint trauma. A total of 29 osteochondral fragments from traumatic injuries to joints that could not be used in articular reconstruction were analysed for cell viability using the fluorescence live/dead assay and for apoptosis employing the TUNEL assay, and compared with cadaver control fragments.

Chondrocyte death and apoptosis were significantly greater along the edge of the fracture and in the superficial zone of the osteochondral fragments. The middle and deep zones demonstrated significantly higher viability of the chondrocytes. These findings indicate the presence of both necrotic and apoptotic chondrocytes after joint injury and may provide further insight into the role of chondrocyte death in post-traumatic arthritis.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 425 - 425
1 Apr 2004
Furman BD Lai S Li S
Full Access

Directly molding IB, MG and AGC UHMWPE tibial inserts has provided excellent clinical performance. This performance may be related to the oxidation resistance and higher fracture toughness provided by the direct molding process. Directly molded UHMWPE components have been reported not to oxidize after either nine years post irradiation aging on the shelf or after 11 years of implantation. Retrievals show that molded IB inserts to have lower oxidation, better polyethylene quality and less surface damage than machined IB II inserts. However, the IB, MG and AGC products were directly molded from 1900 UHMWPE resin which is no longer available. The question remains if directly molding resins other than 1900 in a contemporary modular design will provide the same benefits. We report here on the first knee simulation wear of a contemporary total knee system comprised of a directly molded 1020 esin tibial insert. This result will be compared to the knee simulation result of an IBII machined from 4150 extruded ro 4 Optetrak tibial inserts made by directly molding 1020 resin were tested on a 4 station Instron/Stanmore simulator at 1.4 Hz with a 2279 N maximum load and right knee kinematics. The lubricant was bovine calf serum with EDTA and sodium azide. Axial loads were applied from 0 to 40& #778; flexion and internal/external rotation was −3/+6 degrees. Location, type and area of surface damage, were evaluated every 1 million cycles (Mc).

The wear rate of the directly molded inserts was 6X less than reported for machined IB II inserts (2 vs 12 mg/million cycles respectively). There were no signs of delamination or pitting with either design. The more conforming Optetrak provided 52% reduction in wear area over the IB II (21 vs 32 % respectively). This demonstrates that resins other than 1900 may be directly molded in a contemporary and provide the same historical advantages.