header advert
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 181 - 181
1 Jul 2014
Speirs A Frei H Lamontagne M Beaule P
Full Access

Summary

The cartilage layer from cam-type femoroacetabular impingement deformities had lower stiffness and increased permeability compared to normal cartilage. This is consistent with osteoarthritis and supports the hypothesis of abnormal contact stresses.

Introduction

Femoroacetabular impingement (FAI) has recently been associated with osteoarthritic (OA) degeneration of the hip and may be responsible for up to 90% of adult idiopathic OA cases. FAI results from deformities in the hip joint which may lead to abnormal contact stresses and degeneration. The more common cam-type deformity consists of a convex anterior femoral head-neck junction which impinges the anterosuperior acetabular rim during flexion and internal rotation of the hip. Increased subchondral bone density has been reported in this region which may be a bone remodelling response to increased contact stress. The abnormal contact is expected to cause degeneration of the cartilage layer. The goal of this study was to assess the mechanical properties of cartilage retrieved from the cam deformity and to compare this with normal articular cartilage from the femoral head. It is hypothesised that the cartilage will have a lower elastic modulus and higher permeability than normal cartilage.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 962 - 970
1 Jul 2007
Albert C Patil S Frei H Masri B Duncan C Oxland T Fernlund G

This study explored the relationship between the initial stability of the femoral component and penetration of cement into the graft bed following impaction allografting.

Impaction allografting was carried out in human cadaveric femurs. In one group the cement was pressurised conventionally but in the other it was not pressurised. Migration and micromotion of the implant were measured under simulated walking loads. The specimens were then cross-sectioned and penetration of the cement measured.

Around the distal half of the implant we found approximately 70% and 40% of contact of the cement with the endosteum in the pressure and no-pressure groups, respectively. The distal migration/micromotion, and valgus/varus migration were significantly higher in the no-pressure group than in that subjected to pressure. These motion components correlated negatively with the mean area of cement and its contact with the endosteum.

The presence of cement at the endosteum appears to play an important role in the initial stability of the implant following impaction allografting.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 5 | Pages 771 - 776
1 Jul 2004
Frei H Mitchell P Masri BA Duncan CP Oxland TR

We studied various aspects of graft impaction and penetration of cement in an experimental model. Cancellous bone was removed proximally and local diaphyseal lytic defects were simulated in six human cadaver femora. After impaction grafting the specimens were sectioned and prepared for histomorphometric analysis.

The porosity of the graft was lowest in Gruen zone 4 (52%) and highest in Gruen zone 1 (76%). At the levels of Gruen zones 6 and 2 the entire cross-section was almost filled with cement. Cement sometimes reached the endosteal surface in other Gruen zones. The mean peak impaction forces exerted with the impactors were negatively correlated with the porosity of the graft.