header advert
Results 21 - 29 of 29
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 2 | Pages 242 - 248
1 Mar 1985
Bertin K Freeman M Samuelson K Ratcliffe S Todd R

Fifty-three failed knee replacements were revised using minimally constrained implants with smooth uncemented intramedullary stems and metal-backed tibial components. Polymethylmethacrylate was used only to replace lost bone near the surface of the implant. Excluding four knees which had serious postoperative complications, 91% had successful relief of pain, 84% had over 90 degrees of movement and 80% could walk for more than 30 minutes. Review of the radiographs showed that there were no progressive lucencies at the interface between bone and cement, and no subsidence of components or changes in alignment. At the uncemented stem-to-bone interface, thin white lines developed near the metal, and their significance is discussed. This revision technique is an effective treatment for aseptic failure of primary total knee arthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 4 | Pages 405 - 411
1 Aug 1983
Freeman M Bradley G

Clinical experience of the ICLH method of resurfacing the hip now spans 10 years. The first 36 arthroplasties, performed between 1972 and 1974, have been previously reported. This review covers in detail 204 such arthroplasties performed between 1975 and 1979 using a standard operative technique and prosthesis; these hips were consecutive and entirely unselected. Follow-up averaged 3.2 years (range two to six years). Successful hips are comparable to hips successfully replaced with stemmed prostheses. The rates of perioperative complications and failure due to infection, ectopic ossification, fracture of the femoral neck, and dislocation are favourably comparable to rates reported for stemmed total hip arthroplasties. The rate of aseptic loosening (17 per cent) greatly exceeded that found for stemmed total hip arthroplasties. Errors of patient selection, operative technique and prosthetic design have been identified. It is concluded that, although resurfacing arthroplasty of the hip may be an appealing procedure with theoretical advantages in certain instances, patient selection is essential, operative technique is demanding and changes in the design of the prosthesis are required. The procedure is still in evolution and therefore it should not yet be generally employed.


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 4 | Pages 448 - 451
1 Aug 1983
Levai J McLeod H Freeman M

The results of resurfacing or not resurfacing the articular cartilage of the patella were reviewed in 71 knees--47 with rheumatoid arthritis and 24 with osteoarthritis--which had been replaced with the ICLH prosthesis. Two rheumatoid and osteoporotic patellae developed transverse fractures with separation and were excluded from the review. The results showed that resurfacing the patella greatly reduced peripatellar pain with no counter-balancing disadvantage.


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 4 | Pages 489 - 493
1 Aug 1982
Freeman M Bradley G Revell P

The occurrence of a radiolucent line at the interface of bone and cement in total joint prostheses is a frequently observed, although little understood, phenomenon. Because of an operative technique utilised in instances of bone loss, we have, within a single implant mass used in each of a series of 18 total knee replacements, been able to observe two separate interfaces, one between bone and cement and the other between bone and cobalt chrome. The average period of observation was 32 months. All of the knees except one demonstrated a lucency at the bone-cement interface; only one of the knees had a similar lucency at the bone-CoCr interface. One of the knees was studied histologically. In the light of the universal observation of macrophages at bone-cement interfaces and the recent finding that osteoclasts are derived from macrophages, these observations are significant in relation to the aetiology of bone-cement lucencies.


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 3 | Pages 326 - 335
1 Jun 1982
Blaha J Insler H Freeman M Revell P Todd R


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 3 | Pages 339 - 344
1 Aug 1978
Freeman M Todd R Bamert P Day W

The essentially satisfactory results from the ICLH implant as used until 1975 were marred by examples of loosening and sinking of the tibial implant, by patellar pain of varying severity, by wear of the tibial implant caused by fragments of cement and by failure consistently to control the alignment of the leg. This report describes the methods now being used to overcome these complications and gives an account of the success so far achieved.


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 2 | Pages 256 - 261
1 May 1978
Bargren J Day W Freeman M Swanson S

Cadaveric knees replaced with the Geomedic, ICLH, Marmor and Total Condylar prostheses were tested in axial compression, in rotation and in hyperextension in order to observe the strength of fixation of the tibial components. In axial compression the strengths at failure varied widely, both with any one prosthesis and between prostheses. This is attributed largely to the strength of the cancellous bone of the tibia, which was measured in each case and also varied widely. Three natural knees failed at loads of 7300, 7600 and 8300 newtons respectively, whereas the strengths of replaced knees ranged from 3000 to 15750 newtons. At least one example of each design failed at less than 7300 newtons, suggesting little or no reserve of strength. The strength of fixation was greater when the tibial prosthesis was large enough to rest on the whole cross-section of the tibia. In rotation the three prostheses embodying rollers in troughs were stiffer than the Marmor which had a nearly flat tibial-bearing surface. The presence or absence of the cruciate ligaments had a negligible effect on torsional stiffness. In hyperextension, knees replaced with the ICLH, Marmor and Total Condylar prostheses failed by rupture of the posterior capsule at moments of about 60 newton-metres, compared with about 100 for natural knees. With the Marmor prosthesis the anterior cruciate ligament was avulsed at about 20 newton-metres compared with about 75 in natural knees, suggesting that in this respect the retention of the cruciate ligaments contributes little. None of the four knees tested after inserting a Geomedic prosthesis showed strengths as high as those replaced with the other three designs.


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 1 | Pages 64 - 71
1 Feb 1977
Freeman M Sculco T Todd R

A multi-centre clinical trial of ICLH (Freeman-Swanson) arthroplasty has been in progress since 1971. In this paper the results up to two years after operation are reported in seventy-one knees displaying at least 30 degrees of fixed flexion, 25 degrees of valgus or 20 degrees of varus, before operation. It has been found that knees displaying 70 degrees of fixed flexion, 70 degrees of valgus, 30 degrees of varus or 50 degrees of valgus/varus instability can be satisfactorily aligned and stabilised with acceptable function. Three knees required revision. The other complications are listed and were unremarkable in nature. These results depend upon the prosthesis and upon the operative technique. The latter avoids damage to healthy bone but does involve the replacement of the tissues in the midline of the knee.


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 4 | Pages 453 - 461
1 Nov 1976
Inoue A Freeman M Vernon-Roberts B Mizuno S

It has been shown that in the puppy, two infarcts separated by an interval of four weeks produce a disorder of long duration which results in flattening and broadening of the femoral head and which reproduces the radiological changes seen in Perthes' disease in man. The histological appearances produced by two infarcts are characteristic. In this study the histological appearance of fifty-seven femoral head biopsy specimens in Perthes' disease in man have been studied. In 51 per cent of hips histopathological changes characteristic of double infarction were present, and there were grounds for postulating that double infarction might eventually occur in all cases. The findings support the concept that the deformation of the femoral head and the chronicity of Perthes' disease in man may be due at least as much or even more to repeated episodes of infarction and the ensuing abnormalities of growth as to mechanical factors related to weight-bearing.