header advert
Results 1 - 7 of 7
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 34 - 34
23 Apr 2024
Duguid A Ankers T Narayan B Fischer B Giotakis N Harrison W
Full Access

Introduction

Charcot neuroarthropathy is a limb threatening condition and the optimal surgical strategy for limb salvage in gross foot deformity remains unclear. We present our experience of using fine wire frames to correct severe midfoot deformity, followed by internal beaming to maintain the correction.

Materials and Methods

Nine patients underwent this treatment between 2020–2023. Initial deformity correction by Ilizarov or hexapod butt frame was followed by internal beaming with a mean follow up of 11 months. A retrospective analysis of radiographs and electronic records was performed. Meary's angle, calcaneal pitch, cuboid height, hindfoot midfoot angle and AP Meary's angle were compared throughout treatment. Complications, length of stay and the number of operations are also described.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 47 - 47
1 Apr 2022
Myatt D Stringer H Mason L Fischer B
Full Access

Introduction

Diaphyseal tibial fractures account for approximately 1.9% of adult fractures. Several studies demonstrate a high proportion of diaphyseal tibial fractures have ipsilateral occult posterior malleolus fractures, this ranges from 22–92.3%.

Materials and Methods

A retrospective review of a prospectively collected database was performed at Liverpool University Hospitals NHS Foundation Trust between 1/1/2013 and 9/11/2020. The inclusion criteria were patients over 16, with a diaphyseal tibial fracture and who underwent a CT. The articular fracture extension was categorised into either posterior malleolar (PM) or other fracture


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 48 - 48
1 Apr 2022
Myatt D Stringer H Mason L Fischer B
Full Access

Introduction

Diaphyseal tibial fractures account for approximately 1.9% of adult fractures. Studies have demonstrated a high proportion have ipsilateral occult posterior malleolus fractures. We hypothesize that this rotational element will be highlighted using the Mason & Molloy Classification.

Materials and Methods

A retrospective review of a prospectively collected database was performed at Liverpool University Hospitals NHS Foundation Trust between 1/1/2013 and 9/11/2020. The inclusion criteria were patients over 16, with a diaphyseal tibial fracture, who underwent a CT. The Mason and Molloy posterior malleolus fracture classification system was used.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 15 - 15
1 May 2021
Debuka E Peterson N Fischer B Birkenhead P Narayan B Giotakis N Thorpe P Graham S
Full Access

Introduction

Methoxyflurane can cause hepatotoxicity and nephrotoxicity at anaesthetic doses but has excellent analgesic properties and no nephrotoxic effects in patients without preexisting disease. Approved for use in the UK and Ireland in 2015, it is currently being used in emergency departments for analgesia during fracture reduction. During the Covid emergency, with theatre access severely restricted and many patients unwilling to use inhaled Nitrous oxide, Penthrox had the potential to provide adequate pain relief to aid frame removals and minor procedures in the clinic.

Materials and Methods

Patients presenting to the Limb Reconstruction Unit Elective clinic and requiring frame removal or minor procedures were included in the study. Patients with renal, cardiac or hepatic disease, history of sensitivity to fluorinated anaesthetic agents and those on any nephrotoxic or enzyme inducing drugs were excluded. Verbal consent was obtained, the risks and benefits explained and the procedure was done in a side room in the clinic. Besides patient and procedure details, the Visual Analog Score and Richmond Agitation Scale was noted and patient's satisfaction documented. The results were presented as numbers, means and averages.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 44 - 44
1 May 2018
Lotfi N Thangarj R Fischer B Fenton P
Full Access

Introduction

Fractures of the distal tibia can be challenging to manage. Numerous surgical techniques have been utilised in managing these however there remains debate as to the optimum method of fixation. This study aims to assess the surgical outcomes and PROMs of patients with distal tibial fractures managed with intramedullary-nails or ring fixation.

Methods

This is a retrospective study of patients with closed distal tibial fractures managed between 01/01/2013–31/12/2016. Adult patients admitted with closed fracture of the distal tibia fixed with an intramedullary-nail or circular-frame were included in the study. Primary outcomes were time of union, alignment of tibia post-operatively and the results of two validated PROMs (Kujala knee score and Olerud and Molander Ankle Score).


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 27 - 27
1 May 2018
Bridgeman P Raven M Fischer B Bose D Fawdington R Fenton P
Full Access

Background

Many patients undergo frame removal in the outpatient setting and nitrous oxide is frequently used, but has varying effects. The aim of the study was to ascertain whether pain levels during frame removal are improved with local infiltration of local anaesthetic (LA) and to assess the effect of LA and nitrous oxide compared to nitrous oxide alone.

Methodology

This was a small single centre study using patient reported questions to assess pain levels during frame removal. The test group received 5–20ml 2% lidocaine infiltrated into tissues surrounding half pins and olive wire exit sites. All patients were asked to complete a questionnaire to assess pain levels and patient satisfaction following the procedure. Patients were asked to mark their pain level on a 100mm visual analogue scale giving a final pain score out of 100.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXII | Pages 29 - 29
1 May 2012
Roche A Bennett S Fischer B Molloy A
Full Access

NHS governance demands that services provided are clinically effective and safe. In the current financial climate and threats over public sector spending cuts, services offered by health care providers should also be cost-effective and profitable. Surgical specialties are often perceived as expensive with high implant costs. The aim of this audit was to cost the profit margin for foot/ankle surgery and test the accuracy of coding data collected.

Materials and Methods

Theatre data between January-April 2010 was retrospectively reviewed. Equipment inventories, operation notes and radiographs were reviewed for implants used. Clinical coding data was analysed and coded separately by the surgeon for comparison. Theatre expenses were calculated and accuracy estimated. Tariff generated and patient expenses were calculated and a final profit margin revealed. Wilcoxon matched-pair testing compared hospital recorded and surgeon calculated data.

Results

95 cases were included (51 forefoot, 5 midfoot, 6 arthroscopy, 12 hindfoot, 21 other), 65 female and 30 male patients. Theatre inventories were correct in 11% of cases. Mean inventory costs recorded were £90 and following surgeon analysis, £319. Total actual inventory cost was £30,306.23 but £8548.58 was recorded (p<0.0001). OPCS codes were deemed correct in 43% and incorrect in 57% of cases. Operation profit margin, including theatre, ward and salary costs was recorded as £158,229 but corrected profit margin with d inventories and OPCS codes was £121,584 (p=0.001).