header advert
Results 1 - 3 of 3
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 5 | Pages 745 - 748
1 Sep 1992
Fern E Winson I Getty C

Postoperative anterior knee pain was evaluated in a consecutive series of 138 knees in 108 patients with rheumatoid arthritis treated by total knee replacement with Mark I Insall-Burstein prostheses. No knee had primary patellar resurfacing, and in the 119 knees followed up for a mean of 63.9 months, none had secondary resurfacing. Anterior knee pain was absent in 87 knees (73%), mild in 16 (13.5%) and moderate or severe in 16 (13.5%). The height of the patella above the prosthetic joint line was the only variable which was directly related to the incidence of anterior knee pain. The sensitivity and specificity of patellar height measurements for identifying patients with or without pain were derived. From these data, a selective policy of resurfacing the patella in those at risk was adopted. Choosing a patellar height of 15 mm or less, patellar resurfacing could be avoided in 80% of patients likely to have no pain, and the patella could be resurfaced in 65% of those likely to have anterior knee pain.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 6 | Pages 1073 - 1075
1 Nov 1990
Fern E Stockley I Bell M

Five patients with Boyd type II congenital pseudarthrosis of the tibia underwent excision of the pseudarthrosis and double onlay bone grafting. Stability was maintained by extending intramedullary rods. Clinical union was achieved in all cases at a mean of 8.6 months (range six to 11). The rods extended by 15.7% (range 2% to 31.4%) as growth occurred. One rod was removed because of infection and a vascularised free fibular graft was subsequently performed. The extending rods provided stability while union occurred and did not require revision as the legs grew. The rods can be removed easily and have not jeopardized further surgical options.


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 4 | Pages 588 - 590
1 Aug 1989
Fern E Stewart H Newton G

We report the use of long curved Kuntscher nails to maintain stability during arthrodesis of nine infected and five uninfected failures of total knee replacement. The curvature of the nail helps positioning and avoids the need for cortical perforation. A single-stage operation was possible in most cases. Union rates are comparable with those of other series and even patients with delayed union have satisfactory function.