header advert
Results 1 - 2 of 2
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1405 - 1411
3 Oct 2020
Martynov I Klink T Slowik V Stich R Zimmermann P Engel C Lacher M Boehm R

Aims

This exploratory randomized controlled trial (RCT) aimed to determine the splint-related outcomes when using the novel biodegradable wood-composite splint (Woodcast) compared to standard synthetic fibreglass (Dynacast) for the immobilization of undisplaced upper limb fractures in children.

Methods

An exploratory RCT was performed at a tertiary paediatric referral hospital between 1 June 2018 and 30 September 2019. The intention-to-treat population consisted of 170 patients (mean age 8.42 years (SD 3.42); Woodcast (WCG), n = 84, 57 male (67.9%); Dynacast (DNG), n = 86, 58 male (67.4%)). Patients with undisplaced upper limb fractures were randomly assigned to WCG or DNG treatment groups. Primary outcome was the stress stability of the splint material, defined as absence of any deformations or fractures within the splint during study period. Secondary outcomes included patient satisfaction and medical staff opinion. Additionally, biomechanical and chemical analysis of the splint samples was carried out.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 171 - 171
1 Mar 2008
Kessler O Lacatusu E Erne OV Zandschulp C Engel C Spriggins A Bottlang M
Full Access

This study investigated the difference in proximal tibial cortical strain distribution using a fixed or mobile bearing design for TKA.

Eight fresh frozen human cadaver tibias were used. The strain magnitude and distribution on the anterior cortex of the proximal tibia during axial and rotational loading of the knee were measured with a quantitative full-field strain measurement technique (Electronic Speckle Pattern Interferometry). First, strain distributions of the intact knee were acquired. Subsequently, strain distributions after implantation of conventional and mobile bearing PCL retaining total knee implants (Scorpio®) were measured

Under each loading condition, the minimum principal strain was greater in magnitude as compared to the maximum principal strain. Under 1,500 N axial loading, the resulting minimum principal strain magnitude and orientation was nearly identical between the mobile bearing configuration(500 ± 287m;e;), and the fixed bearing configuration (500 ± 286m;e;). In response to 10° internal rotation, this strain increased to 782 ± 371m;e; and 1000± 389m;e; for the mobile and fixed tibial component, respectively. In 10° external rotation, minimal principal strain decreased to 421 ± 233m;e; for the mobile bearing, but increased to 632 ± 293m;e; for the fixed bearing. These differences between mobile and fixed bearing scenarios were highly statistically significant.

For this in-vitro study under exact controlled loading conditions the mobile bearing design induced less strain in the proximal tibia than the fixed bearing tibial component. The difference in strain levels may be of importance for bone remodeling and osseointegration.