header advert
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 34 - 34
1 Dec 2017
El Sayed F Gruber A Sapriel G Fawal N Bauer T Heym B Dupont C Hello SL Gaillard J Rottman M
Full Access

Aim

According to Tsukuyama classification, late acute hematogenous prosthesis joint infections (PJI) should be treated with debridement and implant retention (DAIR). We report here a recurrent Salmonella Dublin hip prosthesis infection. Through this case, we show how a recurrence of chronic PJI may have an acute clinical presentation leading to an inadequate surgical treatment.

Method

Case report. On May 2011, a 74-year-old woman with bilateral hip prostheses (implanted in 1998 (right) and 2001 (left)), was admitted to intensive care for sepsis and pain of her left hip. Blood cultures and a joint aspiration of the left hip yielded pure cultures of S.Dublin. The patient had a recent history of febrile diarrhea after consuming dubious meat. The patient underwent DAIR followed by a six-week antibiotherapy. Three years later, she presented to the emergency room for an acute onset febrile PJI of the right hip. The patient underwent DAIR of the right hip. Blood cultures, joint aspiration fluid, and all intraoperative periprosthetic tissue samples yielded S.Dublin. Colonoscopy and abdomen ultrasound were negative. The patient received two weeks of intravenous combined antibiotherapy followed by oral antibiotics for further 10 weeks. Six weeks post operatively, the surgical wound was healed and the patient walked normally. One year later, the patient was referred by her primary care practitioner for night fevers without local signs or dysfunction of her prostheses. Radioleucoscintigraphy showed right hip inflammation. Bilateral hip biopsies were nevertheless performed, yet S. Dublin was recovered solely from the right hip biopsy. A one-stage exchange of the right hip was performed. All intraoperative periprosthetic tissue samples yielded S.Dublin. A six-week-combined antibiotherapy was undertaken. One year later, the patient appeared free of infection and walked normally.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 441 - 448
1 Apr 2007
Vendittoli P Mottard S Roy AG Dupont C Lavigne M

We evaluated the concentrations of chromium and cobalt ions in blood after metal-on-metal surface replacement arthroplasty using a wrought-forged, high carbon content chromium-cobalt alloy implant in 64 patients. At one year, mean whole blood ion levels were 1.61 μg/L (0.4 to 5.5) for chromium and 0.67 μg/L (0.23 to 2.09) for cobalt. The pre-operative ion levels, component size, female gender and the inclination of the acetabular component were inversely proportional to the values of chromium and/or cobalt ions at one year postoperatively. Other factors, such as age and level of activity, did not correlate with the levels of metal ions. We found that the levels of the ions in the serum were 1.39 and 1.37 times higher for chromium and cobalt respectively than those in the whole blood.

The levels of metal ions obtained may be specific to the hip resurfacing implant and reflect its manufacturing process.