header advert
Results 1 - 5 of 5
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 41 - 41
1 Mar 2021
Pontremoli C Berkmann JC Martin AXH Ellinghaus A Schmidt-Bleek O Laurano R Boffito M Turo CT Schmidt-Bleek K Duda GN Fiorilli S Brovarone CV
Full Access

Mesoporous bioactive glasses (MBGs) have been widely studied as bone regeneration systems, due to their bioactivity and ability to store and release therapeutic agents with specific biological functions. The incorporation of these nanomaterials into a thermosensitive hydrogel (TSH), in which a solution undergoes a sol-gel transition under physiological conditions, represents a promising approach to design multifunctional devices able to deliver selected molecules to pathological sites. In fact, this system can perfectly fit the defect cavity shape prior to the complete gelation, and acts as a carrier for therapeutic agents prolonged release in situ. This challenging concept is the underlying idea of the MOZART project, whose objective was to develop a library of MBGs containing different therapeutic ions and drugs, to be used as a new, smart platform technology for highly targeted therapies to enhance bone healing. The aim of this work is to investigate the bone regeneration potential of MBGs containing strontium ions (pro-osteogenic) and incorporated into thermosensitive poly(etherurethane)(PEU) based on Poloxamer407. In order to further increase the pro-osteogenic response, MBGs were also loaded with N-acetylcysteine (NAC).

MBGs containing 2%mol of Sr2+ were prepared by an aerosol-assisted spray-drying method and NAC was loaded post-synthesis via an incipient wetness method. The PEU hydrogel (SHP407) was synthesized via a two-step procedure in nitrogen atmosphere. Particles were characterized (FE-SEM, N2 adsorption-desorption analysis, TGA, DSC, FT-IR and XRD) and then incorporated into the hydrogel. The hybrid systems rheological properties and stability in aqueous environment at 37°C, and its ability to co-release Sr2+ and NAC were analysed. After preliminary biological in vitro tests, a proof-of-concept rodent study was run to assess the ability of the resulting formulation as bone healing device. X-ray at 2 and 4-weeks post-surgery and µCT-analysis were used to evaluate the healing results in a rat osteotomy model of biologically impaired healing. Then, bones were processed for histological evaluation.

Preliminary in vivo results demonstrated that incorporation of MBGs into a TSH is a promising strategy to design a multifunctional injectable formulation for in situ and sustained delivery of pro-osteogenic species enhancing bone regeneration.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 13 - 13
1 Jul 2020
Wildeman B Bormann N Beuttel E Pobloth A Duda GN
Full Access

Despite the increasing availability of bone grafting materials, the regeneration of large bone defects remains a challenge. Especially infection prevention while fostering regeneration is a crucial issue. Therefore, loading of grafting material with antibiotics for direct delivery to the site of need is desired. This study evaluates the concept of local delivery using in vitro and in vivo investigations. We aim at verifying safety and reliability of a perioperative enrichment procedure of demineralized bone matrix (DBM) with gentamicin.

DBM (DBMputty, DIZG, Germany) was mixed with antibiotic using a syringe with an integrated mixing propeller (Medmix Systems, Switzerland). Gentamicin, as powder or solution, was mixed with DBM at different concentrations (25 −100 mg/g DBM), release and cytotoxicity was analyzed. For in vivo analysis, sterile drill hole defects (diameter: 6 mm, depth: 15 mm) were created in diaphyseal and metaphyseal bones of sheep (Pobloth et al. 2016). Defects (6 – 8 per group and time point) were filled with DBM or DBM enriched with gentamicin (50 mg/g DBM) or left untreated. After three and nine weeks, defect regeneration was analyzed by µCT and histology.

The release experiments revealed a burst release of gentamicin from DBM independent of the used amount, the sampling strategy, or the formulation (powder or solution). Gentamicin was almost completely released after three days in all set-ups. Eluates showed an antimicrobial activity against S. aureus over at least three days. Eluates had no negative effect on viability and alkaline phosphatase activity of osteoblast-like cells (partially published Bormann et al. 2014). µCT and histology of the drill hole defects revealed a reduced bone formation with gentamicin loaded DBM. After nine weeks significantly less mineralized tissue was detectable in metaphyseal defects of the gentamicin group. Histological evaluation revealed new bone formation starting at the edges of the drill holes and growing into the center over time. The amount of DBM decreased over time due to the active removal by osteoclasts while osteoblasts formed new bone.

Using this mixing procedure, loading of DBM was fast, reliable and possible during surgical setting. In vitro experiments revealed a burst and almost complete release after three days, antimicrobial activity and good biocompatibility of the eluates. Gentamicin/DBM concentration was in the range of clinically used antibiotic-loaded-cement for prophylaxis and treatment in joint replacement (Jiranek et al. 2006). The delayed healing seen in vivo was unexpected due to the good biocompatibility found in vitro. A reduced healing was also seen in spinal fusion where DBM was mixed with vancomycin (Shields et al. 2017), whereas DBM with gentamicin or DBM/bioactive glass with tobramycin had no negative effect on osteoinductivity or femur defect healing, respectively (Lewis et al. 2010, Shields et al. 2016). In conclusion, loading of DBM with gentamicin showed a proper antibiotic delivery over several days, covering the critical phase shortly after surgery. Due to the faster and complete release of the antibiotic compared to antibiotic loaded cement, the amount of antibiotic should be much lower in the DBM compared to cement.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 40 - 40
1 Nov 2018
Berkmann JC Qazi TH Hafeez S Schmidt J Schoon J Geissler S Duda GN Boccaccini AR Lippens E
Full Access

Promising work on bioactive glasses (BAGs) in bone defect regeneration has led to their clinical implementation. However, the effects of the ionic dissolution products of different types and the physical interaction modalities of BAGs on the behavior and function of mesenchymal stromal cells (MSCs) of human patients have not received sufficient attention. Recently, we showed that the in vitro response of hMSC to micron-sized, monodispersed BAGs is dependent on dosage, composition, and mode of interaction1. Two commercially available and widely used types of BAGs, namely the silicate BAGs 45S5 and 1393, were used to study hMSC cell behavior. Interestingly, exposure to 1393 BAG resulted in superior metabolic activity, proliferation, and cell spreading compared to 45S5 BAG in similar dosage, suggesting that additional cellular functions could also be differentially modulated by both glasses1. In the context of bone regeneration, the hMSCs’ potential to secrete angiogenic factors as well as deposit mineralized matrix upon exposure to BAG dissolution products was investigated in the present study. Aside from dose-dependent effects of both glasses, 45S5 BAG induced a significant pro-angiogenic response, demonstrated by robust tube formation in HUVECs in the presence of MSC conditioned media. 1393 BAG, on the other hand, stimulated osteogenesis by upregulating osteogenic gene expression and mineralized matrix deposition. Based on these results, combining the pro-angiogenic 45S5 BAG and the pro-osteogenic 1393 BAG might be an attractive strategy to target the multiple processes underlying bone regeneration. These results highlight how different BAGs can be utilized to promote MSC-mediated bone regeneration.


Bone & Joint Research
Vol. 7, Issue 3 | Pages 232 - 243
1 Mar 2018
Winkler T Sass FA Duda GN Schmidt-Bleek K

Despite its intrinsic ability to regenerate form and function after injury, bone tissue can be challenged by a multitude of pathological conditions. While innovative approaches have helped to unravel the cascades of bone healing, this knowledge has so far not improved the clinical outcomes of bone defect treatment. Recent findings have allowed us to gain in-depth knowledge about the physiological conditions and biological principles of bone regeneration. Now it is time to transfer the lessons learned from bone healing to the challenging scenarios in defects and employ innovative technologies to enable biomaterial-based strategies for bone defect healing. This review aims to provide an overview on endogenous cascades of bone material formation and how these are transferred to new perspectives in biomaterial-driven approaches in bone regeneration.

Cite this article: T. Winkler, F. A. Sass, G. N. Duda, K. Schmidt-Bleek. A review of biomaterials in bone defect healing, remaining shortcomings and future opportunities for bone tissue engineering: The unsolved challenge. Bone Joint Res 2018;7:232–243. DOI: 10.1302/2046-3758.73.BJR-2017-0270.R1.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_5 | Pages 57 - 57
1 Feb 2016
Ehlke M Heyland M Mardian S Duda GN Zachow S
Full Access

We present a novel method to derive the surface distance of an osteosynthesis plate w.r.t. the patient-specific surface of the distal femur based on 2D X-ray images. Our goal is to study from clinical data, how the plate-to-bone distance affects bone healing. The patient-specific 3D shape of the femur is, however, seldom recorded for cases of femoral osteosynthesis since this typically requires Computed Tomography (CT), which comes at high cost and radiation dose. Our method instead utilises two postoperative X-ray images to derive the femoral shape and thus can be applied on radiographs that are taken in clinical routine for follow-up. First, the implant geometry is used as a calibration object to relate the implant and the individual X-ray images spatially in a virtual X-ray setup. In a second step, the patient-specific femoral shape and pose are reconstructed in the virtual setup by fitting a deformable statistical shape and intensity model (SSIM) to the images. The relative positioning between femur and implant is then assessed in terms of displacement between the reconstructed 3D shape of the femur and the plate. A preliminary evaluation based on 4 cadaver datasets shows that the method derives the plate-to-bone distance with a mean absolute error of less than 1mm and a maximum error of 4.7 mm compared to ground truth from CT. We believe that the approach presented in this paper constitutes a meaningful tool to elucidate the effect of implant positioning on fracture healing.