header advert
Results 1 - 20 of 28
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 94 - 94
2 Jan 2024
Graça A Domingues R Docheva D Gomez-Florit M Gomes M
Full Access

Worldwide, tendon disorders are one of the main causes of disability that decrease the quality of life of individuals and represent a substantial economic burden on society. Currently, the main therapies used for tendon injuries are not able to restore tendon functionality, and due to tendons' hypovascular and hypocellular nature, they present a reduced healing capacity, which also limits the success of the available therapies. In order to discover new therapies, extracellular vesicles (EVs), key players in cell-cell communication, have been widely explored for tissue engineering and regenerative medicine applications. Thus, the aim of this study is to assess the role of EVs derived from platelets in stem cell tenogenic commitment using a bioengineered tendon in vitro model for potential use as tendon therapeutic agents. Biomimetic platelet-derived EVs were produced by freeze-thaw cycles of platelets and isolation at different centrifugation speed. To recreate the architecture of tendons, a 3D system consisting of electrospun anisotropic nanofiber scaffolds coated with collagen encapsulating human adipose stem cells (hASCs) and different types of platelet-derived EVs, were produced. Then, the influence of the tendon-mimetic constructs and the distinct EVs populations in the hASCs tenogenic differentiation were assessed over culture time. We observed that the hASCs on the nanofibrous tendon scaffolds, show high cytoskeleton anisotropic organization that is characteristic of tenocytes. Moreover, acting as biological cues, platelet-derived EVs boosted hASCs tenogenic commitment, supported by the increased gene expression of tendon-related markers (SCX and TNMD). Additionally, EVs enhanced the deposition of tendon like extracellular matrix (ECM), as evidenced by the increased gene expression of ECM-related markers such as COL1, COL3, DCN, TNC, and MMP-3, which are fundamental for ECM synthesis and degradation balance. Moreover, EVs induced lower collagen matrix contraction on hASCs, which has been related with lower myofibroblast differentiation. Overall, the results revealed that EVs are capable of modulating stem cells' behavior boosting their tenogenic commitment, through the increased expression of healthy tendon cell markers, potentiating ECM deposition and decreasing cell contractility. Therefore, platelet EVs are a promising biochemical tool, worthy to be further explored, as paracrine signaling that might potentiate tendon repair and regeneration.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 81 - 81
17 Apr 2023
Rambacher K Gennrich J Schewior R Lang S Pattappa G Zihlmann C Stiefel N Zellner J Docheva D Angele P
Full Access

Meniscus tears have been treated using partial meniscectomy to relieve pain in patients, although this leads to the onset of early osteoarthritis (OA). Cell-based therapies can help preserve the meniscus, although the presence of inflammatory cytokines compromises clinical outcomes. Anti-inflammatory drugs (e.g. celecoxib), can help to reduce pain in patients and in vitro studies suggest a beneficial effect on cytokine inhibited matrix content. Previously, we have demonstrated that the inhibitory effects of IL-1β can be countered by culture under low oxygen tension or physioxia. The present study sought to understand whether physioxia, celecoxib or combined application can counter the inhibitory effects IL-1β inhibited meniscus cells.

Human avascular and vascular meniscus cells (n =3) were isolated and expanded under 20% (hyperoxia) or 2% (physioxia) oxygen. Cells were seeded into collagen scaffolds (Geistlich, Wolhusen) and cultured for 28 days either in the presence of 0.1ng/mL IL-1β, 5µg/mL celecoxib or both under their expansion oxygen conditions. Histological (DMMB, collagen I and collagen II immunostaining), GAG content and gene expression analysis was evaluated for the scaffolds.

Under hyperoxia, meniscus cells showed a significant reduction in GAG content in the presence of IL-1β (*p < 0.05). Celecoxib alone did not significantly increase GAG content in IL-1β treated cultures. In contrast, physioxic culture showed a donor dependent increase in GAG content in control, IL-1β and celecoxib treated cultures with corresponding histological staining correlating with these results. Additionally, gene expression showed an upregulation in COL1A1, COL2A1 and ACAN and a downregulation in MMP13 and ADAMTS5 under physioxia for all experimental groups.

Physioxia alone had a stronger effect in countering the inhibitory effects of IL-1β treated meniscus cells than celecoxib under hyperoxia. Preconditioning meniscus cells under physioxia prior to implantation has the potential to improve clinical outcomes for cell-based therapies of the meniscus.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 79 - 79
17 Apr 2023
Stockmann A Grammens J Lenz J Pattappa G von Haver A Docheva D Zellner J Verdonk P Angele P
Full Access

Partial meniscectomy patients have a greater likelihood for the development of early osteoarthritis (OA). To prevent the onset of early OA, patient-specific treatment algorithms need to be created that predict patient risk to early OA after meniscectomy. The aim of this work was to identify patient-specific risk factors in partial meniscectomy patients that could potentially lead to early OA.

Partial meniscectomy patients operated between 01/2017 and 12/2019 were evaluated in the study (n=317). Exclusion criteria were other pathologies or surgeries for the evaluated knee and meniscus (n = 114). Following informed consent, an online questionnaire containing demographics and the “Knee Injury and Osteoarthritis Outcome Score” (KOOS) questionnaire was sent to the patient. Based on the KOOS pain score, patients were classified into “low” (> 75) and “high” (< 75) risk patients, indicating risk to symptomatic OA. The “high risk” patients also underwent a follow-up including an MRI scan to understand whether they have developed early OA.

From 203 participants, 96 patients responded to the questionnaire (116 did not respond) with 61 patients considered “low-risk” and 35 “high-risk” patients. Groups that showed a significant increased risk for OA were patients aged > 40 years, females, overweight (BMI >25 kg/m2 ≤ 30 kg/m2), and smokers (*p < 0.05). The “high-risk”-follow-up revealed a progression of early osteoarthritic cartilage changes in seven patients, with the remaining nineteen patients showing no changes in cartilage status or pain since time of operation. Additionally, eighteen patients in the high-risk group showed a varus or valgus axis deviation.

Patient-specific factors for worse postoperative outcomes after partial meniscectomy and indicators for an “early OA” development were identified, providing the basis for a patient-specific treatment approach. Further analysis in a multicentre study and computational analysis of MRI scans is ongoing to develop a patient-specific treatment algorithm for meniscectomy patients.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 72 - 72
11 Apr 2023
Stich T Kovářík T Křenek T Alt V Docheva D
Full Access

The goal was to analyze the cellular response, specifically the osteogenic capacity, of titanium (Ti) implants harbouring a novel laserbased-surface-structure with the overall aim: augmented osteointegration. Surface micro-/nanoproperties greatly influence cell behaviour at the tissue-implant-interface and subsequent osteointegration. We investigated Ti-materials subjected to a specially developed shifted-Laser-Surface-Texturing (sLST) technology and compared them to a standard roughening-technique (sand-blasting-acid-etching, SLA). The biological response was evaluated with hMSCs, which are naturally available at the bone-implant-interface. We hypothesized: the novel surface is beneficial for our three different (young/healthy-YH; aged/healthy-AH;aged/osteoporotic-OP) cohorts.

The sLST was performed using a SPI-G3-series laser (beam-wavelength=1064nm, pulse-duration=200ns). For the SLA surface, Ti was sandblasted, afterwards acid-etched (HCl/H2SO4). Three different hMSC cohorts were studied: YH: n=6,29±6; AH: n=5,79±5; OP: n=5,76±5 years (osteoporosis confirmed via DEXA-scan). OP hMSCs show e.g. ColI-deficient-matrix and decreased mineralization. Cells were examined for survival, cell proliferation and cytoskeleton arrangement. Osteogenic differentiation was carried out over 21 days, matrix mineralization was validated with Alizarin-Red-S-staining and quantification.

Laser-texturing generated precisely the desired microgeometry. On nanostructural level, differently-sized Ti-droplets were formed stochastically by laser-induced-Ti-plasma. Live/dead-/Actin-stainings showed comparable results for all cohorts and surfaces in terms of survival and cell shape. On Ti-materials, cell growth showed no significant difference between the 3 cohorts. Alizarin quantification revealed the highest levels on laser-textured-surfaces; highest value for YH, followed by AH, lastly OP; no significance between AH/YH, but between OP/YH (p<0.0001). However, mineralization of all cohorts cultured on laser-textured-surfaces increased significantly (p<0.0001) compared to respective SLA-group, with >20fold higher value in the OP-cohort (AH:11fold, YH:6fold).

The data proves the biocompatibility of the laser-structured-Ti for young+aged cohorts. Osteogenic differentiation was significantly augmented on laser-treated-Ti. Most intriguingly, OP-donors could reach manifold increased mineralization, suggesting the novel laser texturing can counteract the osteoporotic phenotype. As osteogenesis-enhancing capacities may be related to mechanisms controlling cellular shape/fate, further investigations referring to this are currently ongoing. In conclusion, our laser-textured-Ti-materials are safe, can have a demand-oriented designer-surface-topography and represent a great potential for development into next-generation-implants suitable for different patient-cohorts, especially osteoporosis patients.


Bone & Joint Research
Vol. 11, Issue 8 | Pages 561 - 574
10 Aug 2022
Schulze-Tanzil GG Delgado Cáceres M Stange R Wildemann B Docheva D

Tendon is a bradytrophic and hypovascular tissue, hence, healing remains a major challenge. The molecular key events involved in successful repair have to be unravelled to develop novel strategies that reduce the risk of unfavourable outcomes such as non-healing, adhesion formation, and scarring. This review will consider the diverse pathophysiological features of tendon-derived cells that lead to failed healing, including misrouted differentiation (e.g. de- or transdifferentiation) and premature cell senescence, as well as the loss of functional progenitors. Many of these features can be attributed to disturbed cell-extracellular matrix (ECM) or unbalanced soluble mediators involving not only resident tendon cells, but also the cross-talk with immigrating immune cell populations. Unrestrained post-traumatic inflammation could hinder successful healing. Pro-angiogenic mediators trigger hypervascularization and lead to persistence of an immature repair tissue, which does not provide sufficient mechano-competence. Tendon repair tissue needs to achieve an ECM composition, structure, strength, and stiffness that resembles the undamaged highly hierarchically ordered tendon ECM. Adequate mechano-sensation and -transduction by tendon cells orchestrate ECM synthesis, stabilization by cross-linking, and remodelling as a prerequisite for the adaptation to the increased mechanical challenges during healing. Lastly, this review will discuss, from the cell biological point of view, possible optimization strategies for augmenting Achilles tendon (AT) healing outcomes, including adapted mechanostimulation and novel approaches by restraining neoangiogenesis, modifying stem cell niche parameters, tissue engineering, the modulation of the inflammatory cells, and the application of stimulatory factors.

Cite this article: Bone Joint Res 2022;11(8):561–574.


Bone & Joint Research
Vol. 11, Issue 5 | Pages 327 - 341
23 May 2022
Alagboso FI Mannala GK Walter N Docheva D Brochhausen C Alt V Rupp M

Aims

Bone regeneration during treatment of staphylococcal bone infection is challenging due to the ability of Staphylococcus aureus to invade and persist within osteoblasts. Here, we sought to determine whether the metabolic and extracellular organic matrix formation and mineralization ability of S. aureus-infected human osteoblasts can be restored after rifampicin (RMP) therapy.

Methods

The human osteoblast-like Saos-2 cells infected with S. aureus EDCC 5055 strain and treated with 8 µg/ml RMP underwent osteogenic stimulation for up to 21 days. Test groups were Saos-2 cells + S. aureus and Saos-2 cells + S. aureus + 8 µg/ml RMP, and control groups were uninfected untreated Saos-2 cells and uninfected Saos-2 cells + 8 µg/ml RMP.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 5 - 5
1 Dec 2021
Alagboso F Mannala G Steinmann S Docheva D Rupp M Brochhausen C Alt V
Full Access

Aim

Bone regeneration following the treatment of Staphylococcal bone infection or osteomyelitis is challenging due to the ability of Staphylococcus aureus to invade and persist within bone cells, which could possibly lead to antimicrobial tolerance and incessant bone destruction.

Here, we investigated the influence of Staphylococcal bone infection on osteoblasts metabolism and function, with the underlying goal of determining whether Staphylococcus aureus-infected osteoblasts retain their ability to produce extracellular mineralized organic matrix after antibiotic treatment.

Method

Using our in vitro infection model, human osteoblasts-like Saos-2 cells were infected with high-grade Staphylococcus aureus EDCC 5055 strain, and then treated with 8 µg/ml rifampicin and osteogenic stimulators up to 21-days.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 76 - 76
1 Dec 2021
Mannala G Rupp M Alagboso F Docheva D Alt V
Full Access

Aim

In vivo biofilm models play major role to study biofilm development, morphology, and regulatory molecules involve in biofilm. Due to ethical restrictions, the use mammalian models are replaced with other alternative models in basic research. Recently, we have developed insect infection model G. mellonella larvae to study implant associated biofilm infections. This model organism is easy to handle, cheap and ethical restriction free and could be used for the high through put screening of antimicrobial compounds to treat biofilm. To promote the use of this model in basic research we aimed to validate this based on the typical biofilm features such as less susceptible to the antibiotics, complexity of the biofilm structure and gene expression profile of biofilms.

Method

G. mellonella larvae are maintained at 30oC on artificial diet in an incubator. Titanium and Stainless steel K-wires were cut into small pieces with size of 4mm. After sterilization with 100% alcohol, these K-wires were pre-incubated in S. aureus bacterial suspension (5×106 CFU/ml) for 30 min, washed in PBS and implanted inside the larva after with help of scalpel. The larvae were incubated at 37oC for two day for the survival analysis. To analyze the less susceptibility of the biofilms towards antibiotics, the larvae were treated with gentamicin and compared survival with planktonic infection in G. mellonella. To reveal the complex structure of biofilm, the implants were removed and processed for the MALDI analysis. Whole genome-based transcriptome of biofilm was performed to explore the changes in transcriptional landscapes.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 87 - 87
1 Dec 2021
Mannala G Rupp M Walter N Brunotte M Alagboso F Docheva D Brochhausen C Alt V
Full Access

Aim

Here, we are aimed to evaluate bacteriophage (191219) to treat S. aureus implant-associated bone infections by means of testing against S. aureus during its planktonic, biofilm and intracellular growth phases and finally assessing antimicrobial effect on in vivo biofilm formed on metal K-wire in an alternative insect model Galleria mellonella.

Method

The bacteriophages (191219) were provided from D&D Pharma GmbH. These bacteriophages were tested against S. aureus EDCC 5055 (MSSA) and S. aureus DSM 21979 (MRSA) strains. To assess the activity of bacteriophages against planktonic growth phase, bacteriophages, and S. aureus EDCC 5055(1×107 CFU/ml) were co-cultured in LB media as multiplicity of infection (MOI) of 10, 1, 0.1, and 0.01 for 24 hours at 37oC and finally plated out on the LB agar plates to estimate the bacterial growth. The antimicrobial activity of bacteriophages on biofilms in vitro was measured by analysing the incubating the several fold dilutions of bacteriophages in LB media with biofilms formed on 96-well plate. The eradication of biofilm was analysed with crystal violet as well as CFU analysis methods. Later, the effect of bacteriophages on intracellular growth of S. aureus in side osteoblast was tested by treating the S. aureus infected osteoblasts at 2h, 4h and 24h time points of post treatment. In addition, we have analysed synergistic effect with gentamicin and rifampicin antibiotics to clear intracellular S. aureus. Finally, experiments are performed to prove the effect of bacteriophages to clear in vivo biofilm using alternative insect model G. mellonella as well as to detect the presence of bacteriophages inside the osteoblasts through transmission electron microscopy (TEM) analysis.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 40 - 40
1 Nov 2021
Pattappa G Reischl F Jahns J Lang S Zellner J Docheva D Angele P
Full Access

Introduction and Objective

The meniscus is composed of two distinct regions, a vascular outer zone and an avascular inner zone. Due to vascularization, tears within the vascular zone can be treated by suturing. However, tears in the avascular zone have a poor healing capacity and partial meniscectomy is used to prevent further pain, although this leads to early osteoarthritis. Previous studies have demonstrated that the vascular zone contains a progenitor population with multilineage differentiation potential. Isolation and propagation of these progenitors can be used to develop cell-based therapies for treating meniscal defects. In vivo, the meniscus resides under a low oxygen environment, also known as physioxia (2–7% oxygen) and previous work suggests that it promotes the meniscal phenotype. The objective of the study was to isolate progenitor populations from both meniscus regions and to examine their clonogenecity and differentiation potential under both hyperoxia (20% oxygen) and physioxia (2% oxygen). We hypothesize that physioxia will have a beneficial effect on colony formation and trilineage differentiation of meniscal cells.

Materials and Methods

Human meniscus (n =4; mean age: 64 + 6) tissue was split into vascular and avascular regions, finely cut into small pieces and then sequentially digested in pronase (70U/mL) and collagenase (200U/mL) at 370C. Avascular and vascular meniscus cells were counted and split equally for expansion under hyperoxia and physioxia at a seeding density of 5 × 103 cells/cm2. At passage 1, cells were seeded at 2, 5 and 20 cells/cm2 in 10cm dishes for observing colony formation using crystal violet assay. At passage 3, vascular and avascular meniscus cells were differentiated towards the chondrogenic, osteogenic and adipogenic lineage. Chondrogenesis was evaluated using DMMB staining for GAG deposition, osteogenesis was assessed using Alizarin Red staining for calcium deposition, whilst adipogenesis was observed using Oil-Red-O staining for fat droplets.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 71 - 71
1 Mar 2021
Pattappa G Krueckel J Johnstone B Docheva D Zellner J Angele P
Full Access

Osteoarthritis (OA) is a progressive and degenerative joint disease resulting in changes to articular cartilage. In focal early OA defects, autologous chondrocyte implantation (ACI) has a 2-fold failure rate due to poor graft integration and presence of inflammatory factors (e.g. Interleukin-1β). Bone marrow derived mesenchymal stem cells (MSCs) are an alternative cell source for cell-based treatments due to their chondrogenic capacity, though in vivo implantation leads to bone formation. In vivo, chondrocytes reside under an oxygen tension between 2–7% oxygen or physioxia. Physioxia enhances MSC chondrogenesis with reduced hypertrophic marker (collagen X and MMP13) expression compared to hyperoxic conditions (20% oxygen). This study sought to understand whether implantation of physioxic preconditioned MSCs improves cartilage regeneration in an early OA defect model compared to hyperoxic MSCs. Bone marrow extracted from New Zealand white rabbits (male: 5–6 months old; n = 6) was split equally for expansion under 2% (physioxia) or 20% (hyperoxia) oxygen. Chondrogenic pellets (2 × 105 cells/pellet) formed at passage 1 were cultured in the presence of TGF-β1 under their expansion conditions and measured for their wet weight and GAG content after 21 days. During bone marrow extraction, a dental drill (2.5mm diameter) was applied to medial femoral condyle on both the right and left knee and left untreated for 6 weeks. Following this period, physioxia and hyperoxia preconditioned MSCs were seeded into a hyaluronic acid (TETEC) hydrogel. Fibrous tissue was scraped and then MSC-hydrogel was injected into the right (hyperoxic MSCs) and left (physioxia MSCs) knee. Additional control rabbits with drilled defects had fibrous tissue scrapped and then left untreated without MSC-hydrogel treatment for the duration of the experiment. Rabbits were sacrificed at 6 (n = 3) and 12 (n = 3) weeks post-treatment, condyles harvested, decalcified in 10% EDTA and sectioned using a cryostat. Region of interest was identified; sections stained with Safranin-O/Fast green and evaluated for cartilage regeneration using the Sellers scoring system by three blinded observers. Physioxic culture of rabbit MSCs showed significantly shorter doubling time and greater cell numbers compared to hyperoxic culture (∗p < 0.05). Furthermore, physioxia enhanced MSC chondrogenesis via significant increases in pellet wet weight and GAG content (∗p < 0.05). Implantation of physioxic preconditioned MSCs showed significantly improved cartilage regeneration (Mean Sellers score = 7 ± 3; ∗p < 0.05) compared to hyperoxic MSCs (Sellers score = 12 ± 2) and empty defects (Sellers score = 17 ± 3). Physioxia enhances in vitro rabbit MSC chondrogenesis. Subsequent in vivo implantation of physioxia preconditioned MSCs improved cartilage regeneration in an early OA defect model compared to hyperoxic MSCs. Future studies will investigate the mechanisms for enhanced in vivo regeneration using physioxia preconditioned MSCs.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 70 - 70
1 Mar 2021
Stich T Krenek T Kovarik T Docheva D
Full Access

Numerous implanted hip and knee joint arthroplasties have to be replaced due to early or late loosening of the implant, a failure of osteointegration with fibrous tissue at the bone-implant-interface. This could be counteracted by ensuring that cells which attach to the implant surface differentiate towards bone cells afterwards. For this reason, human mesenchymal stem cells (hMSCs) will be included in this study. These cells are naturally available at the bone-implant-interface, multipotent and therefore ideal to study the osteoinductivity of a material. The goal of this pilot study was to test the cell response towards three different titanium grades with a novel surface structuring, as a first step towards achieving an improved implant surface for enhanced osteointegration. Disk-shaped titanium scaffolds with a diameter of 12 mm and a height of 1.2 mm were used. The surface topography (500 µm × 500 µm × 300 µm pores) was generated via laser treatment of the surface. By using nanosecond pulsed laser technique, a rough surface with micro- and nanostructural (titanium droplets) features was automatically formed. Three different batches made of commercially pure titanium grades 1 and 2 (Ti1/Ti2) or Ti6Al4V alloy grade 5 (Ti5) were produced. Four cell types were analysed on these batches: primary hMSCs from one donor (m, 25 y), periosteum derived cells (PDCs), human osteoblasts (hOBs) and periodontal ligament cells (PDLs). Cells were seeded on Ti1, Ti2 and Ti5 scaffolds in triplicates. Resazurin assay to examine cell viability was conducted with all cell types. Measurements were executed on several days after seeding, from day one up to day 14. Actin staining as well as live/dead staining was performed with hMSCs cultured on titanium for 1, 3, 5 or 7 days. The cell viability assay revealed early turning points of growth for osteogenic hOBs (day 3) and PDCs (day 7). HMSCs grew steadily on the material and non-osteogenic PDLs stayed in plateau throughout the cultivation period. With respect to the material, cells demonstrated better proliferation on Ti1 and Ti2 than on Ti5. Live/dead staining showed a high survival rate of hMSCs at each time point and on all three titanium grades, with a neglectable number of dead cells. Actin staining confirmed an enhanced spreading and stretching of hMSCs on Ti1 and Ti2 compared to hMSCs on Ti5. Our pilot data indicates that cells react to different titanium compositions, revealed by increased proliferation on commercially pure titanium (Ti1/2). Furthermore, our results demonstrate that osteogenic cells prefer the novel surface structuring in comparison to non-osteogenic PDL cells, which stayed in plateau. The turning points of growth (hOBs/PDCs) suggest an osteosupportiveness of the surface. Although hMSCs did not show a turning point in growth, their growth was steady and resulted in the highest number of cells along with a well stretched morphology. Due to their good proliferation and response to the material, hMSCs are currently being used for evaluating the osteogenic potential of the novel scaffolds.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 66 - 66
1 Dec 2020
Chu J Pfeifer C Alt V Docheva D
Full Access

Introduction

Cell-based tendon engineering is an attractive alternative therapeutic approach to established treatments of tendon injuries. Numerous cell types are promising source of tendon engineering; however, there are certain disadvantages for each cell type. Interestingly, dermal fibroblasts (DFs) are able to transdifferentiate into other cell types, they are widely distributed in dermis and easy to harvest and isolate. Furthermore, pilot clinical studies suggested a promising therapeutic potential of autologous DFs for discorded tendons (Connell et al., 2009&2011), but the underlining repair mechanisms remain unclarified. To investigate tenogenic differentiation process in great detail, we have previously established a three-dimensional (3D) cell sheet model, comprising of three consecutive step (expansion, stimulation and maturation) leading to the formation of 3D tendon-like tube (Hsieh et al., 2018; Yan et al., 2020). Hence, the aim of this study was to carry out pilot examination of the tenogenic potential of human DFs (hDFs) by implementing the 3D cell sheet model.

Methods

hDFs (company purchased, n=2), hBMSCs (human bone marrow mesenchymal stem cells, n=1) and hTSPCs (human tendon stem/progenitor cells, n=1) were used and subjected to the 3D model. In 2D culture, semi-qPCR was performed to validate the expression of DF markers in hDFs, namely NTN1, PDPN and CD26 for papillary dermis layer, and PPARG, ACTA2 and CD36 for reticular dermis layer). FACS analysis and immunofluorescence were employed to validate expression of CD73, CD90, CD105 and vimentin (mesenchyme marker), respectively. After harvesting the 3D cell sheets, wet weigh measurements, H&E and collagen type I stainings, and semi-qPCR for Scleraxis and tenomodulin were executed.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 16 - 16
1 Jul 2020
Docheva D Lin D
Full Access

Tenomodulin (Tnmd) is the best known mature tendon factor for tendon and ligament tissues with reported important regulatory roles1. In addition, Tnmd C-terminal cysteine-rich domain has been descibed to exert anti-angiogenic functions in in vitro angiogenic assays as well as in vivo models of tendon injury and age-associated cardiac valve diseases1, 2. Interestingly, Tnmd expresson in the intervertebral disc (IVD), which is normally avascular tissue, has been also suggested3. Hence, the purpose of this study was first, to map the exact expression pattern of Tnmd during IVD development and aging and second, by implementing Tnmd-knockout mouse model, to examine if Tnmd plays a role in IVD homeostasis.

Histological analyses (hematoxylin/eosin, Safranin O, CD31 for endothelium, TUNEL for apoptosis and type X collagen and Runx2 for hypetrophy) were performed on Tnmd −/−, Tnmd −/− and chondromodulin I Chmd 1 −/− (Tnmd only homolog) double knockout and wild type mice WT (n = three to five) to examine IVD degeneration. Real time PCR was implemented to explore gene expression chnages in annulus fibrous (AF) between Tnmd −/− and WT mice. In addition, outer AF (OAF) cells were isolated from both genotypes to further determine cellular phenotype and assess effects on co-culture with human umbical vein endothelial cells (HUVECs). Statistical differences between two groups were determined with t-test. In multiple comparisons, one-way ANOVA was followed by Bonferroni post-hoc correction.

Tnmd was expressed in a temporal manner in OAF and to very low extent in NP. Tnmd −/− mice exhibited more rapid progression of age-related IVD degeneration. These signs included smaller collagen fibril diameter, reduced multiple IVD- and tendon/ligament-related gene expression, induced angiogenesis and inflamatory cell infiltration in OAF as well as more hypertrophic-like chondrocytes in the NP. In addition, Tnmd−/− Chm1 −/− mice displayes not only accelerated IVD phenotpye, but also ectopic bone formation in the IVD. Lastly, the abscence of Tnmd in OAF-derived cells significantly promoted HUVECs migratory capacity.

These findings provide clear evidence that Tnmd plays a critical role in IVD homeostasis.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 18 - 18
1 Jul 2020
Pattappa G Koch M Weber J Lang S Bohrer A Johnstone B Docheva D Zellner J Angele P Krueckel J Franke D
Full Access

Osteoarthritis (OA) is one of the most prevalent joint diseases involving progressive and degenerative changes to cartilage resulting from a variety of etiologies including post-traumatic incident or aging. OA lesions can be treated at its early stages through cell-based tissue engineering therapies using Mesenchymal Stem Cells (MSCs). In vivo models for evaluating these strategies, have described both chondral (impaction) and osteochondral (biopsy punch) defects. The aim of the investigation was to develop a compact and reproducible defect inducing post-traumatic degenerative changes mimicking early OA. Additionally, a pilot study to evaluate the efficacy of MSC-hydrogel treatment was also assessed.

Surgery was performed on New Zealand white rabbits (male, 5–8 months old) with defects created on medial femoral condyle. For developing an appropriate defect, three approaches were used for evaluation: a biopsy punch (n = three at six and twelve weeks), an impaction device1 (n = three at six and twelve weeks) and a dental drill model (n = six at six and twelve weeks). At stated time points, condyles were harvested and decalcified in 10% EDTA, then embedded in Tissue-Tek and sectioned using a cryostat. Upon identification of region of interest, sections were stained with Safranin-O/Fast green and scored using OARSI scoring system by two blinded observers2. For the pilot study, autologous bone marrow was harvested from rabbits and used to isolate and expand MSCs. The Dental drill model was applied to both knee condyles, left untreated for six weeks at which stage, PKH26 fluorescently labelled MSCs were seeded into a hyaluronic acid hydrogel (TETEC). Repair tissue was removed from both condyles and MSC-hydrogel was injected into the left knee, whilst right knee was left empty. Rabbits were sacrificed at one (n = 1), six (n = 3) and twelve (n = 3) weeks post-treatment, processed as previously described and cartilage regeneration evaluated using Sellers score3.

Impacted condyles exhibited no observed changes histologically (Mean OARSI score = 1 + 1), whereas biopsy punched and dental drilled defects demonstrated equal signs of cartilage erosion (OARSI score = 3 + 1) at assessed time points. However, biopsy punched condyles formed a diffusive defect, whereas dental drilled condyles showed a more defined, compact and reproducible defect. In the pilot study, PKH-labelled MSCs were observed at one and six weeks post-implantation within the defect space where hydrogel was injected. Tissue regeneration assessment indicated no difference between empty (Mean Sellers score = 14 + 2) and MSC treated defects (Sellers score = 16 + 5) at six weeks post-injection. At twelve weeks, MSC treated defects showed improved tissue regeneration with substantial subchondral bone restoration and good integration of regenerative cartilage with surrounding intact tissue (Sellers score = 10 + 1), whereas untreated defects showed no change in regeneration compared to six weeks (Sellers score = 16 + 2).

Dental drill model was found to be the appropriate strategy for investigating early OA progression and treatment. Application of MSCs in defects showed good cartilage regeneration after twelve weeks application, indicating their promise in the treatment of early OA defects.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 126 - 126
1 Nov 2018
Cáceres MD Docheva D
Full Access

The establishment of a proper musculoskeletal system depends on the well-organized and synchronized development of muscle, tendon and cartilage/bone. In tendon biology, a great progress in identifying tendon-specific genes (Scleraxis, Mohawk, Tenomodulin) had been made in the last decade. However, there are many open questions regarding the exact function of genes in tendon development and homeostasis. The purpose of this study was to perform a systematic review of publications describing tendon-related genes, which were studied in-depth and characterized by using knockout technologies and the respectively generated transgenic mouse. Method: Literature search was carried out in Pubmed using “tendon” and “mouse knockout” and “phenotype” and was not limited to year. Results: We report in a tabular manner, that from a total of 25 tendon-related genes, in 23 of the respective knockout mouse models phenotypic changes were detected. Additionally, in some of the models it was described at which developmental stages these changes appeared and progressed. Interestingly, so far only loss of Scleraxis and TGFbeta signaling led to severe tendon developmental phenotypes, while mice deficient for various proteoglycans, Mohawk, EGR1 and 2, and Tenomodulin exhibited mild phenotypes. This suggests that in general the tendon developmental program is well backup and specifically that among the members of the proteoglycan family there are clear compensatory effects. In future, it will be of great importance to discover additional master tendon transcription factors as well as genes that play indispensable roles in tendon development.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 38 - 38
1 Nov 2018
Yin H Popov C Schieker M Nerlich M Docheva D
Full Access

Background: The exact pathways of collagen remodeling in tendon tissue are not well understood. Therefore, we have established a 3D collagen gel system and studied the remodeling capacity of two different TSPC lines: young, Y-TSPC and aged/degenerative, A-TSPC. We specifically investigated the involvement of integrin receptors in the remodeling process. Methods: Y- and A-TSPC were derived from human Achilles tendon. RT-PCR was used to assess the expression of collagen-binding integrins. Integrins a1 and a11 were silenced by lentiviral delivery of shRNA in the Y-TSPC. Control-shRNA, a1-shRNA and a11-shRNA virus was given for 24h and then cells were selected with zeocin for 10 days. The integrin knockdown (KD) efficiency was assessed by quantitative PCR and western blotting. Last, time-lapse recording of gel contraction of Y-TSPC+con, Y-TSPC+a1KD, Y-TSPC+a11KD, and A-TSPC were performed. Results: Integrin a1 and a11 were significantly downregulated in A-TSPC. Therefore, to mimic the A-TSPC we carried out a1 and a11 KD in Y-TSPC. PCR and western blot validated very efficient KD. Analyses of collagen contraction revealed that Y-TSPC+a11KD had significant reduction in collagen contractibility comparable to A-TSPC phenotype. Regarding integrin a1, we found that this receptor had no effect on the contraction rate of TSPC. Thus, to our knowledge we have now identified for the first time a novel role of a11 integrin in tendon matrix remodeling, and a follow up analyses of the exact downstream cascade are on the way.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 23 - 23
1 Nov 2018
Pattappa G Zellner J Johnstone B Docheva D Angele P
Full Access

Mesenchymal Stem Cells (MSCs) are a candidate cell type for treating osteoarthritic focal defects. In vivo, cartilage and bone marrow reside under a low oxygen tension, between 2–7% oxygen or physioxia, that has been shown to enhance MSC chondrogenesis. However, chondrogenesis is inhibited in the presence of IL-1. Here, it was hypothesized that physioxia reduces IL-1 inhibited chondrogenesis. Human MSCs (Mean age, 32 years; n = 9) were split equally for expansion under either 2% (physioxia) or 20% (hyperoxia) oxygen. Chondrogenic pellets (2 × 105 MSCs/pellet) were formed and cultured in the presence of 10 ng/ml TGF-b1 and in combination with either 0.1 or 0.5 ng/ml IL-1 under their respective expansion conditions. Pellets were assessed for their wet weight, GAG and collagen II content and evaluated histologically (Collagen X and MMP-13). Statistical analysis was performed using a Two-way ANOVA with Tukey post-hoc test, significant differences stated when p < 0.05. A significant dose-dependent IL-1 inhibition in chondrogenesis was observed for pellet wet weight and GAG content under hyperoxia (p < 0.05). Physioxia alone significantly increased wet weight, GAG and collagen II content (p < 0.05) compared to hyperoxia. A donor-dependant response was observed, whereby 80% of donors responded to physioxia and their analysis showed significant increases in wet weight and GAG content in the presence IL-1(p < 0.05). Furthermore, reduced hypertrophy marker expression (Collagen X and MMP-13) was observed under physioxia in the presence of IL-1. The molecular signalling mechanisms controlling these responses are to be investigated.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 127 - 127
1 Nov 2018
Yan Z Yin H Nerlich M Pfeifer C Docheva D
Full Access

Tendons are dense connective tissues and critical components of the musculoskeletal system with known long repair process. Tissue engineering is a promising approach for achieving complete recovery of ruptured tendons. The most studies have focused on the combination of cells with various carriers; however, frequent times the biomaterials do not match the tissue organization and strength. For this reason, we first reviewed the literature for an alternative scaffold-free strategy for tendon engineering and second, we compared the cell sheet formation of two different cell types: bone marrow-derived mesenchymal stem cells (BM-MSCs) and tendon stem/progenitor cells (TSPCs). Methods: Literature search was performed in Pubmed using “tendon tissue engineering” and “scaffold-free” keywords and was limited to the last ten years. By using a 3-step protocol, BM-MSCs and TSPCs were induced to form cell sheets in 5 weeks. The sheets were compared by analysis for weight, diameter, cell density, tissue morphology (H&E and scoring) and cartilaginous matrix (DMMB and S.O. staining). Results: Scaffold-free models (cell sheets and pellet cultures) are available; however, further optimization is needed. Comparison between the two cell types clearly demonstrated that TSPCs form more mature cell sheet, while BMSCs form larger but less organized and differentiated sheet as judged by higher cell density and lower scoring outcome. Future efforts will focus on identifying mechanisms to speed BM-MSC sheet formation and maturation, which can in turn lead to development of new methodology for scaffold-free tendon tissue engineering.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 1 - 1
1 Nov 2018
Docheva D
Full Access

Tendon and ligament tissues are fascinating in their simplistic appearance of tissue architecture coupled with outstanding biomechanical properties. In the last decade, the mechanisms governing their development, degenerative disease progression and step-wise repair process are becoming better understood. In this talk, I will present an overview of our basic research work on these following points. (i) Tendon generation: I will discuss our finding on the role of growth and biomechanical factors influencing tendon stem/progenitor cells; (ii) Tendon degeneration: I will provide evidences how disturbed cell-cell and cell-matrix contacts are involved in loss of tissue integrity; (iii) Tendon regeneration: I will present in vivo data on the application and performance of various cell populations in tendon repair.