header advert
Results 21 - 27 of 27
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 1038 - 1039
1 Nov 1997
COURT-BROWN CM


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 4 | Pages 698 - 698
1 Jul 1997
COURT-BROWN CM


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 1 | Pages 170 - 171
1 Jan 1997
COURT-BROWN CM


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 4 | Pages 580 - 583
1 Jul 1996
Court-Brown CM Will E Christie J McQueen MM

We performed a prospective, randomised study on 50 patients with Tscherne C1 tibial diaphyseal fractures comparing treatment with reamed and unreamed intramedullary nails. Our results show that reamed nailing is associated with a significantly lower time to union and a reduced requirement for a further operation. Unreamed nailing should not be used in the treatment of the common Tscherne C1 tibial fracture.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 404 - 409
1 May 1996
McQueen MM Hajducka C Court-Brown CM

We performed a prospective, randomised trial on 120 patients with redisplaced fractures of the distal radius comparing four methods of treatment. The four treatment groups, each containing 30 patients, were remanipulation and plaster, open reduction and bone grafting, and closed external fixation with and without mobilisation of the wrist at three weeks.

The radiological results showed improvement in angulation of the distal radius for the open reduction and bone grafting group. Functional results at six weeks, three and six months and at one year, however, showed no difference between any of the four groups. The main influence on final outcome was carpal malalignment which had a statistically significant negative effect on function.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 99 - 104
1 Jan 1996
McQueen MM Court-Brown CM

We made a prospective study of 116 patients with tibial diaphyseal fractures who had continuous monitoring of anterior compartment pressure for 24 hours. Three patients had acute compartment syndrome (2.6%).

In the first 12 hours of monitoring, 53 patients had absolute pressures over 30 mmHg and 30 had pressures over 40 mmHg, with four higher than 50 mmHg. Only one patient had a differential pressure (diastolic minus compartment pressure) of less than 30 mmHg; he had a fasciotomy.

In the second 12-hour period 28 patients had absolute pressures over 30 mmHg and seven over 40 mmHg. Only two had differential pressures of less than 30 mmHg; they had fasciotomies. None of our 116 patients had any sequelae of the compartment syndrome at their latest review at least six months after injury.

A threshold for decompression of 30 mmHg would have indicated that 50 patients (43%) would have required fasciotomy, and at a 40 mmHg threshold 27 (23%) would have been considered for an unnecessary fasciotomy.

In our series, the use of a differential pressure of 30 mmHg as a threshold for fasciotomy led to no missed cases of acute compartment syndrome. We recommended that decompression should be performed if the differential pressure level drops to under 30 mmHg.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 95 - 98
1 Jan 1996
McQueen MM Christie J Court-Brown CM

We reviewed 25 patients with tibial diaphyseal fractures which had been complicated by an acute compartment syndrome. Thirteen had undergone continuous monitoring of the compartment pressure and the other 12 had not.

The average delay from injury to fasciotomy in the monitored group was 16 hours and in the non-monitored group 32 hours (p < 0.05). Of the 12 surviving patients in the monitored group, none had any sequelae of acute compartment syndrome at final review at an average of 10.5 months. Of the 11 surviving patients in the non-monitored group, ten had definite sequelae with muscle weakness and contractures (p < 0.01). There was also a significant delay in tibial union in the non-monitored group (p < 0.05).

We recommend that, when equipment is available, all patients with tibial fractures should have continuous compartment monitoring to minimise the incidence of acute compartment syndrome.