header advert
Results 1 - 6 of 6
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1135 - 1139
1 Nov 2023
Young SW Chen W Clarke HD Spangehl MJ

Prophylactic antibiotics are important in reducing the risk of periprosthetic joint infection (PJI) following total knee arthroplasty. Their effectiveness depends on the choice of antibiotic and the optimum timing of their administration, to ensure adequate tissue concentrations. Cephalosporins are typically used, but an increasing number of resistant organisms are causing PJI, leading to the additional use of vancomycin. There are difficulties, however, with the systemic administration of vancomycin including its optimal timing, due to the need for prolonged administration, and potential adverse reactions. Intraosseous regional administration distal to a tourniquet is an alternative and attractive mode of delivery due to the ease of obtaining intraosseous access. Many authors have reported the effectiveness of intraosseous prophylaxis in achieving higher concentrations of antibiotic in the tissues compared with intravenous administration, providing equal or enhanced prophylaxis while minimizing adverse effects. This annotation describes the technique of intraosseous administration of antibiotics and summarizes the relevant clinical literature to date.

Cite this article: Bone Joint J 2023;105-B(11):1135–1139.


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 74 - 80
1 Jun 2021
Deckey DG Rosenow CS Verhey JT Brinkman JC Mayfield CK Clarke HD Bingham JS

Aims

Robotic-assisted total knee arthroplasty (RA-TKA) is theoretically more accurate for component positioning than TKA performed with mechanical instruments (M-TKA). Furthermore, the ability to incorporate soft-tissue laxity data into the plan prior to bone resection should reduce variability between the planned polyethylene thickness and the final implanted polyethylene. The purpose of this study was to compare accuracy to plan for component positioning and precision, as demonstrated by deviation from plan for polyethylene insert thickness in measured-resection RA-TKA versus M-TKA.

Methods

A total of 220 consecutive primary TKAs between May 2016 and November 2018, performed by a single surgeon, were reviewed. Planned coronal plane component alignment and overall limb alignment were all 0° to the mechanical axis; tibial posterior slope was 2°; and polyethylene thickness was 9 mm. For RA-TKA, individual component position was adjusted to assist gap-balancing but planned coronal plane alignment for the femoral and tibial components and overall limb alignment remained 0 ± 3°; planned tibial posterior slope was 1.5°. Mean deviations from plan for each parameter were compared between groups for positioning and size and outliers were assessed.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 28 - 28
1 Oct 2020
Deckey DG Rosenow CS Verhey JT Mayfield CK Christopher ZK Clarke HD Bingham JS
Full Access

Introduction

Robot-assisted total knee arthroplasty (RA-TKA) is theoretically more accurate for component positioning than TKA performed with mechanical instruments (M-TKA). Furthermore, the ability to quantify soft tissue laxity and adjust the plan prior to bone resection should reduce variability in polyethylene thickness. This study was performed to compare accuracy to plan for component positioning and polyethylene thickness in RA-TKA versus M-TKA.

Methods

199 consecutive primary TKAs (96 C-TKA and 103 RA-TKA) performed by a single surgeon were reviewed. Full-length standing and knee radiographs were obtained pre and post-operatively. For M-TKA, measured resection technique was used. Planned coronal plane femoral and tibial component alignment, and overall limb alignment were all 0° to the mechanical axis; tibial posterior slope was 2°; and polyethylene thickness was 9mm. For RA-TKA, individual component position was adjusted to assist balance the gaps but planned coronal plane alignment for the femoral and tibial components and overall limb alignment had to remain 0+/− 3°; planned tibial posterior slope was 1.5°. Planned values and polyethylene thickness for RA-TKA were obtained from the final intra-operative plan. Mean deviations from plan for each parameter were compared between groups (ΔFemur, ΔTibia, ΔPS, and polyethylene thickness) as were distal femoral recut and tourniquet time.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 55 - 55
1 Oct 2019
Young SW Clarke HD Moore GA Zhang M Probst NE Spangehl MJ
Full Access

Introduction

Intraosseous administration of low dose vancomycin has been proven to produce 6 to 20 times higher tissue concentrations compared to intravenous administration in both primary and revision knee replacement. However, these superior levels are achieved when the antibiotic given intraosseously is administered distal to a tourniquet that is inflated for the majority of the case. With increasing interest in limited, or no, tourniquet use during TKA we sought to study the tissue concentrations achieved with limited tourniquet use and intraosseously administered vancomycin compared to weight-based, time optimized intravenous administration.

Methods

Twenty-four patients undergoing primary TKA were randomized to two groups. The Intravenous (IV) Group received weight based (15mg/kg) vancomycin timed to finish before incision. The Intraosseous (IO) Group received 500 mg of vancomycin injected as a bolus through a needle into the proximal tibia distal to an inflated tourniquet prior to skin incision. In the IO group, the tourniquet was deflated 10 minutes following the injection and re-inflated only for cementation. In the IV group, the tourniquet was only inflated for cementation. During the procedure, fat and bone samples were taken at regular intervals. Tissue antibiotic concentrations were measured using a validated technique involving high performance liquid chromatography.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 22 - 22
1 Oct 2018
Saffi M Young SW Spangehl MJ Clarke HD
Full Access

Introduction

Tibial component malrotation is associated with pain, stiffness and altered patellofemoral kinematics in total knee arthroplasty (TKA). However, accurately measuring tibial component rotation following TKA is difficult. Proposed protocols utilizing computed tomography (CT) are not well validated and can be time consuming. This study aimed to; 1) Validate and compare the reproducibility of the Berger (2D-CT) and Mayo (3D-CT) protocols; 2) Validate a simple, and potentially rapid screening measurement using an anatomical distance on 2D axial CT- the Centre of Tibial Tray to Tibial Tubercle (CTTT) distance.

Methods

Rotational alignment of 70 TKA patients were evaluated by 3 independent observers using the Berger, and Mayo protocols, which have been previously described, and a new CTTT protocol (Figure 1). The inter and intra-rater interclass correlation coefficients (ICC's), mean difference between measurements and the mean measurement times were calculated. Linear regression analysis was performed to give a coefficient of determination (R2).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 179 - 179
1 Sep 2012
Spangehl MJ Clarke HD
Full Access

Introduction

Opponents of patellar resurfacing during Total Knee Arthroplasty (TKA) note unique complications associated with resurfacing. Problems include over-stuffing (the creation of a composite patellar-prosthesis thickness greater than the native patella) that may contribute to reduced range of motion; and creation of a patellar remnant that is too thin (in order to avoid over-stuffing) that may contribute to post-operative fracture. Factors including surgical technique, prosthesis design and patient anatomy may contribute to these problems. This study was performed to define the native patellar anatomy, and to compare the effect of differences in component thickness between manufacturers.

Methods

This retrospective, IRB approved study reviewed 803 knees that underwent primary TKA between 2005 and 2011 with a single surgeon. Patellar resurfacing was performed with a round, polyethylene component from one of two different implant designs using the same surgical technique. Data recorded for each patient included: gender; patellar thickness before and after resurfacing; the dimensions and manufacturer of the prosthesis. The residual patellar bone thickness after resection was calculated.