header advert
Results 1 - 4 of 4
Results per page:
Bone & Joint Research
Vol. 10, Issue 5 | Pages 298 - 306
1 May 2021
Dolkart O Kazum E Rosenthal Y Sher O Morag G Yakobson E Chechik O Maman E

Aims

Rotator cuff (RC) tears are common musculoskeletal injuries which often require surgical intervention. Noninvasive pulsed electromagnetic field (PEMF) devices have been approved for treatment of long-bone fracture nonunions and as an adjunct to lumbar and cervical spine fusion surgery. This study aimed to assess the effect of continuous PEMF on postoperative RC healing in a rat RC repair model.

Methods

A total of 30 Wistar rats underwent acute bilateral supraspinatus tear and repair. A miniaturized electromagnetic device (MED) was implanted at the right shoulder and generated focused PEMF therapy. The animals’ left shoulders served as controls. Biomechanical, histological, and bone properties were assessed at three and six weeks.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 18 - 18
1 Nov 2018
Kazum E Dolkart O Rozental Y Sherman H Amar E Salai M Maman E Chechik O
Full Access

Drilling through bone is a complex action that requires precise motor skills of an orthopedic surgeon. In order to minimize plunging and soft tissue damage, the surgeon must halt drill progression precisely following penetration of the far cortex. The purpose of this study was to create a low-cost and easy-to-use drilling simulator to train orthopedic residents in reducing the drill plunging depth. This prospective observational study was performed in the division of orthopedic surgery of a single tertiary medical center. The participants included 13 residents and 7 orthopedic specialists. The simulator consisted of a synthetic femur bone model and ordinary modeling clay, and the training unit consisted of a disposable plastic tube (∼US$14), clamps (∼US$58) and a power drill + drill bit (standard hospital equipment). Plunging depths were measured by the simulator and compared between orthopedic specialists, the 6 “senior residents” (3+ years) and the 7 “junior residents” during a training session. Measurements were taken again 2 weeks following the training session. Initially, the plunging depths of the junior residents were significantly greater compared to those of the orthopedic specialists (7.00 mm vs 5.28 mm, respectively, p < 0.038). There was no similarly significant difference between the senior residents and the orthopedic experts ([6.33 mm vs. 5.28 mm, respectively; p = 0.18). The senior residents achieved plunging depths of 5.17 mm at the end of the training session and 4.7 mm 2 weeks later compared to 7.14 mm at the end of the training session and 6 mm 2 weeks later for the junior residents. This study demonstrated the capability of a low-cost drilling simulator as a training model for reducing the plunging depth during the drilling of bone and soft tissue among junior and senior residents.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 41 - 41
1 Apr 2017
Dolkart O Yehuda H Zarfati Y Brosh T Chechik O Maman E
Full Access

Background

The effect of corticosteroids on tendon properties is poorly understood, and current data are insufficient and conflicting. The objective of this study was to evaluate the effects of corticosteroids injection on intact and injured rotator cuff (RC) through biomechanical and radiographic analyses in a rat model.

Methods

70 rats were assigned to seven groups:1)control - saline injection;2) no tear + single methylprednisolone acetate (MTA) injection; 3) no tear + triple MTA injection; 4) tear + single saline injection; 5) tear + single MTA injection; 6) tear+ triple saline injections; 7) tear+ triple MTA injections. Triple injections were repeated once a week. Following unilateral supraspinatus (SSP) injuries, MTA was injected subacromialy. Rats were sacrificed 1 week after last injection. Shoulders were harvested, grossly inspected, SSP was evaluated biomechanically. Bone density at the tendon insertion site on the greater tuberosity (GT) were assessed with micro-computed tomography (CT).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 27 - 27
1 Jan 2017
Chevalier Y Pietschmann M Thorwaechter C Chechik O Adar E Dekel A Mueller P
Full Access

Treatment of massive rotator cuff tears can be challenging. Previous studies with irreparable rotator cuff tears showed good clinical results of tendon healing with the arthroscopic insertion of a protective biodegradable spacer balloon filled with saline solution between the repaired tendon and the acromion [1,2], but so far no scientific evidence has showed how the device alters pressures over the repaired tendon. This biomechanical study investigated the effects of a spacer inserted in the subacromial space on pressures over the repaired rotator cuff tendon in passive motion cycles typical for post-operative rehabilitation routines.

Six human cadaveric shoulders were prepared with the humerus cut 15cm below the joint and embedded in a pot, while the scapula fixed at three points on a plate. A rotator cuff tear was simulated and repaired using a suture anchor and a Mason-Allen suture. The specimens were then mounted on a custom-made pneumatic testing rig to induce passive motion cycles of adduction-abduction (90–0°) and flexion-extension (0–40°) with constant glenohumeral and superior loads and tension is exerted on the supraspinatus tendon with weights. A pressure sensor was placed between the supraspinatus tendon and the acromion. After pressure measurements for 15 cycles of each motion type, the InSpace balloon (OrthoSpace, Inc, Israel) was inserted and the specimens tested and pressure measured again for 15 cycles. Statistically significant changes in peak pressures were then measured before and after balloon.

Peak pressures were measured near 90 degrees abduction. No statistical differences were observed for internal-external rotation before and after balloon-shaped subacromial spacer was inserted. Mean pressures in abduction-adduction were significantly reduced from 121.7 ± 9.5 MPa to 51.5 ± 1.2 MPa. Peak pressures after repair were 1171.3 ± 99.5 MPa and 1749.6 ± 80.7 MPa in flexion-extension and abduction-adduction motion, respectively, and significantly decreased to 468.7 ± 16.0 MPa and 535.1 ± 27.6 MPa after spacer insertion (p<0.0001).

The use of the spacer above the repaired tendon reduced peak pressures and distributed them more widely over the sensor during both abduction-adduction and flexion-extension motions and therefore can reduce the stress on the rotator cuff repair. The InSpace system may reduce the pressure on the repaired tendon, thus potentially protecting the repair. Further studies to investigate this phenomenon are warranted, in particular relating these changes to shoulder kinematics following tear repair and spacer insertion.