header advert
Results 1 - 5 of 5
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 898 - 901
1 May 2021
Axelrod D Trask K Buckley RE Johal H

Aims

This study reviews the past 30 years of research from the Canadian Orthopedic Trauma Society (COTS), to identify predictive factors that delay or accelerate the course of randomized controlled trials in orthopaedic trauma.

Methods

We conducted a methodological review of all papers published through the Canadian Orthopaedic Trauma Society or its affiliates. Data abstracted included: year of publication; journal of publication; study type; number of study sites; sample size; and achievement of sample size goals. Information about the study timelines was also collected, including: the date of study proposal to COTS; date recruitment began; date recruitment ended; and date of publication.


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1165 - 1171
1 Sep 2013
Arastu MH Kokke MC Duffy PJ Korley REC Buckley RE

Coronal plane fractures of the posterior femoral condyle, also known as Hoffa fractures, are rare. Lateral fractures are three times more common than medial fractures, although the reason for this is not clear. The exact mechanism of injury is likely to be a vertical shear force on the posterior femoral condyle with varying degrees of knee flexion. These fractures are commonly associated with high-energy trauma and are a diagnostic and surgical challenge. Hoffa fractures are often associated with inter- or supracondylar distal femoral fractures and CT scans are useful in delineating the coronal shear component, which can easily be missed. There are few recommendations in the literature regarding the surgical approach and methods of fixation that may be used for this injury. Non-operative treatment has been associated with poor outcomes. The goals of treatment are anatomical reduction of the articular surface with rigid, stable fixation to allow early mobilisation in order to restore function. A surgical approach that allows access to the posterior aspect of the femoral condyle is described and the use of postero-anterior lag screws with or without an additional buttress plate for fixation of these difficult fractures.

Cite this article: Bone Joint J 2013;95-B:1165–71.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 7 - 7
1 Mar 2010
McCormack RG Zomar ML Panagiotopoulos KP Buckley RE Penner MJ Perey BH Pate GC Goetz TJ Piper MS
Full Access

Purpose: To compare failure rates, and patient functional outcomes, using the Dynamic Hip Screw (DHS) and Medoff Sliding Plate (MSP) for unstable intertrochanteric hip fractures.

Method: One hundred and sixty three consecutive patients with unstable intertrochanteric hip fractures, from three hospitals, were prospectively randomized to DHS or MSP. Inclusion and exclusion criteria were designed to focus on isolated unstable intertrochanteric hip fractures in ambulatory patients over age 60, without previous hip fractures or significant subtrochanteric extension. Patients were stratified by mental status and treating hospital. Randomization was performed intra operatively, after placement of a 135 degree guide wire. Follow up assessments were performed at regular intervals for a minimum of six months. The primary outcome was re-operation rate. The secondary outcome was patient function, using a validated outcome measure, the Hip Fracture Functional Recovery Score. Tertiary outcomes included: mortality, hospital stay, quality of reduction and mal union rate.

Results: 86 patients were randomized to DHS and 76 to MSP. The groups had similar patient demographics and pre fracture status (medical and functional). The patients had similar hospital course except there were more transfusions in the MSP group (2 vs. 1 unit). The quality of reduction was the same for each group but the operative time was longer in the MSP group (61 vs. 50 min). The rate of re-operation was low (3/86 in DHS and 2/76 in MSP) with no statistically significant difference. The indication for re-operation differed for the two groups as all three failures in the DHS group were related to screw cut out and both failures in the MSP arm were because of non union. The functional outcomes were the same for both groups with functional recovery scores at six months of 51% in the DHS arm and 49% in the MSP arm.

Conclusion: The two techniques produced similar results for the clinically important outcomes of the need for further surgery and functional status of the patients. For this challenging sub group of hip fractures, based on the equivalent results in this study either implant is a reasonable choice.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 336 - 339
1 Apr 2000
McCormack RG Brien D Buckley RE McKee MD Powell J Schemitsch EH

We randomised prospectively 44 patients with fractures of the shaft of the humerus to open reduction and internal fixation by either an intramedullary nail (IMN) or a dynamic compression plate (DCP). Patients were followed up for a minimum of six months. There were no significant differences in the function of the shoulder and elbow, as determined by the American Shoulder and Elbow Surgeons’ score, the visual analogue pain score, range of movement, or the time taken to return to normal activity. There was a single case of shoulder impingement in the DCP group and six in the IMN group. Of these six, five occurred after antegrade insertion of an IMN. In the DCP group three patients developed complications, compared with 13 in the IMN group. We had to perform secondary surgery on seven patients in the IMN group, but on only one in the DCP group (p = 0.016).

Our findings suggest that open reduction and internal fixation with a DCP remains the best treatment for unstable fractures of the shaft of the humerus. Fixation by IMN may be indicated for specific situations, but is technically more demanding and has a higher rate of complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 119 - 123
1 Jan 1996
Hildebrand KA Buckley RE Mohtadi NGH Faris P

We have devised a new scoring system using visual analogue scales (VAS) to determine the functional outcome in 15 patients with 20 displaced intra-articular calcaneal fractures, confirmed by CT. The average follow-up was 19 months.

A VAS was completed separately by the patient, the surgeon and an independent assessor. It showed satisfactory agreement between observers and strong correlations with a General Health Survey (SF36), a pain scale (McGill Pain Questionnaire) and a disease-specific, historical scale for calcaneal fractures (the Rowe score).