header advert
Results 1 - 4 of 4
Results per page:
Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 2 - 2
1 Nov 2018
Bolink SAAN Lenguerrand E Brunton L Hinds N Wylde V Blom AW Whitehouse M Grimm B
Full Access

Restoring native hip anatomy and biomechanics is important to create a well-functioning total hip arthroplasty (THA). Hip offset and leg length are regarded as the most important biomechanical characteristics. This study investigated their association with clinical outcomes including patient reported outcome measures (PROMs) and functional tests. This prospective cohort study was conducted in 77 patients undergoing primary THA (age=65±11 years). Hip offset and leg length were measured on anteroposterior radiographs of the hip pre- and postoperatively. Participants completed the Western Ontario & McMaster Universities Osteoarthritis Index (WOMAC) and performed functional tests (i.e. gait, single leg stance, sit-to-stand, block step-up) preoperatively, and 3 and 12 months postoperatively. A wearable motion sensor was used to derive biomechanical parameters. Associations between radiographic and functional outcomes were investigated with the Spearman's rho correlation coefficient. Subgroup comparisons were conducted for patients with more than 15% decreased or increased femoral offset after THA. Differences in postoperative offset and leg length had little impact on clinical outcomes. Femoral offset subgroups demonstrated no significantly different WOMAC function scores. In functional tests, patients with >15% decreased femoral offset after THA demonstrated more sagittal plane motion during block step-up (14.43° versus 10.66°; p=0.04) while patients with >15% increased femoral after THA demonstrated more asymmetry of frontal plane motion during block step-up (34.05% versus 14.18%; p=0.03). To create a well-functioning THA, there seems to be a reasonable safe zone regarding the reconstruction of offset and leg length.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 26 - 26
1 Jan 2017
Lenguerrand E Wylde V Brunton L Gooberman-Hill R Blom A Dieppe P
Full Access

Physical functioning in patients undergoing hip surgery is commonly assessed in three ways: patient-reported outcome measure (PROM), performance test, or clinician-administered measure. It is recommended that several types of measures are used concurrently to capture an extended picture of function. Patient fatigue and burden, time, resources and logistical constraints of clinic and research appointments mean that collecting multiple measures is seldom feasible, leading to focus on a limited number of measures, if not a single one. While there is evidence that performance-tests and PROMs do not fully correlate, correlations between PROMs, performance tests and clinician-administrated measures are yet to be evaluated. It is also not known if the associations between function and patient characteristics depend on how function is measured. The aim of our study was to use different measures to assess function in the same group of patients before their hip surgery to determine 1. how well PROMs, performance tests and clinician-administrated measures correlate with one another and 2. Whether these measures are associated with the same patient characteristics.

We conducted a cross-sectional analysis of the pre-operative information of 125 participants listed for hip replacement. The WOMAC function subscale, Harris Hip Score (HHS) and walk-, step- and balance-tests were assessed by questionnaire or during a clinic visit. Participant socio-demographics and medical characteristics were also collected. Correlations between functional measures were investigated with correlation coefficients (r). Regression models were used to test the association between the patient's characteristics and each of the three types of functional measures.

None of the correlations between the PROM, clinician-administrated measure and performance tests were very high (r<0.90). The highest correlations were found between the WOMAC-function and the HHS (r=0.7) or the Walk-test (r=0.6), and between the HHS and the walk-test(r=0.7). All the other performance-tests had low correlations with the other measures(r ranging between 0.3 and 0.5).

The associations between patient characteristics and functional scores varied by type of measure. Psychological status was associated with the WOMAC function (p-value<0.0001) but not with the other measures. Age was associated with the performance test measures (p-value ranging from ≤0.01 to <0.0001) but not with the WOMAC function. The clinician-administered (HHS) measure was not associated with age or psychological status.

When evaluating function prior to hip replacement clinicians and researchers should be aware that each assessment tool captures different aspects of function and that patient characteristics should be taken into account. Psychological status influences the perception of function; patients may be able to do more than they think they can do, and may need encouragement to overcome anxiety. A performance test like a walk-test would provide a more comprehensive assessment of function limitations than a step or balance test, although performance tests are influenced by age.

For the most precise description of functional status a combination of measures should be used. Clinicians should supplement their pre-surgery assessment of function with patient-reported measure to include the patient's perspective.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_9 | Pages 26 - 26
1 Feb 2013
Brunton L Bolink S van Laarhoven S Lipperts M Grimm B Heyligers I Blom A
Full Access

Accelerometer based gait analysis (AGA) is a potential alternative to the more commonly used skin marker based optical motion analysis system(OMAS). The use of gyroscopes in conjunction with accelerometers (i.e. inertial sensors), enables the assessment of position and angular movements of body segments and provides ambulatory kinematic characterisation of gait.

We investigated commonly used gait parameters and also a novel parameter, Pelvic obliquity (PO) and whether they can be used as a parameter of physical function and correlate with classic clinical outcome scores

Gait was studied in healthy subjects (n=20), in patients with end stage hip OA (n=20) and in patients with end stage knee OA (n=20). Subjects walked 20 metres in an indoor environment along a straight flat corridor at their own preferred speed. A 3D inertial sensor was positioned centrally between the posterior superior iliac spines (PSIS) overlying S1.

Comparing gait parameters of end stage hip OA patients with an age and gender matched healthy control group, significantly lower walking speed, longer step duration and shorter step length was observed. After correcting for walking speed between groups, significantly less average range of motion of PO (RoMpo) was observed for patients with end stage hip OA compared to healthy subjects and patients with end stage knee OA.

IGA allows objective assessment of physical function for everyday clinical practice and allows assessment of functional parameters beyond time only. IGA measures another dimension of physical function and could be used supplementary to monitor recovery of OA patients after TJR.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XIX | Pages 17 - 17
1 May 2012
Thompson A Walter S Brunton L Pickering G Mehendale S Bannister GC
Full Access

Background

Venous thromboembolism deterrent (TED) stockings are recommended for all orthopaedic patients. Clinical evidence supporting their use is limited and the risk of DVT increases four-fold if pressure gradients are reversed. This study aims to investigate the efficacy of TED stockings and their application using pressure gradients as the outcome measure.

Methods

We audited TED stockings over two discrete periods. In the first, cases were assessed for sizing, cutting in and tolerance. In the second we added pressure measurements along the saphenous vein; before and 2 and 3 days after surgery. Between the 2 series, a more rigorous sizing and re-sizing protocol was implemented.