Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 76 - 76
1 Nov 2018
Cresswell-Boyes A Mills D Davis G Boyde A
Full Access

As a part of the European Union BIOMED I study “Assessment of Bone Quality in Osteoporosis,” Sixty-nine second lumbar vertebral body specimens (L2) were obtained post mortem from 32 women and 37 men (age 24–92 years). Our initial remit was to study variations in density of the calcified tissues by quantitative backscattered electron imaging (BSE-SEM). To this end, the para-sagittal bone slices were embedded in PMMA and block surfaces micro-milled and carbon coated. Many samples were re-polished to remove the carbon coat and stained with iodine vapour to permit simultaneous BSE imaging of non-mineralised tissues - especially disc, annulus, cartilage and ligament - uncoated, at 50Pa chamber pressure. We have now studied most of these samples by 30-μm resolution high contrast resolution X-ray microtomography (XMT), typically 72 hours scanning time, thus giving exact correlation between high resolution BSE-SEM and XMT. The 3D XMT data sets were rendered using Drishti software to produce static and movie images for visualisation and edification. We have now selected a set of the female samples for reconstruction by 3D printing - taking as examples the youngest, post-menopausal, oldest, best, worst, and anterior and central compression fractures and anterior collapse with fusion to L3 - which will be attached to the poster display. The most porotic cases were also the most difficult to reconstruct. A surprising proportion of elderly samples showed excellent bone architecture, though with retention of fewer, but more massive, load-bearing trabeculae.


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 2 | Pages 209 - 213
1 May 1981
Wientroub S Boyde A Chrispin A Lloyd-Roberts G

Stereoradiography with a base shift of the source of illumination was used to produce pairs of radiographs to be measured by stereophotogrammetric techniques. The direction of shift was parallel with the longitudinal axis of the body, so that each radiograph in the stereopair could be used for other clinical purposes. A base shift of 10 centimetres with a distance of 100 centimetres between the focus and the film gave acceptable value of stereoscopic parallax. The radiographs were measured using a Hilger and Watts medical stereometer. This method was checked with test specimens, namely an osteotomised pelvis in which one acetabulum could be rotated and an osteotomised femur in which the whole upper portion could be rotated against the shaft. Measurements made on the acetabulum and its radiographs showed a correlation coefficient of 0.9838 over the range 0 to 30 degrees of anteversion, with a mean error +2.54 degrees and a standard deviation of +/- 1.52 degrees (n = 21). For the femoral neck, over the range from 10 degrees of retroversion to 80 degrees of anteversion, the correlation coefficient was 0.9979, the mean error +2.46 and the standard deviation +/- 1.48 degrees (n = 30).