header advert
Results 1 - 4 of 4
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 4 - 4
7 Aug 2023
Khaleeq T Saeed AZ Ahmed U Ajula R Boutefnouchet T D'Alessandro P Malik S
Full Access

Abstract

Customised individually made implants(CIM) total knee arthroplasty(TKA) are custom-made to better fit patients native anatomy and aim to improve outcomes which can be variable with conventional off-the-shelf(OTS).

A systematic review and meta-analysis was conducted searching the MEDLINE and Embase databases. Studies reporting on patient reported outcome measures, clinical or radiological outcomes were included.

23 studies satisfied the search criteria (case-control studies14, case series8, cross-sectional studies1). There were 2,856(CIM) and 1,877(OTS) implants. The overall revision-rate was higher in CIM 5.9%vs3.7%OTS [OR 1.46(95% CI 0.82–2.62)]. MUA was higher in the CIM group 2.2%vs.1.1%OTS [OR 2.95(95% CI 0.95–9.13)] and overall complications rate was also higher in the CIM group 5% vs. 4.5%OTS [OR 1.45(95% CI 0.53–3.96)]. LOS was significantly shorter in the CIM group 2.9 days vs. 3.5 days [MD −0.51(95% CI −0.82–0.20)]. Pooled analysis for KSS showed no difference between CIM and OTS groups(Knee=90.5 vs. 90.6 [MD-0.27,(95% CI −4.27–3.73)] and Function=86.1 vs. 90.6[MD 1.51 (95% CI −3.69–6.70)] component of the scores. There was no significant difference in post-operative ROM between CIM and OTS groups 117.3° vs. 115.0° [MD 0.02,(95% CI −1.70–1.74)].

CIM TKAs has theoretical benefits over OTS TKAs however in this review they were associated with higher complication, MUA and revision rates with no difference in outcome scores and no improvement in target alignment. The findings of this review does not support the use of CIM over OTS prosthesis in total knee arthroplasty.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 19 - 19
1 Jul 2022
Sweed T Boutefnouchet T Lim Z Amerasekera S Choudhary S Ashraf T
Full Access

Abstract

Introduction

There are several imaging-based measurements for patello-femoral height. Available methods rely predominantly on sagittal images. The latter can be misleading with sagittal oblique slices and when the patella is tilted and/or chronically subluxed. In this study we describe a simple method of patellar height measurement using axial MRI overlap.

Materials and methods

A retrospective observational analysis of 97 knees from 251 patients was conducted. Cases were selected following the exclusion of scans with fractures, massive effusion, patello-femoral pathology. Axial patello-trochlear overlap (APTO) was measured on the axial MRI images as follows: (1) Patellar length (P): expressed as the number of axial images showing patellar articular surface (2) Trochlear overlap (T): the number of axial images showing overlap between patellar articular surface and articular surface of lateral trochlea. APTO is the ratio T/P. All measurements were carried out independently and on two separate occasions by 6 raters. As a control conventional patello-trochlear index were measured for all patients by a senior musculoskeletal radiologist.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 63 - 63
1 Mar 2013
Boutefnouchet T Budair B Qadri Q
Full Access

Introduction

Delay, postponing and cancellation of hip fracture surgery leads to unnecessary starvation and adverse effects on patients and resources. Best Practice Tariffs (BPT) have been introduced to incentivise organisation into optimising the overall care for this type of injuries.

Methods

Retrospective observational analysis of all consecutive cases of hip fractures over a period of 18 months; this period spanned the introduction of BPT: 10 months before and 8 months after. Data on delay, postponing and cancellation of surgery were recorded and analysed.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 92 - 92
1 Jan 2013
Boutefnouchet T Ashraf M Budair B Porter K Tillman R
Full Access

A clinical evaluation of the effect of MRI scan to bring about a change in surgical management of elderly patients who present with hip fracture with no history of trauma or a suspicious looking lesion on x-rays. Many of these patients present with or without history of previous malignancy or bone disorder.

We evaluated that if the delay in treatment within 36 hours as per national guide lines is justified to benefit patients.

Methods

A clinical review of six hundred hip fracture patients where one hundred and four patients who had MRI scan of hip for fracture with either no history of trauma or a fracture with suspected pathological features with or without history of malignancy or bone disorder.

The final outcome of hundred patients who had MRI scans 32 male and 68 female with median age of 65 years. Four patients were excluded as were unable to tolerate the MRI scan.

Statistical analysis software SAS/STAT® was used to conduct data collation and analyses.

A further radiological analysis of MRI scans with positive lesion to the plain X-rays to correlate the finding of a lesion on femoral side on MRI scan to a lesion on acetabular side.

Results

Out of hundred patients who had MRI scan for a suspected metastatic or pathological lesion only 12 showed a metastatic lesion despite the fact 31 had previous history of malignancy, CI 4.03; 101.91, P < 0.0003. No primary lesion detected in any patient.

We also found if the acetabular side was not seen to be involved on pain x-ray, MRI scan did not detect any acetabular lesion, contingency coefficient 0.5632, P < .0001.