header advert
Results 1 - 20 of 22
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 811 - 819
1 Jul 2022
Galvain T Mantel J Kakade O Board TN

Aims

The aim of this study was to estimate the clinical and economic burden of dislocation following primary total hip arthroplasty (THA) in England.

Methods

This retrospective evaluation used data from the UK Clinical Practice Research Datalink database. Patients were eligible if they underwent a primary THA (index date) and had medical records available 90 days pre-index and 180 days post-index. Bilateral THAs were excluded. Healthcare costs and resource use were evaluated over two years. Changes (pre- vs post-THA) in generic quality of life (QoL) and joint-specific disability were evaluated. Propensity score matching controlled for baseline differences between patients with and without THA dislocation.


Bone & Joint Open
Vol. 3, Issue 5 | Pages 423 - 431
1 May 2022
Leong JWY Singhal R Whitehouse MR Howell JR Hamer A Khanduja V Board TN

Aims

The aim of this modified Delphi process was to create a structured Revision Hip Complexity Classification (RHCC) which can be used as a tool to help direct multidisciplinary team (MDT) discussions of complex cases in local or regional revision networks.

Methods

The RHCC was developed with the help of a steering group and an invitation through the British Hip Society (BHS) to members to apply, forming an expert panel of 35. We ran a mixed-method modified Delphi process (three rounds of questionnaires and one virtual meeting). Round 1 consisted of identifying the factors that govern the decision-making and complexities, with weighting given to factors considered most important by experts. Participants were asked to identify classification systems where relevant. Rounds 2 and 3 focused on grouping each factor into H1, H2, or H3, creating a hierarchy of complexity. This was followed by a virtual meeting in an attempt to achieve consensus on the factors which had not achieved consensus in preceding rounds.


Bone & Joint Open
Vol. 3, Issue 4 | Pages 291 - 301
4 Apr 2022
Holleyman RJ Lyman S Bankes MJK Board TN Conroy JL McBryde CW Andrade AJ Malviya A Khanduja V

Aims

This study uses prospective registry data to compare early patient outcomes following arthroscopic repair or debridement of the acetabular labrum.

Methods

Data on adult patients who underwent arthroscopic labral debridement or repair between 1 January 2012 and 31 July 2019 were extracted from the UK Non-Arthroplasty Hip Registry. Patients who underwent microfracture, osteophyte excision, or a concurrent extra-articular procedure were excluded. The EuroQol five-dimension (EQ-5D) and International Hip Outcome Tool 12 (iHOT-12) questionnaires were collected preoperatively and at six and 12 months post-operatively. Due to concerns over differential questionnaire non-response between the two groups, a combination of random sampling, propensity score matching, and pooled multivariable linear regression models were employed to compare iHOT-12 improvement.


Bone & Joint Research
Vol. 11, Issue 1 | Pages 23 - 25
17 Jan 2022
Matar HE Platt SR Bloch BV Board TN Porter ML Cameron HU James PJ


The Bone & Joint Journal
Vol. 103-B, Issue 12 | Pages 1774 - 1782
1 Dec 2021
Divecha HM O'Neill TW Lunt M Board TN

Aims

The aim of this study was to determine if uncemented acetabular polyethylene (PE) liner geometry, and lip size, influenced the risk of revision for instability or loosening.

Methods

A total of 202,511 primary total hip arthroplasties (THAs) with uncemented acetabular components were identified from the National Joint Registry (NJR) dataset between 2003 and 2017. The effect of liner geometry on the risk of revision for instability or loosening was investigated using competing risk regression analyses adjusting for age, sex, American Society of Anesthesiologists grade, indication, side, institution type, surgeon grade, surgical approach, head size, and polyethylene crosslinking. Stratified analyses by surgical approach were performed, including pairwise comparisons of liner geometries.


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1669 - 1677
1 Nov 2021
Divecha HM O'Neill TW Lunt M Board TN

Aims

To determine if primary cemented acetabular component geometry (long posterior wall (LPW), hooded, or offset reorientating) influences the risk of revision total hip arthroplasty (THA) for instability or loosening.

Methods

The National Joint Registry (NJR) dataset was analyzed for primary THAs performed between 2003 and 2017. A cohort of 224,874 cemented acetabular components were included. The effect of acetabular component geometry on the risk of revision for instability or for loosening was investigated using log-binomial regression adjusting for age, sex, American Society of Anesthesiologists grade, indication, side, institution type, operating surgeon grade, surgical approach, polyethylene crosslinking, and prosthetic head size. A competing risk survival analysis was performed with the competing risks being revision for other indications or death.


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 997 - 1002
1 Aug 2020
Leong JW Cook MJ O’Neill TW Board TN

Aims

The aim of this study was to investigate whether the use of antibiotic-loaded bone cement influenced the risk of revision surgery after primary total hip arthroplasty (THA) for osteoarthritis.

Methods

The study involved data collected by the National Joint Registry (NJR) for England and Wales, Northern Ireland and the Isle of Man between 1 September 2005 and 31 August 2017. Cox proportional hazards were used to investigate the association between use of antibiotic-loaded bone cement and the risk of revision due to prosthetic joint infection (PJI), with adjustments made for the year of the initial procedure, age at the time of surgery, sex, American Society of Anesthesiologists (ASA) grade, head size, and body mass index (BMI). We looked also at the association between use of antibiotic-loaded bone cement and the risk of revision due to aseptic loosening or osteolysis.


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1286 - 1289
1 Oct 2017
Rajpura A Board TN Siney PD Wynn Jones H Williams S Dabbs L Wroblewski BM

Aims

Our aim in this study was to describe a continuing review of 11 total hip arthroplasties using 22.225 mm Alumina ceramic femoral heads on a Charnley flanged femoral component, articulating against a silane crosslinked polyethylene.

Patients and Methods

Nine patients (11 THAs) were reviewed at a mean of 27.5 years (26 to 28) post-operatively. Outcome was assessed using the d’Aubigne and Postel, and Charnley scores and penetration was recorded on radiographs. In addition, the oxidation of a 29-year-old shelf-aged acetabular component was analysed.


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 147 - 156
1 Feb 2014
Rajpura A Kendoff D Board TN

We reviewed the literature on the currently available choices of bearing surface in total hip replacement (THR). We present a detailed description of the properties of articulating surfaces review the understanding of the advantages and disadvantages of existing bearing couples. Recent technological developments in the field of polyethylene and ceramics have altered the risk of fracture and the rate of wear, although the use of metal-on-metal bearings has largely fallen out of favour, owing to concerns about reactions to metal debris. As expected, all bearing surface combinations have advantages and disadvantages. A patient-based approach is recommended, balancing the risks of different options against an individual’s functional demands.

Cite this article: Bone Joint J 2014;96-B:147–56.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 410 - 410
1 Jul 2010
Nickinson RSJ Board TN Gambhir AK Porter ML Kay PR
Full Access

Aim: To identify the microbiology of infected knee arthroplasty, emerging patterns of resistance over the last decade, and suggest appropriate empirical treatment.

Methods: A retrospective analysis was conducted of 121 patients with microbiologically proven infection, who underwent revision TKA between 1994–2008. The causative organism was identified from microbiological samples and the corresponding sensitivities recorded. The data was then collated to determine the most common causative organisms, changing patterns of antibiotic resistance over the time frame, and the antibiotics currently most effective at treating deep infection. A theoretical model combining gentamicin with other antibiotics was used to determine the most effective antibiotics for use as empirical treatments.

Results: Coagulase negative Staphylococcus (CNS) was the most common causative organism (49%). Staphylococcus aureus (SA) accounted for 13% of cases. The prevalence of CNS appears to be increasing, while that of SA and other organisms is decreasing. Vancomycin and teicoplanin were the most effective antibiotics with overall sensitivity rates of 100% and 96% respectively. Levels of resistance were significantly higher among the antibiotics more commonly used in the community. Antimicrobial resistance was higher when the causative organism was CNS, suggesting that multi-drug resistant CNS is becoming a problem in knee arthroplasty. Our theoretical model showed that gentamicin combined with vancomycin would be the most effective empirical treatment.

Conclusion: Understanding the microbiology of deep infection of the knee allows surgeons to treat this complication as effectively as possible. Vancomycin and teicoplanin appear to be the most effective antimicrobials, with relative invulnerability to the development of resistance. Given the effectiveness of these antibiotics, the use of vancomycin in gentamicin bone cement, combined with IV teicoplanin potentially allows for infected knee arthoplasties to be treated with a one-stage procedure. The rational use of antibiotics may help limit the amount of antibiotic resistance which develops in the future.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 409 - 409
1 Jul 2010
Desai AS Karmegam A Board TN Raut VV
Full Access

Introduction: Stiffness is a disabling problem following TKR surgery. The overall incidence is 1–3%. Though multiple factors have been implicated in development of stiffness, it still remains an incompletely understood condition. Furthermore, opinion is divided about the efficacy, timing and the number of MUA’s post TKR surgery, as there are no definitive guidelines.

Aims & Objectives: The aim of this study was to assess the predisposing factors for stiffness following TKR surgery, to determine the efficacy of single and multiple manipulations and to investigate the most appropriate timing for manipulation.

Material & Methods: We retrospectively reviewed 86 patients who underwent manipulation for stiffness post-primary TKR surgery with at least one-year follow up. The number of manipulations, predisposing factors, the flexion gain at different intervals, final gain in flexion and range of movement was noted till the end of 1 year.

Results: Results were assessed by timing and number of MUA’s performed. Sixty five patients underwent single MUA and 21 had multiple MUA. At the end of one year the single MUA group showed 310 of sustained gain in flexion and in the multiple MUA group only 90 flexion gain was noted (p=0.003). MUA within 20 weeks of primary surgery showed 300 of flexion gain, whereas only 70 of flexion gain was seen when MUA was undertaken after 20 weeks (p=0.004). Patients on warfarin (9.5%) and with previous major surgeries to the knee prior to TKR (11.5%) had increase incidence of stiffness and poor flexion gain.

Conclusion: The timing of the 1st MUA is crucial, with better results achieved in MUA performed less than 20 weeks (particularly between 12–14 weeks) from primary surgery. Age, sex and type of disease do not influence the severity of stiffness in this study. There appears to be no added benefit in re-manipulation.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 411 - 411
1 Sep 2009
Sreekumar R Desai AS Board TN Raut VV
Full Access

Aims & Objectives: To assess whether the incidence of infection in Primary Total knee Arthroplasty is increased as a result of previous steroid infiltration into the knee joint.

Introduction: Steroid injection into the arthritic joint is a well-known modality of treatment of the arthritic joints. Its efficacy is well documented. Increased incidence of Infection secondary to steroid injection as compared to uninjected joints is reported in recent literature.

Material & Methods: 440 patients underwent Total Knee replacement (PFC SIGMA-Depuy) by senior author during 1997–2005 at Wrightington hospital. 90 patients had intraarticular steroid injection prior to surgery of which 45 patients had injection with in 1 year prior to surgery. All patients had at least one year follow up. Infection rate was assessed by case note, x-rays and microbiology review till last follow up.180 patients of a matched cohort who had total knee replacement without steroid injection were compared for infection rate.

Results: 2 cases of superficial infection were noted in Injection group and 5 cases of superficial infection in Non Injection group. No cases of Deep infection noted in either group. Stastical analysis showed no significant difference in incidence of infection in either group.

Conclusion: Steroids are useful adjuncts in the management of patients with arthritic joints. This study shows no increased incidence of infection in patients given steroid injection prior to arthroplasty.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 552 - 552
1 Aug 2008
Board TN Kendoff D Krettek C Hüfner T
Full Access

Introduction: Movement of the limb during computer aided arthroplasty may cause soft tissue impingement on the reference marker(RM) and consequently alter the spatial relationship between RM and bone with resulting inaccuracies in navigation. The purpose of this study was to investigate the effect of different degrees of soft tissue dissection on the stability of reference markers during limb movement.

Methods: The stability of both one- and two-pin RM systems inserted using three different levels of soft-tissue dissection was analysed in relation to a super-stable RM in fresh cadaver lower limbs. The spatial relationship of the two RMs was analysed using the VectorVision® system (BrainLAB, Germany) during multiple repetitions of four predefined limb movements. All tests were done with RMs inserted in both the distal-anterior femur and distal-lateral femur.

Results: Analysis of movements of the test RM in relation to the super-stable RM showed that rotations of less than 0.15o and translations of less than 0.4mm occurred in most test combinations. The combination that showed the greatest instability was when a stab incision was used to insert a pin in the distal/lateral femur (translation 0.73mm+/−0.05, rotation 0.25o+/− 0.05)(p< 0.001). This instability occurred in both single and double pin RMs(p=0.21).

Conclusions: RM pins can be placed in the anterior distal femur through simple stab incisions without resulting in significant soft tissue impingement during limb movement. If pins are placed in the lateral distal femur through stab incisions, impingement may occur from the fascia lata. Release of the fascia lata 1cm either side of the pin prevents significant impingement. Wide skin incision is unnecessary in any location.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 553 - 553
1 Aug 2008
Karva AR Board TN Kay PR Porter ML
Full Access

Introduction: Hip resurfacing arthroplasty is increasing in popularity, particularly in young and active patients. One unique advantage is retention of upper femoral bone stock with the hypothesis of easy revision should the resurfacing fail. The pupose of this study was to document the complexity or otherwise of our early experience with failed hip resurfacing.

Methods: We retrospectively reviewed all the patients who had revision surgery for failed hip resurfacing arthroplasty at our institution.

Results: Eleven patients with mean age of 52.8 years underwent revision of resurfacing at a mean time of 21.2 months following primary surgery. Revision was performed for deep infection in 4, cup loosening in 4 and 1 patient each for femoral neck fracture, avascular necrosis, and femoral loosening. For the 4 patients with cup loosening, the acetabular component was revised in 3 using a dysplasia Birmingham cup while 1 patient had both components revised. Of the 4 patients with deep infection, 3 had both components revised as one-stage revision with cemented components and 1 patient had a pseudarthosis. For the 3 cases with femoral loosening, neck fracture or avascular necrosis only the femoral component was revised using a cemented stem. Bone grafting was performed in 1 patient who had revision for loosening of acetabular cup with protrusio.

Conclusion: Acetabular failure appears to be equally common as femoral failure in resurfacing arthroplasty. Revision of both aseptic and septic failure appears to be relatively straightforward with primary implants used in all cases.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 565 - 566
1 Aug 2008
Board TN Citak M Kendoff D Krettek C Hüfner T
Full Access

In computer assisted orthopaedic surgery, rigid fixation of the Reference Marker (RM) system is essential for reliable computer guidance. A minimum shift of the RM can lead to substantial registration errors and inaccuracies in the navigation process. Various types of RM systems are available but there is little information regarding the relative stabilities of these systems. The aim of this study was to test the rotational stability of three commonly used RM systems.

One hundred and thirty Synbones and 15 cadavers were used to test the rotational stability of three different RM systems (Schanz’ screw, Brain-Lab MIRA and Stryker adjustment system). Using a specially developed testing device, the peak torque sustained by each RM system was assessed in various anatomical sites.

Comparison of means for Synbone showed that the BrainLab MIRATM system was the most stable (mean peak torque 5.60+/− 1.21 Nm) followed by the Stryker systemTM (2.53+/− 0.53 Nm) and the Schanz screw(0.77+/− 0.39 Nm)(p< 0.01). The order of stability in relation to anatomical site was femoral shaft, distal femur, tibial shaft, proximal tibia, anterior superior iliac spine, iliac crest and talus. Results from the cadaver experiments showed similar results. Bi-cortical fixation was superior to mono-cortical fixation in the femur(p< 0.01) but not the tibia(p=0.22).

The RM system is the vital link between bone and computer and as such the stability of the RM is paramount to the accuracy of the navigation process. In choosing RM systems for computer navigated surgery surgeons should be aware of their relative stability. Anatomical site of RM placement also affect the stability. Mono-cortical fixation is generally less stable than bi-cortical.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 302 - 303
1 Jul 2008
Board TN Gowaily K Hogg P Rooney P Kay PR
Full Access

Introduction: The success of impaction-grafting depends on mechanical stability and adequate bony incorporation of the graft. Full incorporation of this type of graft has been demonstrated histologically and depends on many factors including the biological activity of the graft. Bone morphogenic proteins (BMPs) are known to play a central role in bone formation and their presence reflects the biological activity of a graft material. The aim of this study was to determine the activity of fresh frozen femoral head (FFH) grafts by analysing BMP-7 release after milling and during strain imposed by the impaction process.

Methods: 10mm cancellous bone cubes were cut from 5 samples of FFH. The cubes were washed, centrifuged and washed again to remove the marrow contents. Specimens from each femoral head were allocated to five groups and subjected to strains of 0%, 20%, 40%, 60% and 80% with a material testing machine. The cubes were washed again and the wash fluid analysed for bmp-7 activity using a commercially available elisa kit. Additionally, samples of bone were taken after standard milling of FFH, washed and the fluid analysed for bmp-7 activity.

Results: bmp-7 activity was found to be present in all groups. Release of bmp-7 was found to increase with increasing strain in a linear relationship. At 80% strain the mean concentration of bmp-7 released (2.2 ng/g bone) was approximately double that released at 20% strain.

Discussion: activity of bmp-7 in FFH has not previously been demonstrated. This study shows that the freezing and storage of femoral heads allows some maintainance of biological activity. Furthermore we have shown that bmp-7 may be released from FFH cancellous bone in proportion to the strain applied to the bone. This may go some way to explaining the full bony incorporation often seen after impaction-grafting.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 370 - 370
1 Jul 2008
Alvi F Yang L Board TN
Full Access

Fine-wire fixators are a powerful tool in the management of acute fractures, non-unions, mal-unions and limb lengthening. The tension in the wires is very important in achieving stiffness of the whole fixator construct and current guidelines suggests tensioning wires to 900-1275N. There is evidence that during long term use the tension in the wires can reduce significantly. The effects of a reduction in tension on the fixator stiffness has been well characterised however the effect on the stresses imparted on the bone at the interface with the wire remain unknown. The main aim of this study was to identify any relationship between wire tension and wire-bone interface pressure.

An experimental system utilizing artificial cancellous bone mounted on a tensioned 2mm wire and then loaded by a material testing machine was employed. Pressure sensitive film allowed determination of interface stresses. The experiment was repeated at wire tensions of 600, 900 and 1200N. All other variables were kept the same during testing.

The highest pressures were found closest to the wire. At 1200N the peak pressures were 6-8 MPa, at 900N of tension the pressures rose to 8-10 MPa and at 600N pressures up to 14 MPa were observed. Deeper in the bone the pressures observed at 600N tension were double that seen at 1200N.

This is the first characterisation of the relationship between interface pressure and wire tension in fine-wire fixators. At 1200N the highest pressures are less than the compressive yield strength of cancellous bone whereas at both 600 and 900N pressures are greater than the yield which may lead to loosening. We therefore conclude that a tension of 1200N be employed when applying fine-wire fixators and during long term treatments the tensions should be regularly monitored to prevent loss of tension.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 821 - 824
1 Jun 2008
Board TN Rooney P Kay PR

In order to investigate the osteoinductive properties of allograft used in impaction grafting and the effect of strain during impaction on these properties, we designed an in vitro experiment to measure strain-related release of bone morphogenetic protein-7 (BMP-7) from fresh-frozen femoral head allograft. A total of 40 10 mm cubes of cancellous bone were cut from ten samples of fresh-frozen femoral head. The marrow was removed from the cubes and the baseline concentrations of BMP-7 were measured. Specimens from each femoral head were allocated to four groups and subjected to different compressive strains with a material testing machine, after which BMP-7 activity was reassessed. It was present in all groups. There was a linear increase of 102.1 pg/g (95% confidence interval 68.6 to 135.6) BMP-7 for each 10% increase in strain. At 80% strain the mean concentration of BMP-7 released (830.3 pg/g bone) was approximately four times that released at 20% strain. Activity of BMP-7 in fresh-frozen allograft has not previously been demonstrated. This study shows that the freezing and storage of femoral heads allows some maintenance of biological activity, and that impaction grafting provides a source of osteoinductive bone for remodelling.

We have shown that BMP-7 is released from fresh-frozen femoral head cancellous bone in proportion to the strain applied to the bone. This suggests that the impaction process itself may contribute to the biological process of remodelling and bony incorporation.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 668 - 673
1 May 2008
Karva AR Board TN Porter ML

We present a 25-year-old patient with juvenile rheumatoid arthritis and ankylosis of both hips and both knees treated by staged bilateral hip and knee arthroplasty. She was followed up for 18 months. We discuss the pre-operative planning, surgical details and post-operative rehabilitation.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 434 - 440
1 Apr 2007
Board TN Karva A Board RE Gambhir AK Porter ML

Heterotopic ossification following joint replacement in the lower limb occurs in 3% to 90% of cases. Higher grades of heterotopic ossification can result in significant limitation of function and can negate the benefits of joint replacement. The understanding of the pathophysiology of this condition has improved in recent years. It would appear to be related to a combination of systemic and local factors, including over-expression of bone morphogenetic protein-4. There is currently little evidence to support the routine use of prophylaxis for heterotopic ossification in arthroplasty patients, but prophylaxis is recommended by some for high-risk patients. Radiotherapy given as one dose of 7 Gy to 8 Gy, either pre-operatively (< four hours before) or post-operatively (within 72 hours of surgery), appears to be more effective than indometacin therapy (75 mg daily for six weeks). In cases of prophylaxis against recurrent heterotopic ossification following excision, recent work has suggested that a combination of radiotherapy and indometacin is effective. Advances in our understanding of this condition may permit the development of newer, safer treatment modalities.